Products
Products
home
EATON
T0-4-15682/I1/SVB-SW
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, T0 Series Model Number T0-4-15682/I1/SVB-SW Rated Operational Current (Ie) 63 A (at AC-22/AC-23) Number of Poles 4-Pole (3 phases + neutral) Rated Operational Voltage (Ue) 690V AC Rated Insulation Voltage (Ui) 750V AC Rated Impulse Withstand Voltage (Uimp) 8 kV Utilization Categories AC-22 (Switching mixed resistive and inductive loads) AC-23 (Switching motor loads) Auxiliary Contacts I1 - Specific auxiliary contact configuration (e.g., 1 NO + 1 NC) Terminal Type SVB-SW - Shrouded Terminal Barrier for switch disconnectors Operation Type Rotary Handle Operation Mechanical Life ~ 20,000 operations Electrical Life ~ 5,000 operations (at rated current) Mounting DIN Rail (35mm) Standards Compliance IEC/EN 60947-3

More details >> Request a Quote >>
EATON
T5B-3-8401
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, T5B Series Model Number T5B-3-8401 Rated Operational Current (Ie) 125 A (at AC-23) Number of Poles 3-Pole Rated Operational Voltage (Ue) 690V AC Rated Insulation Voltage (Ui) 750V AC Rated Impulse Withstand Voltage (Uimp) 8 kV Utilization Categories AC-22 (Switching mixed resistive and inductive loads) AC-23 (Switching motor loads) Breaking Capacity Typically 30 kA (at 400V AC) Operation Type Rotary Handle Operation Mechanical Life ~ 10,000 operations Electrical Life ~ 1,500 operations (at rated current) Mounting Panel Mount Standards Compliance IEC/EN 60947-3

More details >> Request a Quote >>
EATON
P1-32/I2/SVB
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, P1 Series (Domae) Model Number P1-32/I2/SVB Rated Current (In) 32 A Number of Poles 1-Pole Rated Operational Voltage (Ue) 230V AC (Single-Phase) Rated Insulation Voltage (Ui) 400V AC Breaking Capacity (Icn) Typically 6 kA / 10 kA (Please confirm with specific catalog) Tripping Characteristic Type C (Instantaneous trip: 5-10 x In) Auxiliary Contact I2 - Auxiliary Contact Configuration (e.g., 1 NO or 1 NC contact for remote signaling) Terminal Type SVB - Shrouded Terminal Barrier (Finger Protection) Mounting Standard 35mm DIN Rail (EN 60715) Standards Compliance IEC/EN 60898-1

More details >> Request a Quote >>
EATON
P1-32/2/SVB
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, P1 Series (Domae) Model Number P1-32/2/SVB Rated Current (In) 32 A Number of Poles 2-Pole (1P + N) Rated Operational Voltage (Ue) 230V AC (Single-Phase + Neutral) Rated Insulation Voltage (Ui) 400V AC Breaking Capacity (Icn) Typically 6 kA / 10 kA (Please confirm with specific catalog) Tripping Characteristic Type C (Instantaneous trip: 5-10 x In) Terminal Type SVB - Shrouded Terminal Barrier (Finger Protection) Mounting Standard 35mm DIN Rail (EN 60715) Standards Compliance IEC/EN 60898-1

More details >> Request a Quote >>
EATON
T0-4-8223/E
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, T0 Series Model Number T0-4-8223/E Rated Operational Current (Ie) 32 A (at AC-22/AC-23, typical for this code) Number of Poles 4-Pole (3 phases + neutral) Rated Operational Voltage (Ue) 690V AC Rated Insulation Voltage (Ui) 750V AC Rated Impulse Withstand Voltage (Uimp) 8 kV Utilization Categories AC-22 (Switching mixed resistive and inductive loads) AC-23 (Switching motor loads) Auxiliary Contacts E - Specific auxiliary contact configuration (e.g., 1 NO contact) Operation Type Rotary Handle Operation Mechanical Life ~ 20,000 operations Electrical Life ~ 5,000 operations (at rated current) Mounting DIN Rail (35mm) Standards Compliance IEC/EN 60947-3

