Technical Parameters
Category Specification
Model BZZ-500-503-1189
Product Type Variable Displacement Axial Piston Pump
Displacement ~500 cm³/rev (cubic centimeters per revolution). This is a common interpretation of the "500" in the model number.
Pressure Rating
Maximum Continuous Pressure Typically in the range of 350 bar (≈ 5075 psi) or higher.
Peak Pressure Typically 400 bar (≈ 5800 psi) or higher.
Control Type Pressure Compensator Control (Standard). Other controls (e.g., load sensing, torque limiting) may be options.
Shaft Type Standard splined or keyed shaft.
Rotation Clockwise or Counter-Clockwise (as viewed from the shaft end).
Port Connection SAE or metric threaded ports.
Fluid Type Mineral-based or synthetic hydraulic oil.
Typical Applications
Mobile Equipment Main pump for excavators, cranes, etc.
Industrial Machinery Presses, injection molding machines.
Technical Parameters
Category Specification
Model XCEL45-125
Product Type Digital Servo Drive
Series XLC / XL Series
Frame Size 45
Input Power 125V AC (Single-Phase or Three-Phase). Must be verified with datasheet.
DC Bus Voltage Typically derived from the AC input.
Continuous Output Current Specific to the "-125" variant (e.g., 5A, 10A). Requires datasheet.
Peak Output Current Higher than the continuous current (e.g., 1.5 to 2 times continuous).
Communication EtherCAT, CANopen (typical for this series).
Control Modes Torque, Speed, Position (CSP, CSV, CST).
Feedback Support Supports high-resolution encoders (e.g., 24-bit multi-turn absolute).
Safety Function Integrated Safe Torque Off (STO).
Key Features
Advanced Control Auto-tuning, advanced filtering, friction compensation.
Diagnostics Comprehensive status monitoring and fault logging.
Technical Parameters
Category Specification
Part Number 233-3240-003
Product Type O-Ring / Sealing Gland
Industry Aerospace
Standard Likely conforms to an industry standard such as AS568 (for O-ring sizes) or a specific OEM standard.
Material Aerospace-grade elastomer such as Nitrile (Buna-N), Fluorocarbon (Viton), or Ethylene Propylene (EPDM). The exact material is determined by fluid compatibility requirements.
Size Defined by the part number. This includes:
Inside Diameter (ID) Precise measurement in inches or millimeters.
Cross-Section (CS) Precise measurement in inches or millimeters.
Temperature Range Specified for the material (e.g., -40°C to +120°C for Nitrile, much wider for specialized elastomers).
Fluid Compatibility Certified for use with specific fluids such as:
Hydraulic Fluids Skydrol, Mil-PRF-5606, HyJet
Fuels Jet A, Jet B
Lubricants Common aerospace lubricants.
Technical Parameters
Category Specification
Model SU45-800-21/26
Product Type Digital Servo Drive / Servo Amplifier
Series SU Series (S-Drive)
Frame Size 45
Continuous Output Current 8.0 A RMS
Peak Output Current Typically 16.0 A (for short duration, e.g., 1-2 seconds).
Supply Voltage (DC Bus) Typically 24 - 96 V DC (Low Voltage) or 200 - 480 V AC (High Voltage, via external rectifier). The "45" frame often corresponds to a high-voltage platform.
Communication EtherCAT, PROFIBUS-DP, or other fieldbus (defined by the firmware suffix 21/26).
Control Modes Torque, Speed, Position (CSP, CSV, CST).
Feedback Support Supports various feedback systems (e.g., EnDat, Hiperface, Resolver) as defined by the firmware.
Safety Function Integrated Safe Torque Off (STO).
Key Features
Advanced Control Auto-tuning, notch filters, adaptive control.
Diagnostics Comprehensive status monitoring and fault logging via software.
Technical Parameters
Category Specification
Model XCEL45-400
Product Type Digital Servo Drive
Series XLC / XL Series
Frame Size 45
Input Power 400V AC (3-Phase). Must be verified with datasheet.
DC Bus Voltage Typically derived from the AC input.
Continuous Output Current Specific to the "-400" variant (e.g., 5A, 10A). Requires datasheet.
Peak Output Current Higher than the continuous current (e.g., 1.5 to 2 times continuous).
Communication EtherCAT, CANopen (typical for this series).
Control Modes Torque, Speed, Position (CSP, CSV, CST).
Feedback Support Supports high-resolution encoders (e.g., 24-bit multi-turn absolute).
Safety Function Integrated Safe Torque Off (STO).
Key Features
Advanced Control Auto-tuning, advanced filtering, friction compensation.
