Key Parameters
Category Description / Value
Product Line Eaton DILM (Contactor) & Accessories (Timer)
Compatible Contactor DILM115C
Contactor Rated Operational Current (Iₑ) at AC-3 115 A (For squirrel-cage motors)
Contactor Rated Operational Power at AC-3 ~ 55 kW / 75 HP at 400V 50Hz
Contactor Poles 3 (Main Contacts)
Contactor Coil Control Voltage DC - The specific voltage (e.g., 24V, 110V DC) must be confirmed by the order code sticker on the contactor itself.
Module Type Timer Module
Timer Function Specific function (e.g., On-delay, Off-delay, Star-Delta) as defined by "GC" code.
Module Power Supply Derived from the main contactor coil circuit.
Mounting Snap-on mounting directly onto the DILM115C contactor.
Standards Compliance IEC/EN 60947-4-1
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 16 A
Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions
Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 25 A
Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions
Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 32 A
Number of Poles 1-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (e.g., 6 kA, 10 kA).
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Connection Screw terminals.
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 63 A
Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions
Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 6 A
Fuse Characteristic Time-Delay (Slow-Blow, Type C)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 13 A
Fuse Characteristic Quick-Acting (Fast-Blow, Type D)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 25 A
Fuse Characteristic Time-Delay (Slow-Blow, Type C)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Indicator Type Striker/Flag Indicator (as indicated by "AS" suffix)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse with Indicator
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 16 A
Fuse Characteristic Time-Delay (Slow-Blow, Type C)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/3" size code)
Fuse Size/Dimension 14 x 51 mm (DIN 43620)
Indicator Type Striker/Flag Indicator (as indicated by "AS" suffix)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse with Indicator
Key Parameters
Category Description / Value
Product Line Eaton FAZ (DIN Fuses)
Rated Current (Iₙ) 16 A
Fuse Characteristic Time-Delay (Slow-Blow, Type C)
Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code)
Fuse Size/Dimension 10 x 38 mm (DIN 43620)
Breaking Capacity High, typically 50 kA or more at 500V AC
Standards Compliance IEC 60269-1, UL 248-14 (or equivalent)
Fuse Type Cartridge Fuse