Products
Products
home
EATON
ETS4-VS3
Key Parameters Category Description / Value Product Line Eaton ETS (Time Relays) Series ETS4 Function Star-Delta Changeover (with two independently adjustable times) Adjustable Times • T1 (Star Time): Adjustable range, e.g., 0.05s - 100h • T2 (Pause Time): Adjustable range, e.g., 0.05s - 100h Supply Voltage Wide range, typically 24-240V AC/DC (The exact range must be confirmed by the order code sticker on the device itself). Output Contacts Typically 2 Changeover (CO) Contacts (e.g., 2 NO/NC contacts) with a specific switching capacity. Time Setting Digital via rotary switches or pushbuttons with an LED display. Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail). Connection Screw terminals or spring-cage terminals. Standards Compliance IEC/EN 60947-5-1

More details >> Request a Quote >>
EATON
EASY822-DC-TC
Key Parameters Category Description / Value Product Line Eaton EASY (Smart Relays) Series EASY800 Model / CPU EASY822 Power Supply DC (Typical rating: 24 V DC. Must be verified on the device). Integrated Function PID Temperature Controller (as indicated by "TC") Digital Inputs 12 (The exact number and type - AC/DC sourcing/sinking - depends on the specific -DC variant). Digital Outputs 8 (Typically relay outputs). Analog Inputs 2 for temperature sensors (e.g., thermocouple Type J/K or Pt100/1000). Analog Output 1 for the PID control output (e.g., 0-10V or 0/4-20mA). Programming Via EASY-SOFT software or directly on the device using the built-in display and buttons. Display Integrated LCD for showing values, status, and messages. Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail). Communication Optional communication modules (e.g., for Ethernet, AS-Interface, IO-Link) can be added.

More details >> Request a Quote >>
EATON
NZM2-XDV-MODAN
Key Parameters Category Description / Value Product Line Eaton NZM2 Accessories Compatible Breakers NZM2 Motor Protection Circuit Breakers (e.g., NZM2-XV... series) Function Analog Setting Digitization Module Input Reads the physical position of the breaker's analog setting potentiometers. Output Digital data representing the breaker's current settings. Communication Interface Typically a System Interface (SI) or other proprietary digital bus used by Eaton's control systems (e.g., for integration with Eaton's XV-SI system interface modules). Mounting Designed to be mounted directly onto the compatible NZM2 breaker. Purpose • Setting Read-back: Allows a control system to read the actual protection settings configured on the breaker. • Condition Monitoring: Verifies that the settings have not been manually changed without the control system's knowledge. • Documentation: Provides digital documentation of protection parameters.

More details >> Request a Quote >>
EATON
DILM32-XTEY20
Key Parameters Category Description / Value Product Line Eaton DILM Accessories Compatible Contactors DILM32 Series Module Type Timer Module Timer Function Star-Delta Changeover (with adjustable time delay) Power Supply Derived from the main contactor coil circuit. Mounting Snap-on mounting directly onto the compatible DILM32 contactor. Connection Integrated connection via the snap-on mechanism; no external wiring required for power. Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14

More details >> Request a Quote >>
EATON
EASY621-DC-TC
Key Parameters Category Description / Value Product Line Eaton EASY (Smart Relays) Series EASY600 Model / CPU EASY621 Power Supply DC (Typical rating: 24 V DC. Must be verified on the device). Integrated Function PID Temperature Controller (as indicated by "TC") Digital Inputs 8 Digital Outputs 6 (Typically relay outputs). Analog Inputs 2 for temperature sensors (e.g., thermocouple Type J/K). Analog Output 1 for the PID control output (e.g., 0-10V or 0/4-20mA). Programming Via EASY-SOFT software or directly on the device using the built-in display and buttons. Display Integrated LCD for showing values, status, and messages. Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail). Communication Optional communication modules (e.g., for Ethernet, AS-Interface, IO-Link) can be added.

