Products
Products
home
ABB
CI854BK01
Key Features
✔ PROFIBUS DP-V1 Master Functionality

Full compliance with IEC 61158/61784 standards

Supports both cyclic and acyclic data communication

Automatic baud rate detection (9.6kbps to 12Mbps)

✔ Industrial-Grade Reliability

Operating temperature: -25°C to +60°C

500V galvanic isolation for noise immunity

Hot-swappable design (in redundant configurations)

✔ Advanced Diagnostics

LED status indicators for power, communication and errors

Comprehensive diagnostic capabilities

Supports PROFIBUS DP-V1 extended diagnostics

✔ Seamless Integration

Native compatibility with AC 800M controllers

Direct integration with System 800xA DCS

Supports up to 125 PROFIBUS DP slaves

Technical Specifications
Parameter Specification
Interface Type PROFIBUS DP-V1 (RS-485)
Connector 9-pin D-sub male
Communication Speed 9.6kbps - 12Mbps (auto-detect)
Power Supply 24V DC via backplane
Isolation 500V galvanic
Protection Class IP20
Certifications CE, UL, ATEX (optional)
Typical Applications
Process automation in oil & gas refineries

Manufacturing execution systems

Power plant control systems

Water and wastewater treatment

Material handling automation

More details >> Request a Quote >>
ABB
CI854AK01 3BSE030220R1
Key Features
✔ PROFIBUS DP-V1 Master Functionality

Full compliance with IEC 61158 Type 3 standard

Supports cyclic and acyclic data communication

Up to 244 bytes input/output data per slave

✔ High-Performance Communication

Auto-negotiating baud rates from 9.6 kbps to 12 Mbps

<1ms cycle time for fast response applications

✔ Industrial Reliability

Operating temperature: -25°C to +60°C

500V galvanic isolation for noise immunity

Hot-swappable in redundant configurations

✔ Advanced Diagnostics

Dual-color LED indicators for:

Power status

Bus activity

Error conditions

Comprehensive diagnostic data via controller

Technical Specifications
Parameter Specification
Manufacturer P/N 3BSE030220R1
Interface Type PROFIBUS DP-V1
Connector 9-pin D-sub male (RS-485)
Protocol Support DP-V0/V1
Max. Stations 125 slaves
Power Supply 24V DC via backplane
Isolation 500V galvanic
Certifications CE, UL, ATEX (optional)
Typical Applications
Process Automation (oil & gas, chemical plants)

Manufacturing Systems (automotive production)

Power Generation (turbine control)

Material Handling (conveyor systems)

Water Treatment (pump station control)

System Integration
Compatible Controllers:

ABB AC 800M (PM856, PM866, etc.)

System 800xA DCS

Field Device Connectivity:

PROFIBUS DP slaves (Siemens, ABB, etc.)

Remote I/O stations

Motor drives and actuators

More details >> Request a Quote >>
ABB
CI858K01 3BSE018135R1
Key Features
✔ Enhanced PROFIBUS DP-V1 Functionality

Full compliance with IEC 61158/61784 standards

Supports both cyclic and acyclic data exchange

Extended diagnostics for comprehensive network monitoring

✔ High-Speed Industrial Communication

Auto-negotiating baud rates from 9.6 kbps to 12 Mbps

<1ms cycle time for time-critical applications

Supports up to 244 bytes of I/O data per slave device

✔ Industrial-Strength Reliability

Operating temperature range: -25°C to +60°C

500V galvanic isolation for superior noise immunity

Hot-swappable design for maintenance without downtime

✔ Advanced Diagnostic Capabilities

Multi-color LED indicators for:

Power status

Network activity

Fault conditions

Detailed diagnostic data accessible via controller

Technical Specifications
Parameter Specification
Manufacturer P/N 3BSE018135R1
Interface Standard PROFIBUS DP-V1
Connector Type 9-pin D-sub (RS-485)
Max. Node Count 125 slaves
Power Supply 24V DC via backplane
Isolation 500V galvanic
Certifications CE, UL, ATEX (optional)
Typical Applications
Process Industries (oil refineries, chemical plants)

Power Generation (turbine control systems)

Manufacturing Automation (production lines)

Infrastructure Systems (water treatment plants)

Material Handling (conveyor belt systems)

System Integration
Controller Compatibility:

ABB AC 800M series (PM856, PM866, etc.)

