Category Parameter Specification
Input Characteristics Input Voltage 100 - 240 VAC (Wide Range)
Input Frequency 50 / 60 Hz
Input Current Max. 0.9 A @ 100 VAC
Inrush Current Limiting Yes (NTC Thermistor)
Output Characteristics Output Voltage 24 V DC (Note: P1-32/E typically refers to the 24V model)
Voltage Adjustment Range ~22 - 26.4 V DC (via potentiometer)
Rated Output Current 1.3 A (for 24V model)
Rated Output Power 32 W
Efficiency Typically > 81%
Ripple and Noise < 150 mVpp
Redundancy & Monitoring Redundancy Function Integrated OR-ing diode for parallel operation
Signal Contact DC-OK relay contact (floating, 24V DC / 1A max.) for monitoring output status
Protection & Safety Overload Protection Electronic, auto-recovery (105% - 150% of Iout)
Overvoltage Protection Electronic, auto-recovery
Standards CE, cULus Listed
Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C)
Storage Temperature -40 °C to +85 °C
Cooling Method Fanless (Convection)
Mounting Standard 35 mm DIN Rail
Enclosure Protection IP20
Connections Screw Terminals
Category Parameter Specification
Display Screen Size 4-inch TFT LCD
Resolution 480 x 272 pixels
Color Depth 65K colors
Touch Screen Resistive
Hardware & Performance Processor ARM-based
Memory (User) Typically 8 MB for projects, recipes, data logs
Integrated I/O Digital Inputs: 4 x 24V DC
Digital Outputs: 4 x 24V DC, 0.5A (PNP)
Analog Input: 1 x 0-10V / 0-20mA
Integrated Safety Safety Inputs: 2 x (for e.g., emergency stop, safety gates)
Safety Outputs: 2 x (for e.g., safe torque off) - Compliant with SIL 2 / PL c
Communication Interfaces Ethernet Port 1 x 10/100 Mbit/s (for programming, HMI communication, and PLC networking)
Fieldbus PROFINET and/or EtherNet/IP (configurable as controller or device)
Serial Port 1 x RS-485/422
USB Port 1 x USB 2.0 Host (for connecting keyboard, mouse, or for data transfer)
Software Integrated PLC Runtime Eaton's SPC (Smart Process Controller) or SPS (Smart Programmable Controller)
Programming Software Eaton XVS software package (for HMI design, standard and safety logic programming)
Included License Pre-installed runtime license for the integrated PLC and HMI (SW suffix indicates this)
Electrical Supply Voltage 24 V DC (typical range: 19.2 - 28.8 V DC)
Power Consumption Typically 15-20 W
Environmental & Mechanical Protection Rating Front: IP65 (dust-tight and protected against water jets)
Rear: IP20
Mounting Panel Mount (Cut-out dimensions required)
Operating Temperature 0 °C to +55 °C
Category Parameter Specification
Application Protected Circuit Analog signals (e.g., 4-20 mA)
Connection In-series with the signal line
Electrical Characteristics Nominal Voltage 8 V DC
Max. Operating Voltage 12 V DC
Nominal Current ≤ 250 mA
Voltage Drop Typically < 1 V
Surge Protection Performance Test Waveform (IEC 61643-21) 1.2/50 μs (Voltage) - 8/20 μs (Current)
Nominal Discharge Current (In) 5 kA (8/20 μs)
Max. Discharge Current (Imax) 10 kA (8/20 μs)
Protection Level (Up) < 25 V (at In = 5 kA, 8/20 μs)
General Data Number of Channels 1
Connection Type Screw terminals
Mounting 35 mm DIN Rail
Housing Material Plastic (PA 6.6)
Operating Temperature -40 °C to +80 °C
Standards / Approvals IEC 61643-21, CE
Category Parameter Specification
Application Protected Circuit 2-wire Analog signals (e.g., 4-20 mA loops)
Connection In-series with the signal line
Electrical Characteristics Nominal Voltage 8 V DC
Max. Continuous Operating Voltage Uc 12 V DC
Nominal Current ≤ 250 mA
Voltage Drop Typically < 1 V
Insertion Loss Typically negligible
Surge Protection Performance Test Waveform (IEC 61643-21) 1.2/50 μs (Voltage) - 8/20 μs (Current)
Nominal Discharge Current (In) 5 kA (8/20 μs)
Max. Discharge Current (Imax) 10 kA (8/20 μs)
Protection Level (Up) < 25 V (at In = 5 kA, 8/20 μs)
General Data Number of Poles / Channels 2 (for series connection in one signal loop)
Connection Type Screw terminals
Mounting 35 mm DIN Rail
Housing Material Plastic
Operating Temperature -40 °C to +80 °C
Standards / Approvals IEC 61643-21, CE
Category Parameter Specification / Typical Value
Application & Configuration Protected Circuit Signal circuits (e.g., 4-20 mA, digital I/O)
Circuit Configuration 2-pole (Line-to-Line and Line-to-Ground protection)
Connection In-series with the signal line
Electrical Characteristics Nominal Voltage 8 - 24 V DC (Typical for signal applications)
Max. Continuous Operating Voltage (Uc) ~30 V DC (Please verify in datasheet)
Nominal Current (In) Up to 250 mA (Suitable for most signal loops)
Voltage Drop < 1.5 V (Low, to minimize impact on the signal)
Surge Protection Performance Standards Complies with IEC 61643-21
Nominal Discharge Current (In) 5 kA (8/20 μs waveform)
Max. Discharge Current (Imax) 10 kA (8/20 μs waveform)
Protection Level (Up) < 40 V (at In, typical for this class)
General Data Mounting 35 mm DIN Rail
Connection Type Screw terminals
Housing Material Plastic (PA 6.6)
Operating Temperature -40 °C to +80 °C
Status Indication None (This is a basic model without visual fault indicator)
Category Parameter Specification / Typical Value
Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing)
Input Frequency 50 / 60 Hz
Input Current Max. ~1.5 A @ 100 VAC
Inrush Current Limiting Yes
Output Characteristics Output Voltage Approx. 14 V DC (Critical: Must verify with datasheet)
Rated Output Current ~4.5 A (Calculated from 63W / 14V)
Rated Output Power 63 W
Efficiency Typically > 89% (High efficiency characteristic of P3 series)
Ripple and Noise Typically < 100 mVpp
Line Regulation < 0.5%
Load Regulation < 0.5%
Monitoring & Signaling Signal Contact (H11) DC-OK Relay (Floating changeover contact)
Contact Rating Typically 24V DC / 2A (or 230V AC / 2A)
Function Closes when output voltage is normal; opens on failure.