More details >> Request a Quote >>
EATON
T0-4-15682/I1/SVB
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, T0 Series Model Number T0-4-15682/I1/SVB Rated Operational Current (Ie) 63 A (at AC-22/AC-23) Number of Poles 4-Pole (3 phases + neutral) Rated Operational Voltage (Ue) 690V AC Rated Insulation Voltage (Ui) 750V AC Rated Impulse Withstand Voltage (Uimp) 8 kV Utilization Categories AC-22 (Switching mixed resistive and inductive loads) AC-23 (Switching motor loads) Auxiliary Contacts I1 - Specific auxiliary contact configuration (e.g., 1 NO + 1 NC) Terminal Type SVB - Shrouded Terminal Barrier for enhanced safety Operation Type Rotary Handle Operation Mechanical Life ~ 20,000 operations Electrical Life ~ 5,000 operations (at rated current) Mounting DIN Rail (35mm) Standards Compliance IEC/EN 60947-3

More details >> Request a Quote >>
EATON
P3一63/V/SVB一SW/HI11
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, P3 Series Model Number P3-63/V/SVB-SW/HI11 Rated Current (In) 63 A Number of Poles 3-Pole Rated Operational Voltage (Ue) 400/415V AC (Three-Phase) Rated Insulation Voltage (Ui) 500V AC Breaking Capacity (Icn) Typically 10 kA (Please confirm with specific catalog) Tripping Characteristic Type C (Instantaneous trip: 5-10 x In) Terminal Type SVB-SW - Shrouded Terminal Barrier for Switch Disconnectors Operation Type V - Rotary Switch Handle (Manual operation) Control Module HI11 - Multi-function Time Relay Mounting Standard 35mm DIN Rail (EN 60715) Standards Compliance IEC/EN 60898-1 (MCB), IEC/EN 61812-1 (Timer)

More details >> Request a Quote >>
EATON
DIL4AMC145
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, DILA Series Model Number DILA4MC145 Rated Operational Current (Ie) 45 A at AC-3, 400V Thermal Current (Ith) 45 A Poles (Main Circuit) 4-Pole (Typically 3 main poles + 1 auxiliary power pole) Auxiliary Contacts Typically 1 NO (Normally Open) + 1 NC (Normally Closed) - Convertible Rated Operational Voltage (Ue) Up to 690V AC Control Coil Voltage DC operating coil (Specific voltage must be specified when ordering - e.g., 24V DC, 110V DC) Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running AC-1: Non-inductive or slightly inductive loads Motor Rating (at 400V AC) 22 kW / 30 HP (Approximate) Mechanical Life ~ 10-15 million operations Electrical Life (AC-3) ~ 1-2 million operations Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14 Terminal Type Cage Clamp / Screw Clamp

More details >> Request a Quote >>
EATON
ZMX3C-3-AX630
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, ZMX3C Series Model Number ZMX3C-3-AX630 Rated Current 630 A Number of Poles 3-Pole Rated Operational Voltage (Ue) Up to 690V AC Rated Insulation Voltage (Ui) 1000V AC Rated Ultimate Breaking Capacity (Icu) Typically 65 kA / 85 kA / 100 kA (depending on specific certification) Trip Unit Type AX - Advanced Electronic Trip Unit Protection Functions L - Long-time Delay (Overload) S - Short-time Delay (Short-Circuit) I - Instantaneous (Short-Circuit) G - Ground-Fault (Earth Leakage) Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
ZB150-50 XTOB050GC1
Technical Parameters Parameter Category Description / Value Brand & Series Eaton, ZB Series Model Number ZB150-50 XTOB050GC1 Output Voltage 50V DC Rated Output Power 150 W Rated Output Current 3.0 A Input Voltage Range 85-264V AC (Wide range, auto-sensing) Input Frequency Range 47-63 Hz Efficiency Typically >88% Power Factor (PF) Typically >0.95 Output Adjustment Range Typically ±10% (e.g., 45-55V DC) Connection Type Terminal Block Mounting DIN Rail (35mm) Protection Overload Protection, Overvoltage Protection, Short-Circuit Protection Cooling Method Convection cooling (Fanless design) Standards Compliance IEC/EN 61347-1, IEC/EN 61347-2-13, UL 1310, CSA C22.2 No. 223

More details >> Request a Quote >>
1 2
··· ···