System 800xA DCS

Field Device Support:

All standard PROFIBUS DP slaves

Remote I/O stations

Motor drives and actuators

Measurement devices

Configuration Tools:

ABB Control Builder Professional

Standard GSD/GSDML files for device integration

More details >> Request a Quote >>
ABB
AO845A 3BSE045584R1
Key Features
✔ High-Performance Analog Outputs

8 isolated channels (channel-to-channel and system isolation)

Configurable as 4-20mA, 0-20mA, or ±10V outputs

16-bit resolution for precise control

✔ Advanced Functionality

Individual channel configuration

Short-circuit protection on all current outputs

Open-circuit detection (for current outputs)

Overload protection (for voltage outputs)

✔ Industrial Reliability

Operating temperature: -25°C to +60°C

500V galvanic isolation

Hot-swappable in compatible systems

✔ Comprehensive Diagnostics

Per-channel LED status indicators

Detailed fault reporting via control system

Technical Specifications
Parameter Specification
Manufacturer P/N 3BSE045584R1
Output Type Current/Voltage (software configurable)
Current Output 4-20mA / 0-20mA (±0.1% accuracy)
Voltage Output ±10V (±0.1% accuracy)
Resolution 16-bit
Update Rate ≤1ms per channel
Load Impedance ≤500Ω (current), ≥1kΩ (voltage)
Power Supply 24V DC via backplane
Certifications CE, UL, ATEX (optional)
Typical Applications
Process Control Valves (position control)

Variable Speed Drives (speed reference)

Analog Actuators

Test & Measurement Systems

Batch Process Control

System Integration
Compatible With:

ABB AC 800M controllers

System 800xA DCS

S800 I/O base units

Configuration:

Programmed via ABB Control Builder

Supports Foundation Fieldbus or PROFIBUS PA networks

More details >> Request a Quote >>
ABB
CI854AK01
Key Features
✔ PROFIBUS DP-V1 Master Functionality

Full compliance with IEC 61158/61784 standards

Supports both cyclic and acyclic communication

Automatic baud rate detection (9.6kbps to 12Mbps)

✔ Industrial-Grade Reliability

Operating temperature: -25°C to +60°C

500V galvanic isolation for noise immunity

Hot-swappable in redundant configurations

✔ Advanced Diagnostics

LED indicators for power, status and communication

Comprehensive diagnostic capabilities

Supports PROFIBUS DP-V1 extended diagnostics

✔ Seamless Integration

Native compatibility with AC 800M controllers

Direct integration with System 800xA DCS

Supports up to 125 PROFIBUS DP slaves

Technical Specifications
Parameter Specification
Interface Type PROFIBUS DP-V1 (RS-485)
Connector 9-pin D-sub male
Communication Speed 9.6kbps - 12Mbps (auto-detect)
Power Supply 24V DC via backplane
Isolation 500V galvanic
Protection Class IP20
Certifications CE, UL, ATEX (optional)
Typical Applications
Process automation systems

Manufacturing execution systems

Power plant control

Water treatment plants

Material handling systems

More details >> Request a Quote >>
ABB
CI840A 3BSE041882R1
Key Features
✔ PROFIBUS DP-V1 Master Functionality

Full compliance with IEC 61158/61784 standards

Supports both cyclic and acyclic data communication

Automatic baud rate detection (9.6 kbps to 12 Mbps)

✔ Industrial Reliability

Operating temperature: -25°C to +60°C

500V galvanic isolation for noise immunity

Hot-swappable in redundant configurations

✔ Advanced Diagnostics

LED indicators for power, status, and communication

Comprehensive diagnostic capabilities

Supports PROFIBUS DP-V1 extended diagnostics

✔ Seamless Integration

Native compatibility with AC 800M controllers

Direct integration with System 800xA DCS

Supports up to 125 PROFIBUS DP slaves

Technical Specifications
Parameter Specification
Manufacturer P/N 3BSE041882R1
Interface Type PROFIBUS DP-V1
Connector 9-pin D-sub male
Communication RS-485
Power Supply 24V DC via backplane
Isolation 500V galvanic
Certifications CE, UL, ATEX (optional)
Typical Applications
Process Automation (oil & gas, chemical plants)

Manufacturing Systems (automotive production)

Power Generation (turbine control)

Water Treatment (pump station control)

Material Handling (conveyor systems)

More details >> Request a Quote >>
ABB
3BSE20510R1
Key Features
✔ PROFIBUS DP Master Functionality