More details >> Request a Quote >>
EATON
EASY512-DC-RC
Key Parameters Category Description / Value Product Line Eaton EASY (Smart Relays) Series EASY500 Model / CPU EASY512 Power Supply DC (Typical rating: 24 V DC. Must be verified on the device). Digital Inputs 8 Digital Outputs 4 (Relay Contacts - as indicated by "RC"). Output Type Relay (Electromechanical) - Can switch AC or DC loads within rating. Programming Via EASY-SOFT software or directly on the device using the built-in display and buttons. Display Integrated LCD for showing values, status, and messages. Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail). Communication Optional communication modules (e.g., for Ethernet, AS-Interface, IO-Link) can be added.

More details >> Request a Quote >>
EATON
EASY820-DC-RC
Key Parameters Category Description / Value Product Line Eaton EASY (Smart Relays) Series EASY800 Model / CPU EASY820 Power Supply DC (Typical rating: 24 V DC. Must be verified on the device). Digital Inputs 12 Digital Outputs 8 (Relay Contacts - as indicated by "RC"). Output Type Relay (Electromechanical) - Can switch AC or DC loads within rating. Programming Via EASY-SOFT software or directly on the device using the built-in display and buttons. Display Integrated LCD for showing values, status, and messages. Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail). Communication Optional communication modules (e.g., for Ethernet, AS-Interface, IO-Link) can be added.

More details >> Request a Quote >>
EATON
EASY819-AC-RC
Key Parameters Category Description / Value Product Line Eaton EASY (Smart Relays) Series EASY800 Model / CPU EASY819 Power Supply AC (Common ratings: 120V AC or 230V AC. Must be verified on the device). Digital Inputs 12 Digital Outputs 8 (Relay Contacts - as indicated by "RC"). Output Type Relay (Electromechanical) - Can switch AC or DC loads within rating. Programming Via EASY-SOFT software or directly on the device using the built-in display and buttons. Display Integrated LCD for showing values, status, and messages. Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail). Communication Optional communication modules (e.g., for Ethernet, AS-Interface, IO-Link) can be added.

More details >> Request a Quote >>
EATON
EASY-E4-AC-16RE1
Key Parameters Category Description / Value Product Line Eaton EASY Expansion Modules Compatible Controllers EASY800 Series Base Units (e.g., EASY819, EASY820) Module Type Digital I/O Expansion Module Power Supply AC (Common ratings: 120V AC or 230V AC. Must be verified on the device). Total I/O Points 16 Digital Inputs 8 Digital Outputs 8 (Relay Contacts) Output Type Relay (Electromechanical) - Can switch AC or DC loads within rating. Connection to Base Unit Via a flat ribbon cable (usually included). Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).

More details >> Request a Quote >>
EATON
NZM4-XKM2S-1250
Key Parameters Category Description / Value Product Line Eaton NZM4 Model / Frame Size NZM4-XKM2 Release Type Electronic Trip Unit (as indicated by "S") - Adjustable protection settings. Rated Current (Iₙ) 1250 A (This is the frame rating. The operational current can be set within a range on the electronic trip unit). Poles 3-Pole & 4-Pole versions are available. Rated Operational Voltage (Uₑ) Up to 690 V AC, 50/60 Hz Rated Insulation Voltage (Uᵢ) 1000 V Rated Ultimate Short-Circuit Breaking Capacity (Iᶜᵘ) Very high, typically 100 kA or more at 400V AC (IEC 60947-2). The exact value must be verified from the technical data sheet. Trip Unit Functions • Long-time Delay (L) • Short-time Delay (S) • Instantaneous (I) • Ground-fault (G) protection (depending on the specific "S" variant). Mounting Fixed Mounting (for bolted installation in panels) or Draw-out Version (available as an option). Connection Primary power connections are typically made via busbars. Standards Compliance IEC/EN 60947-2 Auxiliary Contacts & Accessories Compatible with the full range of NZM4 accessories, such as auxiliary contacts, undervoltage release, shunt trip, and motor operator.

More details >> Request a Quote >>
1 2
··· ···