Parameter Specification
Product Model MTL5517
Product Line Eaton MTL Signal Conditioners & Isolators
Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area.
Output Signal Two independent, isolated 4-20 mA DC signals.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).
Parameter Specification / Inference
Product Model DPS2-20VF-020
Product Line Eaton DPS2 Digital Pressure Sensors
Sensor Type Digital Differential Pressure Transmitter
Pressure Range 0 to 2.0 in. w.c. (约 0 to 500 Pa)
Output Signal 0-10 V DC (2-wire)
Power Supply Typically 15-35 V DC
Accuracy Typically ±2% of reading or ±1% of full scale
Display Often includes a digital LCD display for local readout of pressure, velocity, and temperature.
Velocity Measurement Yes, can directly display air velocity (FPM or m/s) based on pressure input.
Response Time User-adjustable
Port Connections Two pressure ports (High and Low) for 1/4" OD tubing.
Electrical Connection Terminal block or pre-wired leads (to be confirmed)
Mounting Surface mount, duct mount, or 1/2" NPT conduit mount (depending on variant)
Operating Temperature 0°C to 50°C (32°F to 122°F)
Media Air and non-corrosive gases
Parameter Specification / Inference
Product Model P3-100/I5/SVB-SW/HI11
Product Line Eaton P3 Power Contactor
Rated Operational Current (Ie) ~100 A at AC-3, 400V (e.g., for controlling a ~55 kW motor at 400V)
Rated Operational Voltage (Ue) Up to 690 V AC
Number of Main Poles 3
Coil Voltage 400-415 V AC, 50 Hz
Auxiliary Contacts 1 NO (Normally Open) + 1 NC (Normally Closed)
Mounting Style Base Mounting with Screw Terminals (SVB)
Special Accessory Mechanical Interlock (HI11)
Electrical Life > 1 million operations (at rated load)
Mechanical Life > 10 million operations
Standards Compliance IEC 60947-4-1, UL 508
Parameter Specification
Product Model MTL5510
Product Line Eaton MTL Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated 4-20 mA DC signal.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).
Parameter Specification / Inference
Product Catalog Number 332726
Product Series AE (Heavy-Duty Oiltight Limit Switch)
Operator Type Lever Arm, Rotary (inferred from 62.2)
Contact Configuration 2 NO (Normally Open) + 2 NC (Normally Closed) (inferred from 5.P)
Rated Operational Current Typically 10 A @ 600 V AC (Common for these switches)
Electrical Life Typically 1-2 million operations (at rated load)
Mechanical Life Typically 10+ million operations
Enclosure Rating NEMA 4, 4X, 13; IP67 (Oiltight, Dust-tight, Water-resistant)
Housing Material Typically Zinc Die Cast
Actuator Material Steel or Thermoplastic roller
Terminal Type Screw terminals
Standards Compliance UL Listed, cULus, CE
Parameter Specification
Product Model MTL7796+
Product Line Eaton MTL Signal Conditioners & Isolators
Function 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal 4-20 mA DC (Isolated)
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC (for standard models)
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).
Parameter Specification
Product Model MTL4523
Product Line Eaton MTL Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated 4-20 mA DC signal.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).
Parameter Specification / Inference
Product Model EMS2-RO-T-3-SWD
Product Line Eaton EMS2 Occupancy Sensors
Sensor Technology Passive Infrared (PIR)
Mounting Type Ceiling Mount
Coverage Pattern 360° (Full Circle)
Coverage Range Diameter typically up to 15 meters (50 feet) (depending on mounting height)
Control Mode Manual-On / Vacancy Sensing with Auto-Off (SW)
Load Type Incandescent, Fluorescent, LED (Specific max load to be verified, e.g., 800W incandescent)
Input Voltage 120-277 V AC, 50/60 Hz
Adjustments Time Delay, Sensitivity (Lux) Level
Installation Height Recommended for ceilings typically 2.4 to 5 meters (8 to 16 feet) high.
Features
Vacancy Mode (Manual-On): Maximizes energy savings.
Stepped-Dim/Soft-Off: Gradually dims or turns off lights for user comfort.
Noise Immunity: Designed to ignore HVAC and other background disturbances.
Parameter Specification
Product Model MTL4544S
Product Line Eaton MTL4500+ Series Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated 4-20 mA DC signal.
Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher)
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (MUST be verified from datasheet):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm), Slimline design for high density.
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, etc.
Parameter Specification
Product Model MTL4521
Product Line Eaton MTL Signal Conditioners & Isolators
Function Single-channel, 2-Wire Transmitter Isolator & Power Supply
Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area.
Output Signal Isolated 4-20 mA DC signal.
Input/Output Isolation Galvanic Isolation between input, output, and power supply.
Power Supply Typically 20-30 V DC
Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx).
Entity Parameters (Example values, MUST be verified for design):
- Vmax (Ui): e.g., 28 V
- Imax (Ii): e.g., 93 mA
- Pi: e.g., 0.65 W
- Ci: e.g., 0 μF
- Li: e.g., 0 mH
Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA).
Line Fault Detection Yes, can detect open and short circuits in the field wiring.
Accuracy Typically better than ±0.1% of span.
Mounting DIN-Rail Mount (Standard 35 mm)
Operating Temperature -20°C to +60°C
Compliance & Certifications ATEX, IECEx, FM, CSA, NEPSI, etc. (Specific certifications depend on the product suffix).