Compliant with IEC 61158/61784 standards

Supports baud rates from 9.6 kbps to 12 Mbps

Automatic bus parameter detection

✔ Industrial-Grade Reliability

Operating temperature: -25°C to +60°C

500V galvanic isolation for noise immunity

Hot-swappable design for maintenance

✔ Advanced Diagnostics

LED status indicators for power and communication

Comprehensive fault detection and reporting

Supports PROFIBUS DP diagnostics

✔ Flexible Integration

Compatible with ABB AC 800M controllers

Supports System 800xA DCS

Connects up to 125 PROFIBUS DP slaves

Technical Specifications
Parameter Specification
Part Number 3BSE20510R1
Interface PROFIBUS DP (RS-485)
Connector 9-pin D-sub
Power Supply 24V DC
Isolation 500V
Certifications CE, UL
Typical Applications
Process automation systems

Manufacturing control

Power generation

Water treatment plants

Material handling systems

More details >> Request a Quote >>
ABB
DI880 3BSE028586R1
Key Features
✔ High-Density Input Configuration

32 isolated digital input channels

24V DC voltage sensing (sinking/sourcing configurable)

<1ms response time for fast signal processing

✔ Advanced Functionality

Individual channel diagnostics

Short-circuit and overload protection

Wire-break detection capability

✔ Industrial Reliability

Operating temperature: -25°C to +60°C

500V galvanic isolation (channel-to-system)

Hot-swappable in compatible systems

✔ Comprehensive Diagnostics

Per-channel LED status indicators

Detailed fault reporting via control system

Technical Specifications
Parameter Specification
Manufacturer P/N 3BSE028586R1
Input Type 24V DC (dry/wet contact)
Input Current 3-5mA typical
Isolation 500V between channels
Power Consumption 2.5W typical
Connection High-density terminal block
Certifications CE, UL, ATEX (optional)
Typical Applications
Process Automation (sensor monitoring, limit switches)

Manufacturing Systems (machine status inputs)

Power Generation (breaker status monitoring)

Safety Systems (emergency stop circuits)

Building Automation (access control systems)

More details >> Request a Quote >>
ABB
PM861AK01
Key Features:
Powerful Processing: Equipped with a high-speed processor for efficient execution of control algorithms.

Redundancy Support: Enables redundant configurations for mission-critical applications, ensuring system availability.

Multi-Protocol Communication: Supports industrial protocols like Profibus, Modbus, and OPC UA for seamless integration.

Large Memory Capacity: Ample storage for program code and data logging.

Robust Design: Built for harsh industrial environments with high resistance to electrical noise and temperature fluctuations.

Compatibility: Works with ABB’s S800 I/O modules and 800xA DCS for scalable automation solutions.

Typical Applications:
Process control in oil & gas, power generation, and chemical plants

Distributed control systems (DCS)

Supervisory control and data acquisition (SCADA)

More details >> Request a Quote >>
ABB
PM866AKO2
Key Features
✔ Dual-CPU Redundancy

1:1 hot standby configuration

Automatic switchover (<100ms)

99.999% availability for critical processes

✔ Powerful Processing Capability

1.1 GHz dual-core processor

1 GB RAM for complex control strategies

Supports up to 500,000 I/O points (system-wide)

✔ Industrial Communication

Dual Ethernet ports (10/100/1000 Mbps)

Supports PROFIBUS DP, Modbus TCP, OPC UA

Optional PROFINET, FF HSE communication

✔ Robust Industrial Design

Operating temperature: -40°C to +70°C

Vibration and shock resistant (IEC 60068-2-6/27)

IP20 protection (higher protection optional)

✔ Cybersecurity

IEC 62443 compliant

Secure boot and firmware validation

Role-based access control

Technical Specifications
Parameter Specification
Processor 1.1 GHz dual-core
Memory 1 GB RAM / 256 MB Flash
Redundancy 1:1 hot standby
I/O Capacity Up to 500,000 points
Communication Ethernet, PROFIBUS DP, Modbus TCP, OPC UA
Power Supply 24V DC (redundant)
Certifications CE, UL, ATEX (optional)
Typical Applications
Oil & Gas (refineries, pipelines, offshore platforms)

Power Generation (turbine control, SCADA)

Chemical Processing (batch and continuous processes)

Pharmaceutical (GMP manufacturing)

Water Treatment (plant-wide control systems)

More details >> Request a Quote >>
1 2
··· ···