Category Parameter Specification / Typical Value
Electrical Ratings Rated Voltage 340 VAC (3~ + PE)
Rated Current 30 A
Frequency 50/60 Hz
Test Standards Safety Standards UL 60939, IEC 60939, EN 60939
EMC Standards Designed to meet CISPR 11/32, EN 55011/55032
Filter Performance Insertion Loss > 50 dB (Typical at 1 MHz)
> 40 dB (Typical at 100 kHz)
Leakage Current Line to Ground Typically < 10 mA (per phase)
General Data Number of Phases 3-Phase + Protective Earth (PE)
Connection Type Heavy-Duty Screw Terminals (MXL likely indicates this)
Mounting Through-hole or bracket mounting (panel mount)
Operating Temperature -25 °C to +100 °C
Housing Material Metal case (typically aluminum) for effective shielding
Category Parameter Specification / Typical Value
Electrical Ratings Rated Voltage 340 VAC (3~ + PE)
Rated Current 30 A
Frequency 50/60 Hz
Test Standards Safety Standards UL 60939, IEC 60939, EN 60939
EMC Standards Designed to meet CISPR 11/32, EN 55011/55032
Filter Performance Insertion Loss > 50 dB (Typical at 1 MHz)
> 40 dB (Typical at 100 kHz)
Leakage Current Line to Ground Typically < 10 mA (per phase)
General Data Number of Phases 3-Phase + Protective Earth (PE)
Connection Type Screw Terminals (Specific type defined by "MX")
Mounting Through-hole or bracket mounting (panel mount)
Operating Temperature -25 °C to +100 °C
Housing Material Metal case (typically aluminum) for effective shielding
Category Parameter Specification / Typical Value
General Characteristics Module Type Digital Input (DI)
Number of Channels Typically 4 or 8 channels (Must verify with datasheet)
Connection Technology M12 Connectors (likely 4-pin)
Input Characteristics Input Voltage 24 V DC (Nominal)
Input Type Sinking/Sourcing (PNP/NPN compatible) - Universal
"1" Signal Level Typically 15...30 V DC
"0" Signal Level Typically -3...5 V DC
Input Current per Channel Typically 2...5 mA
Electrical Isolation Channel-to-Channel Yes, typically isolated
Channel-to-Bus Yes, typically isolated
Performance Update Time < 1 ms per channel (typical)
Status Indication LED per channel (for input status) and module status
General Data Backplane Bus Proprietary (for XSystem EC platform)
Supply Voltage (from backplane) 24 V DC
Operating Temperature 0 °C to +55 °C
Standards IEC 61131-2, UL 508
Category Parameter Specification / Typical Value
General Characteristics Module Type Relay Output
Number of Channels Typically 4 channels (Must verify with datasheet)
Connection Technology M12 Connectors
Output Characteristics Output Type Electromechanical Relay - Dry Contact (SPDT or NO/NC)
Contact Rating (Max.) Typically 2A @ 250V AC or 2A @ 30V DC (per channel)
Electrical Isolation Galvanic isolation between PLC logic and load (via relay)
Load Compatibility Load Types AC or DC loads (within rating), resistive, inductive, lamp loads
Control & Indication Control Signal 24V DC from the PLC backplane
Status Indication LED per channel (indicating output state)
General Data Backplane Bus Proprietary (for XSystem platform)
Supply Voltage (from backplane) 24 V DC (for logic)
Operating Temperature 0 °C to +55 °C
Electrical Life > 100,000 cycles (at rated load)
Mechanical Life > 10,000,000 cycles
Standards IEC 61131-2, UL 508
Category Parameter Specification / Typical Value
General Characteristics Module Type Digital Input (DI)
Number of Channels Typically 4 channels
Connection Technology M12 Connectors (likely 4-pin)
Input Characteristics Input Voltage 24 V DC (Nominal)
Input Type Sourcing (PNP) / High-side switching
"1" Signal Level Typically 15...30 V DC (High-level input)
"0" Signal Level Typically -3...5 V DC (Low-level input)
Input Current per Channel Typically 2...10 mA
Electrical Isolation Channel-to-Channel Yes, typically isolated
Channel-to-Bus Yes, typically isolated
Performance Update Time < 1 ms per channel (typical)
Filter Time Configurable (e.g., 0.1/0.5/1/3 ms) to suppress noise
Status Indication LED per channel (for input status)
General Data Backplane Bus Proprietary (for XSystem platform)
Supply Voltage (from backplane) 24 V DC
Operating Temperature 0 °C to +55 °C
Protection Rating (with connector) IP67
Standards IEC 61131-2, UL 508
Category Parameter Specification / Typical Value
General Characteristics Module Type Digital Input (DI)
Number of Channels 8 channels (Higher density is typical for D3 code)
