PL9-C2/2
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 2 A Number of Poles 2-Pole Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 230 V AC (Single-Phase) Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
PL9-C40/3
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 40 A Number of Poles 3-Pole Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase) Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
PL9-C50/3
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 50 A Number of Poles 3-Pole Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase) Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
FAZ-C16/1
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 16 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 250 V AC (as indicated by "/1" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 250V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>
EATON
PL10-C20/3
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 20 A Number of Poles 3-Pole Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase) Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 6-10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
FAZ-C40/1
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 40 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 250 V AC (as indicated by "/1" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 250V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>
EATON
PL9X-D32
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 32 A Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
E6X-16
Key Parameters Category Description / Value Product Line Eaton E6X (Residual Current Devices) Rated Current (Iₙ) 16 A Number of Poles Typically 2-pole (1P+N) Rated Residual Operating Current (IΔn) 30 mA (standard sensitivity for personal protection) RCD Type AC Type (responds to alternating sinusoidal residual currents) Rated Operational Voltage (Uₑ) 230 V AC (Single-Phase) Breaking Capacity According to IEC/EN 61008 standard Standards Compliance IEC/EN 61008-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
FAZ-B16/2
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 16 A Fuse Characteristic Quick-Acting (Fast-Blow, Type B) Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>
EATON
PL10-C0.5/1N
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 0.5 A (500 mA) Number of Poles 1 Pole + Neutral (1P+N) Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 230 V AC (Single-Phase) Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>