Products
Products
home
EATON
MTL7765AC
Parameter Specification Product Model MTL7765AC Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Likely 100-240V AC (Inferred from "AC" suffix. MUST be verified from datasheet). Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C Compliance & Certifications ATEX, IECEx, FM, CSA, etc.

More details >> Request a Quote >>
EATON
MTL788+
Parameter Specification Product Model MTL788+ Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (Example values, MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C

More details >> Request a Quote >>
EATON
MTL7760AC
Parameter Specification Product Model MTL7760AC Product Line Eaton MTL Signal Conditioners & Isolators Function Dual-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers two independent 2-wire, 4-20 mA transmitters from a hazardous area. Output Signal Two independent, isolated 4-20 mA DC signals. Input/Output Isolation Galvanic Isolation between input, output, and power supply. Power Supply AC Input (e.g., 100-240V AC, specific range MUST be verified from datasheet). Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (MUST be verified for design): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C Compliance & Certifications ATEX, IECEx, FM, CSA, etc.

More details >> Request a Quote >>
EATON
PFR-W-30
Parameter Specification Product Model PFR-W-30 Product Line Eaton PFR Rated Current 30 A Phase Single Phase Rated Voltage Typically 480 V AC or 600 V AC Frequency 50/60 Hz Inductance Tolerance Typically ±10% Insulation Class Typically Class F or H Cooling Method Air-cooled, dry-type Mounting Suitable for chassis or panel mounting Standards Compliance UL, CSA, CE

More details >> Request a Quote >>
EATON
T0-2-15679/I1/SVB
Parameter Specification / Inference Product Model T0-2-15679/I1/SVB Product Line Eaton T0 Power Contactor Rated Operational Current (Ie) Typically up to ~25 A at AC-3, 400V Rated Operational Voltage (Ue) Up to 690 V AC Number of Main Poles 2 Coil Voltage 230 V AC, 50/60 Hz Auxiliary Contacts 1 NO (Normally Open) Mounting Style Base Mounting with Screw Terminals (SVB) Electrical Life > 1 million operations (at rated load) Mechanical Life > 10 million operations Standards Compliance IEC 60947-4-1, UL 508

More details >> Request a Quote >>
EATON
MTL5541S
Parameter Specification Product Model MTL5541S Product Line Eaton MTL5500+ Series Signal Conditioners & Isolators Function Single-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area. Output Signal Isolated 4-20 mA DC signal. Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher) Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (MUST be verified from datasheet): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, can detect open and short circuits in the field wiring. Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm), Slimline (S) design for high density. Operating Temperature -20°C to +60°C Compliance & Certifications ATEX, IECEx, FM, CSA, etc.

More details >> Request a Quote >>
EATON
13104RQD07
Parameter Specification / Inference Product Catalog Number 13104RQD07 Product Series 13104 (Heavy-Duty Oiltight Limit Switch) Operator Type Lever Arm, Rotary (inferred from RQ) Contact Configuration 1 NO (Normally Open) (inferred from D07) Rated Operational Current Typically 10 A @ 600 V AC (Common for these switches) Electrical Life Typically 1-2 million operations (at rated load) Mechanical Life Typically 10+ million operations Enclosure Rating NEMA 4, 4X, 13; IP67 (Oiltight, Dust-tight, Water-resistant) Housing Material Typically Zinc Die Cast Actuator Material Steel or Thermoplastic roller Terminal Type Screw terminals Standards Compliance UL Listed, cULus, CE

More details >> Request a Quote >>
EATON
LSM-11/RLA
Parameter Specification / Inference Product Model LSM-11/RLA Product Line Eaton Limit Switches Product Type Heavy-Duty Precision Limit Switch Contact Configuration 1 NO + 1 NC Actuator Type Rotating Lever Arm, Adjustable (RLA) Rated Operational Current Typically 10 A @ 600 V AC Electrical Life > 1 million operations Mechanical Life > 10 million operations Enclosure Rating NEMA 4, 4X, 13; IP67 Housing Material Typically Zinc Die Cast Terminal Type Screw terminals Standards Compliance UL Listed, cULus, CE

More details >> Request a Quote >>
EATON
LS-11
Parameter Specification / Inference Product Model LS-11 Product Line Eaton Heavy-Duty Limit Switch Contact Arrangement Typically 1 NO (Normally Open) + 1 NC (Normally Closed) - Single Circuit, Double Break Contact Operation Maintained Contact Switch Mechanism Slow Action (Snap-Action) Rated Operational Current 10 A @ 600 V AC (A common standard for this series) Electrical Life Typically 1 to 2 million operations (at rated load) Mechanical Life Typically 10 million operations Enclosure Rating NEMA 4, 4X, 6P, 13; IP67 (Dust-tight and protected against immersion) Housing Material Typically Zinc Die Cast Operating Head Plunger (as a standard configuration). Various other actuator types (e.g., roller lever, cat whisker) are available with different suffixes. Terminal Type Screw terminals Conduit Opening Standard ½" NPT Temperature Range Typically -20°C to +120°C (-4°F to +248°F) Standards Compliance UL Listed, cULus Listed, CE

More details >> Request a Quote >>
EATON
MTL5541A
Parameter Specification Product Model MTL5541A Product Line Eaton MTL5500+ Series Signal Conditioners & Isolators Function Single-channel, 2-Wire Transmitter Isolator & Power Supply Input Signal Accepts and powers a 2-wire, 4-20 mA transmitter from a hazardous area. Output Signal Isolated 4-20 mA DC signal. Input/Output/Power Isolation Galvanic Isolation (Typically 1.5 kV AC or higher) Power Supply Typically 20-30 V DC Intrinsic Safety (IS) Approval Yes. Certified for use in Hazardous Areas (e.g., ATEX, IECEx). Entity Parameters (MUST be verified from datasheet): - Vmax (Ui): e.g., 28 V - Imax (Ii): e.g., 93 mA - Pi: e.g., 0.65 W - Ci: e.g., 0 μF - Li: e.g., 0 mH Non-Incendive (NI) Approval Yes (for applicable standards like FM/CSA). Line Fault Detection Yes, with enhanced diagnostics (inferred from "A" suffix). Accuracy Typically better than ±0.1% of span. Mounting DIN-Rail Mount (Standard 35 mm) Operating Temperature -20°C to +60°C Compliance & Certifications ATEX, IECEx, FM, CSA, etc.

More details >> Request a Quote >>