DILM115C
Key Parameters Category Description / Value Product Line Eaton DILM (Contactor) & Accessories (Timer) Compatible Contactor DILM115C Contactor Rated Operational Current (Iₑ) at AC-3 115 A (For squirrel-cage motors) Contactor Rated Operational Power at AC-3 ~ 55 kW / 75 HP at 400V 50Hz Contactor Poles 3 (Main Contacts) Contactor Coil Control Voltage DC - The specific voltage (e.g., 24V, 110V DC) must be confirmed by the order code sticker on the contactor itself. Module Type Timer Module Timer Function Specific function (e.g., On-delay, Off-delay, Star-Delta) as defined by "GC" code. Module Power Supply Derived from the main contactor coil circuit. Mounting Snap-on mounting directly onto the DILM115C contactor. Standards Compliance IEC/EN 60947-4-1

More details >> Request a Quote >>
EATON
PL9-D16
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 16 A Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
PL9-D25
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 25 A Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
PL10-C32
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 32 A Number of Poles 1-Pole Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (e.g., 6 kA, 10 kA). Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail). Connection Screw terminals.

More details >> Request a Quote >>
EATON
PL9X-D63
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 63 A Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
FAZ-C6/2
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 6 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>
EATON
FAZ-D13/2
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 13 A Fuse Characteristic Quick-Acting (Fast-Blow, Type D) Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>
EATON
FAZ-C25/2-AS
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 25 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Indicator Type Striker/Flag Indicator (as indicated by "AS" suffix) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse with Indicator

More details >> Request a Quote >>
EATON
FAZ-C16/3-AS
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 16 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 500 V AC (as indicated by "/3" size code) Fuse Size/Dimension 14 x 51 mm (DIN 43620) Indicator Type Striker/Flag Indicator (as indicated by "AS" suffix) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse with Indicator

More details >> Request a Quote >>
EATON
FAZ-C16/2
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 16 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>