Protection & Safety Overload Protection Electronic, auto-recovery
Overvoltage Protection Electronic, auto-recovery
Short-Circuit Protection Yes, electronic with auto-recovery
Standards CE, cULus Listed, GL (Marine)
Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C)
Cooling Method Fanless (Convection)
Mounting Standard 35 mm DIN Rail
Protection Rating IP20
Connections Screw Terminals
Category Parameter Specification
Application Protected Circuit 2-wire Analog signals (e.g., 4-20 mA loops)
Connection In-series with the signal line
Electrical Characteristics Nominal Voltage 8 V DC
Max. Continuous Operating Voltage Uc 12 V DC
Nominal Current ≤ 250 mA
Voltage Drop Typically < 1 V
Insertion Loss Typically negligible
Surge Protection Performance Test Waveform (IEC 61643-21) 1.2/50 μs (Voltage) - 8/20 μs (Current)
Nominal Discharge Current (In) 5 kA (8/20 μs)
Max. Discharge Current (Imax) 10 kA (8/20 μs)
Protection Level (Up) < 25 V (at In = 5 kA, 8/20 μs)
General Data Number of Poles / Channels 2 (for series connection in one signal loop)
Connection Type Screw terminals
Mounting 35 mm DIN Rail
Housing Material Plastic
Operating Temperature -40 °C to +80 °C
Standards / Approvals IEC 61643-21, CE
Category Parameter Specification / Typical Value
Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing)
Input Frequency 50 / 60 Hz
Input Current Max. ~1.5 A @ 100 VAC
Inrush Current Limiting Yes, NTC thermistor
Output Characteristics Output Voltage Approx. 14 V DC (Critical: Must verify actual value with datasheet)
Rated Output Current ~4.5 A (Calculated from 63W / 14V)
Rated Output Power 63 W
Efficiency Typically > 89% (Characteristic of high-end P3 series)
Ripple and Noise Typically < 100 mVpp
Line Regulation < 0.5%
Load Regulation < 0.5%
Monitoring & Signaling (HI11 Option) Signal Contact DC-OK Relay (Floating changeover contact)
Contact Rating Typically 24V DC / 2A (or 230V AC / 2A)
Function Changes state when output voltage is within normal range; indicates power failure.
Protection & Safety Overload Protection Electronic, auto-recovery
Overvoltage Protection Electronic, auto-recovery
Short-Circuit Protection Yes, electronic with auto-recovery
Standards CE, cULus Listed, GL (Marine)
Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C)
Cooling Method Fanless (Convection)
Mounting Standard 35 mm DIN Rail
Protection Rating IP20
Connections Screw Terminals
Category Parameter Specification / Typical Value
Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing)
Input Frequency 50 / 60 Hz
Inrush Current Limiting Yes
Output Characteristics Output Voltage Likely 24 V DC (Must be verified with datasheet - other voltages like 12V or 48V are possible)
Rated Output Current ~2.6 A (if output is 24V)
Rated Output Power 63 W
Efficiency Typically > 89%
Ripple and Noise < 100 mVpp
Redundancy Function Redundancy Capability Yes, designed for parallel operation
Key Component Integrated OR-ing diode to prevent reverse current
Load Sharing Typically not active current sharing; relies on diode decoupling
Protection & Safety Overload Protection Electronic, auto-recovery
Overvoltage Protection Electronic, auto-recovery
Short-Circuit Protection Yes
Standards CE, cULus Listed
Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C)
Cooling Method Fanless (Convection)
Mounting Standard 35 mm DIN Rail
Connections Screw Terminals
Category Parameter Specification / Typical Value
Electrical Ratings Rated Voltage 300 VAC (3~ + PE)
Rated Current ~16 A (Critical: Must verify exact value with datasheet - common values are 16A, 20A, 30A for this form factor)
Frequency 50/60 Hz
Test Standards Safety Standards UL 60939, IEC 60939, EN 60939
EMC Standards Designed to meet CISPR 11/32, EN 55011/55032
Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz)
> 40 dB (Typical at 100 kHz)
Leakage Current Line to Ground Typically < 5 mA (at 250VAC, 50Hz)
General Data Number of Phases 3-Phase + Protective Earth (PE)
Connection Type Screw Terminals (for both line and load sides)
Mounting Through-hole or bracket mounting (panel mount)
Operating Temperature -25 °C to +100 °C
Housing Material Metal case (typically aluminum) for shielding