EATON
Pl9-C4
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 4 A Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole versions Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 6-10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
PL9-C2
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 2 A Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole versions Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
PL9-C4/2
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 2 A Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole versions Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
PL9-C63/3
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 63 A Number of Poles 3-Pole Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ) Rated Operational Voltage (Uₑ) 400/415 V AC (Three-Phase) Rated Insulation Voltage (Uᵢ) 500 V Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA) Standards Compliance IEC/EN 60898-1 Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
PL9-C6-DC
Key Parameters Category Description / Value Product Line Eaton PL (Miniature Circuit Breakers) Rated Current (Iₙ) 6 A Number of Poles Typically 1-Pole or 2-Pole (must be confirmed from datasheet) Tripping Characteristic C-Curve Rated Operational Voltage (Uₑ) DC Voltage - The specific maximum DC voltage (e.g., 60V DC, 125V DC) must be confirmed from the device datasheet, as it differs from AC ratings. Breaking Capacity Rated for DC circuits according to relevant standards. Standards Compliance IEC/EN 60898-1 (or relevant DC standard) Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail). Connection Screw terminals.

More details >> Request a Quote >>
EATON
FAZT-C32/1N
Key Parameters Category Description / Value Product Line Eaton FAZT (Fuse Switch Disconnectors) Rated Current (Iₙ) 32 A (for switch and fuses) Number of Poles 1 Pole + Neutral (1P+N) Fuse Type Time-Delay (Type C), 10x38mm or 14x51mm DIN fuse (to be confirmed from datasheet) Rated Operational Voltage (Uₑ) 230/400 V AC Rated Insulation Voltage (Uᵢ) 500 V / 690 V Utilization Category AC-22B or AC-23B (for switching mixed loads including motor loads) Switch Function Load switching and isolation Protection Via external fuses Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail) Connection Screw terminals

More details >> Request a Quote >>
EATON
FAZ-B10/2
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 10 A Fuse Characteristic Quick-Acting (Fast-Blow, Type B) Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>
EATON
FAZ-C63/3
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 63 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 500 V AC (as indicated by "/3" size code) Fuse Size/Dimension 14 x 51 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>
EATON
FAZ-C10/2
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 10 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>
EATON
FAZ-C3/2
Key Parameters Category Description / Value Product Line Eaton FAZ (DIN Fuses) Rated Current (Iₙ) 3 A Fuse Characteristic Time-Delay (Slow-Blow, Type C) Rated Voltage (Uₑ) 500 V AC (as indicated by "/2" size code) Fuse Size/Dimension 10 x 38 mm (DIN 43620) Breaking Capacity High, typically 50 kA or more at 500V AC Standards Compliance IEC 60269-1, UL 248-14 (or equivalent) Fuse Type Cartridge Fuse

More details >> Request a Quote >>