Connection Technology M12 Connectors (likely multi-port)
Input Characteristics Input Voltage 24 V DC (Nominal)
Input Type Sourcing (PNP) / High-side switching
"1" Signal Level Typically 15...30 V DC
"0" Signal Level Typically -3...5 V DC
Input Current per Channel Typically 2...5 mA
Filter Time Configurable (e.g., 0.1/0.5/1/3 ms)
Electrical Isolation Channel-to-Channel Yes, typically in groups
Channel-to-Bus Yes
Performance Update Time < 1 ms per channel (typical)
Status Indication LED per channel (for input status)
General Data Backplane Bus Proprietary (for XSystem platform)
Supply Voltage (from backplane) 24 V DC
Operating Temperature 0 °C to +55 °C
Protection Rating (with connector) IP67
Standards IEC 61131-2, UL 508
Category Parameter Specification / Typical Value
General Characteristics Module Type Digital Input (DI) with Diagnostics
Number of Channels Typically 4 channels
Connection Technology M12 Connectors
Input Characteristics Input Voltage 24 V DC (Nominal)
Input Type Sourcing (PNP) / High-side switching
"1" Signal Level Typically 15...30 V DC
"0" Signal Level Typically -3...5 V DC
Input Current per Channel Typically 2...10 mA
Diagnostic Functions (Key Feature) Diagnostic Capabilities • Wire-break/Open-circuit detection
• Short-circuit detection
• Overload detection
• Overvoltage detection
Diagnostic Indication Dual LED per channel (e.g., Green for status, Red/Yellow for fault)
Diagnostic Data Available via the fieldbus/backplane to the PLC
Electrical Isolation Channel-to-Channel Yes, typically isolated
Channel-to-Bus Yes
Performance Update Time < 1 ms per channel (typical)
General Data Backplane Bus Proprietary (for XSystem platform)
Supply Voltage (from backplane) 24 V DC
Operating Temperature 0 °C to +55 °C
Protection Rating (with connector) IP67
Standards IEC 61131-2, UL 508
Category Parameter Specification / Typical Value
General Characteristics Module Type Digital Mixed I/O (DI/DO) with Diagnostics
I/O Configuration Typically 2 DI + 2 DO or similar combination
Connection Technology M12 Connectors
Input Characteristics (DI) Input Type Sourcing (PNP) / 24V DC
Number of Inputs 2
"1" Signal Level 15...30 V DC
Input Current Typically 2...10 mA
Output Characteristics (DO) Output Type PNP (Sourcing) / 24V DC
Number of Outputs 2
Output Current (Max. per channel) Typically 0.5A or 2A (Must verify with datasheet)
Short-Circuit Protection Yes, electronic with diagnostics
Diagnostic Functions (Key Feature) Diagnostic Capabilities • Wire-break detection
• Short-circuit detection
• Overload detection
• Overvoltage detection (for both inputs and outputs)
Diagnostic Indication Dual LED per channel (for both DI and DO)
Diagnostic Data Available via the fieldbus/backplane to the PLC
General Data Backplane Bus Proprietary (for XSystem platform)
Supply Voltage (from backplane) 24 V DC
Operating Temperature 0 °C to +55 °C
Protection Rating (with connector) IP67
Standards IEC 61131-2, UL 508
Category Parameter Specification / Typical Value
Electrical Ratings Rated Voltage 340 VAC (3~ + PE)
Rated Current 70 A
Frequency 50/60 Hz
Test Standards Safety Standards UL 60939, IEC 60939, EN 60939
EMC Standards Designed to meet CISPR 11/32, EN 55011/55032
Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz)
> 45 dB (Typical at 100 kHz)
Leakage Current Line to Ground Typically < 15 mA (per phase)
General Data Number of Phases 3-Phase + Protective Earth (PE)
Connection Type Heavy-Duty Screw Terminals
Mounting Through-hole or bracket mounting (panel mount)
Operating Temperature -25 °C to +100 °C
Housing Material Metal case (typically aluminum) for effective shielding and heat dissipation
Category Parameter Specification / Typical Value
Electrical Ratings Rated Voltage 340 VAC (3~ + PE)
Rated Current 70 A
Frequency 50/60 Hz
Test Standards Safety Standards UL 60939, IEC 60939, EN 60939
EMC Standards Designed to meet CISPR 11/32, EN 55011/55032
Filter Performance Insertion Loss > 60 dB (Typical at 1 MHz)
> 45 dB (Typical at 100 kHz)
Leakage Current Line to Ground Typically < 15 mA (per phase)
General Data Number of Phases 3-Phase + Protective Earth (PE)
Connection Type Heavy-Duty Screw Terminals
Mounting Through-hole or bracket mounting (panel mount)
Operating Temperature -25 °C to +100 °C
Housing Material Metal case (typically aluminum) for effective shielding and heat dissipation