Diagnostics Comprehensive status monitoring and fault logging.
Technical Parameters
Category Specification
Model EASY-E4-AC-8RE1
Product Type Programmable Logic Relay (PLR)
Power Supply 100-240V AC
Digital Inputs 12 (Can be expanded with additional modules)
Digital Outputs 8 Relay Outputs
Output Type Relay (electromechanical)
Output Contact Rating Typically 8A @ 250V AC
Program Memory Sufficient for complex relay-based applications (e.g., several KB)
Real-Time Clock Yes
Communication Integrated Ethernet port (for programming, HMI connection, and networking)
Programming Software EASY-SOFT
Programming Language Ladder Diagram (LD), Function Block Diagram (FBD)
Mounting DIN Rail Mount (35mm)
Key Features
Integrated Display Yes, for status monitoring and parameter setting
Expandability Can be expanded with EASY-E4 expansion I/O modules
Integrated Web Server Allows for remote monitoring via web browser
Technical Parameters
Category Specification
Model EMR6-T100-A-1
Product Type Solid-State Overload Relay
Rated Current Frame T100 (Requires external Current Transformers for motors up to 100A)
Motor Full Load Current Setting Adjustable via the integrated potentiometer, scaled according to the CT ratio.
Protection Functions
Overload Protection Yes (Class 10, 20, 30 selectable)
Phase Unbalance Protection Yes
Phase Loss Protection Yes
Jam (Locked Rotor) Protection Yes
Auxiliary Contacts 2 NO + 2 NC (for alarm and control signaling)
Control Supply Voltage Typically 24-240V AC/DC (wide range)
Status Indication LED indicators for Power, Trip, and Alarm conditions.
Mounting Designed to be mounted on the corresponding Eaton contactor or on a DIN rail.
Standards IEC/EN 60947-4-1, UL 508
Technical Parameters
Category Specification
Model EMR6-A300-C-1
Product Type Solid-State Overload Relay
Rated Current Frame A300 (Requires external Current Transformers for motors up to 300A)
Motor Full Load Current Setting Adjustable via the integrated potentiometer, scaled according to the CT ratio.
Protection Functions
Overload Protection Yes (Class 10, 20, 30 selectable)
Phase Unbalance Protection Yes
Phase Loss Protection Yes
Jam (Locked Rotor) Protection Yes
Auxiliary Contacts 2 NO + 2 NC (for alarm and control signaling)
Control Supply Voltage Typically 24-240V AC/DC (wide range)
Communication Option The "-C" likely indicates a communication module is pre-integrated or required (e.g., for DeviceNet, PROFIBUS-DP, or Modbus RTU).
Status Indication LED indicators for Power, Trip, and Alarm conditions.
Mounting Designed to be mounted on the corresponding Eaton contactor or on a DIN rail.
Standards IEC/EN 60947-4-1, UL 508
Technical Parameters
Category Specification
Model EMR6-W380-L-1
Product Type Solid-State Overload Relay
Rated Current Frame W380 (Requires external Current Transformers for motors up to 380A)
Motor Full Load Current Setting Adjustable via the integrated interface, scaled according to the CT ratio.
Protection Functions
Overload Protection Yes (with selectable trip class)
Phase Unbalance Protection Yes
Phase Loss Protection Yes
Jam (Locked Rotor) Protection Yes
Ground Fault Protection Optional or included depending on variant.
Auxiliary Contacts Multiple NO/NC contacts for alarm and control signaling.
Control Supply Voltage Wide range, typically 24-240V AC/DC.
Additional Features The "-L" may indicate features like an analog output (e.g., 4-20 mA) for motor current monitoring.
Status Indication LED indicators for Power, Trip, and Alarm conditions.
Mounting Designed for DIN rail or direct mounting.
Standards IEC/EN 60947-4-1, UL 508
Technical Parameters
Category Specification
Model EMR6-VM600-A-1
Product Type Solid-State Overload Relay
Rated Current Frame VM600 (Requires external Current Transformers for motors up to 600A)
Motor Full Load Current Setting Adjustable via the integrated interface, scaled according to the CT ratio.
Protection Functions
Overload Protection Yes (with selectable trip class)
Phase Unbalance Protection Yes
Phase Loss Protection Yes
Jam (Locked Rotor) Protection Yes
Auxiliary Contacts Typically 2 NO + 2 NC for alarm and control signaling.
Control Supply Voltage Wide range, typically 24-240V AC/DC.
Status Indication LED indicators for Power, Trip, and Alarm conditions.
Mounting Designed for DIN rail or direct mounting.
Standards IEC/EN 60947-4-1, UL 508