Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZMN1-A160
Rated Current 160 A (Frame Size)
Poles Typically 3-Pole (Pole configuration may vary, confirm with specific order code)
Rated Operational Voltage (Ue) Up to 690V AC
Rated Insulation Voltage (Ui) 800V AC
Trip Unit Type Type A - Adjustable Electronic Trip Unit
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
Breaking Capacity (Icu) High interrupting capacity (Typically 25 kA to 50 kA depending on specific voltage rating)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PKZM0 Series
Model Number PKZM0-4
Rated Operational Current (Ie) 4 A
Poles 3-Pole
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 750V AC
Utilization Category AC-3 (Squirrel cage motor: Starting, switching off during running)
Motor Power Rating (at 400V AC) 1.5 kW / 2 HP (Approximate)
Short-Circuit Breaking Capacity (Icu) Typically 6 kA or higher at 400V AC (Confirm with datasheet)
Trip Class Class 10
Operation Type Manual (Toggle Handle)
Mounting DIN Rail (35mm)
Standards Compliance IEC/EN 60947-4-1
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PKZM0 Series
Model Number PKZM0-6.3
Rated Operational Current (Ie) 6.3 A
Poles 3-Pole
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 750V AC
Utilization Category AC-3 (Squirrel cage motor: Starting, switching off during running)
Motor Power Rating (at 400V AC) ~2.2 kW / 3 HP (Approximate)
Short-Circuit Breaking Capacity (Icu) Typically 6 kA or higher at 400V AC (Confirm with datasheet)
Trip Class Class 10
Operation Type Manual (Toggle Handle)
Mounting DIN Rail (35mm)
Standards Compliance IEC/EN 60947-4-1
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, PKZM0 Series
Model Number PKZM0-32
Rated Operational Current (Ie) 32 A
Poles 3-Pole
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 750V AC
Utilization Category AC-3 (Squirrel cage motor: Starting, switching off during running)
Motor Power Rating (at 400V AC) ~15 kW / 20 HP (Approximate)
Short-Circuit Breaking Capacity (Icu) Typically 6 kA or higher at 400V AC (Confirm with datasheet)
Trip Class Class 10
Operation Type Manual (Toggle Handle)
Mounting DIN Rail (35mm)
Standards Compliance IEC/EN 60947-4-1
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, MFD Series
Model Number MFD-CP8-NT
Power Supply Voltage 24V DC (Typical for "C" variant)
Output Relay DPDT (2 CO) - 2 Changeover contacts
Contact Rating: Typically 8A @ 250V AC
Timing Ranges Multiple ranges selectable (e.g., from 0.1 seconds up to 100 hours)
Functions Multiple timing functions selectable (e.g., On-delay, Off-delay, Interval, Flasher, etc.)
Accuracy ±0.5% of set time ± 20 ms
Mounting DIN Rail (35mm)
Display / Indication Digital Display and LED Status Indicators
Standards Compliance IEC/EN 61812-1, UL 508, CSA C22.2 No. 14
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, T3 Series
Model Number T3-4-15682/I2/SVB
Rated Operational Current (Ie) 63 A (at AC-23)
Number of Poles 4-Pole (3 phases + neutral)
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 750V AC
Rated Impulse Withstand Voltage (Uimp) 8 kV
Utilization Categories AC-22 (Switching mixed resistive and inductive loads)
AC-23 (Switching motor loads)
Breaking Capacity Typically 30 kA (at 400V AC)
Auxiliary Contacts I2 - Specific auxiliary contact configuration (e.g., 1 NO + 1 NC)
Terminal Type SVB - Shrouded Terminal Barrier for enhanced safety
Operation Type Rotary Handle Operation
Mechanical Life ~ 20,000 operations
Electrical Life ~ 5,000 operations (at rated current)
Mounting DIN Rail (35mm)
Standards Compliance IEC/EN 60947-3
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, T0 Series
Model Number T0-3-15680/11/SVB
Rated Operational Current (Ie) 63 A (at AC-23)
Number of Poles 3-Pole
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 750V AC
Rated Impulse Withstand Voltage (Uimp) 8 kV
Utilization Categories AC-22 (Switching mixed resistive and inductive loads)
AC-23 (Switching motor loads)
Breaking Capacity Typically 30 kA (at 400V AC)
Auxiliary Contacts 11 - Specific auxiliary contact configuration (e.g., 1 NO contact)
Terminal Type SVB - Shrouded Terminal Barrier for enhanced safety
Operation Type Rotary Handle Operation
Mechanical Life ~ 20,000 operations
Electrical Life ~ 5,000 operations (at rated current)
Mounting DIN Rail (35mm)
Standards Compliance IEC/EN 60947-3
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, P3 Series
Model Number P3-63/EA/SVB/NL
Rated Current (In) 63 A
Number of Poles 3-Pole
Rated Operational Voltage (Ue) 400/415V AC (Three-Phase)
Rated Insulation Voltage (Ui) 500V AC
Breaking Capacity (Icn) Typically 10 kA (Please confirm with specific catalog)
Tripping Characteristic Type C (Instantaneous trip: 5-10 x In)
Auxiliary Function EA - Alarm Switch (Signals trip condition via a separate contact)
Terminal Type SVB - Shrouded Terminal Barrier (Finger Protection)
Variant NL - Specific variant or regional designation (e.g., for Netherlands market or specific certification)
Mounting Standard 35mm DIN Rail (EN 60715)
Standards Compliance IEC/EN 60898-1
Technical Parameters
Category Parameter Specification
Input Characteristics Input Voltage 100 - 240 VAC (Wide Range, Auto-Sensing)
Input Frequency 50 / 60 Hz
Input Current Max. 0.7 A @ 100 VAC
Inrush Current Limiting Yes (NTC Thermistor)
Output Characteristics Output Voltage 12 V DC
Voltage Adjustment Range ~11 - 13.2 V DC (via potentiometer)
Rated Output Current 2.1 A
Rated Output Power 25 W
Efficiency Typically > 80%
Ripple and Noise < 150 mVpp (typical)
Line Regulation < 1.0%
Load Regulation < 1.0%
Protection & Safety Overload Protection Electronic, auto-recovery (105% - 150% of Iout)
Overvoltage Protection Electronic, auto-recovery
Standards CE Marked
Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 50-60°C)
Storage Temperature -40 °C to +85 °C
Cooling Method Fanless (Convection)
Mounting Standard 35 mm DIN Rail
Enclosure Protection IP20 (Terminal Protection)
Connections Screw Terminals
Category Parameter Specification
Input Characteristics Input Voltage 100 - 240 VAC (Wide Range)
Input Frequency 50 / 60 Hz
Input Current Max. 0.9 A @ 100 VAC
Inrush Current Limiting Yes (NTC Thermistor)
Output Characteristics Output Voltage 12 V DC
Voltage Adjustment Range ~11 - 13.2 V DC (via potentiometer)
Rated Output Current 2.7 A
Rated Output Power 32 W
Efficiency Typically > 81%
Ripple and Noise < 150 mVpp
Line Regulation < 1.0%
Load Regulation < 1.0%
Protection & Safety Overload Protection Electronic, auto-recovery (105% - 150% of Iout)
Overvoltage Protection Electronic, auto-recovery
Standards CE, cULus Listed (Typically)
Environmental & Mechanical Operating Temperature -25 °C to +70 °C (with derating above 60°C)
Storage Temperature -40 °C to +85 °C
Cooling Method Fanless (Convection)
Mounting Standard 35 mm DIN Rail
Enclosure Protection IP20
Connections Screw Terminals
Safety Class Class I (Protective Earth connection required)