Parameter Specification
Product Model ZB12C-4 2.4-4A
Product Line Eaton ZB12 Miniature Circuit Breaker (MCB)
Number of Poles 1 Pole (1P)
Rated Current (In) 4 A
Tripping Characteristic C-Curve (Instantaneous tripping between 5 to 10 times In)
Rated Breaking Capacity (Icn) 4.5 kA
Rated Operational Voltage (Ue) 240/415 V AC
Standards IEC/EN 60898-1
Mounting DIN Rail Mount (35 mm)
Parameter Specification
Product Model ZB32C-6 4-6A
Product Line Eaton ZB32 Miniature Circuit Breaker (MCB)
Number of Poles 1 Pole (1P)
Rated Current (In) 6 A
Tripping Characteristic C-Curve (Instantaneous tripping between 5 to 10 times In)
Rated Breaking Capacity (Icn) 6 kA
Rated Operational Voltage (Ue) 230/400 V AC
Standards IEC/EN 60898-1
Mounting DIN Rail Mount (35 mm)
Parameter Specification
Manufacturer / Series Eaton, N-Series (Safety Switches)
Model Number NS2-250-NA
Product Type Safety Switch / Disconnect Switch
Pole Configuration 2-Pole
Rated Current 250 Amps
Voltage Rating 240V AC
HP Rating Typically 60 HP at 240V AC (Verifiy from datasheet)
Operation Toggle Handle (accesible through a door)
Type General Duty / Heavy Duty
Fuse Compatibility Designed for use with Class J, R, or T fuses. It is a non-fusible switch.
Mounting Flush Mounting
Standards Compliance UL 98, CSA C22.2
Parameter Specification
Manufacturer / Series Eaton, PDG Series (Electronic Motor Protector)
Model Number PDG33M0400B2NN
Product Type Electronic Motor Protector / Intelligent Overload Relay
Rated Current 400 A (The operational current range is set via the unit)
Setting Range Adjustable, typically covering a wide range up to 400A (e.g., 100-400A). Must verify from datasheet.
Rated Voltage Typically up to 690V AC
Protection Functions Comprehensive, including:
• Electronic Overload (with Thermal Memory)
• Phase Loss / Unbalance
• Undercurrent / Jam Protection
• Locked Rotor
• Earth Fault (Ground Fault)
Control Outputs Relay outputs for signaling faults, warnings, and controlling the contactor.
Communication Integrated communication ports (e.g., Modbus, DeviceNet, Profibus) for integration into control systems.
Power Supply Requires a separate control voltage (e.g., 24V DC or 110-230V AC).
Mounting DIN Rail Mount
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2
Parameter Specification
Manufacturer / Series Eaton, NZM Series
Model Number NZMB2-A125-NA
Product Type Miniature Circuit Breaker (MCB)
Pole Configuration 2-Pole
Rated Current (In) 125 A
Trip Curve Characteristic B Characteristic (General Purpose)
Rated Operational Voltage (Ue) 230/400V AC
Rated Insulation Voltage (Ui) 500V AC
Rated Frequency 50/60 Hz
Breaking Capacity (Icu) 10 kA at 230/400V AC (IEC 60898) / 25 kA at 400V AC (IEC 60947-2) *
Standards Compliance IEC 60898-1, IEC 60947-2
Mounting Fixed Mounting (on DIN Rail TH35-7.5)
Electrical Life 6,000 cycles
Mechanical Life 20,000 cycles
Ambient Temperature -25°C to +70°C (Derating above 40°C)
Torque Specification Typically 2.0 - 2.5 N·m
Parameter Specification
Manufacturer / Series Eaton, NZM Series
Model Number NZM1-AF80-NA
Product Type Arc Fault Detection Device (AFDD)
Pole Configuration 1-Pole
Rated Current (In) 80 A
Rated Voltage 230V AC
Rated Frequency 50/60 Hz
Breaking Capacity (Icn) 10 kA (IEC 60898-1) / 25 kA (IEC 60947-2) *
Arc Detection Yes (Detects both series and parallel arc faults)
Standards Compliance IEC 62606 (General requirements for AFDDs), IEC 60898-1
Mounting Fixed Mounting (on DIN Rail TH35-7.5)
Additional Features Typically includes a test button and an indicator for arc fault tripping.
Parameter Specification
Manufacturer / Series Eaton (Often part of the Moeller or DIL product line)
Model Number LZM3-4-A400
Product Type Thermal Overload Relay
Pole Configuration 3-Pole
Rated Operational Current (Ith) 400 A
Setting Current Range Adjustable, typically within a range such as 250 - 400 A (The exact range must be verified from the datasheet)
Trip Class Class 10 (Standard for general purpose motors)
Ambient Temperature Compensation Yes (Standard in most LZM relays)
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2
Mounting Snap-on attachment to a compatible contactor (e.g., Eaton DILM series)
Auxiliary Contacts The "-4-" likely specifies a configuration with 1 NO (Normally Open) + 1 NC (Normally Closed)
Reset Mode Manual reset (Automatic reset may be available as an option)
Ambient Temperature -25°C to +60°C
Parameter Specification
Manufacturer / Series Eaton, PDC Series (Combination Motor Controller)
Model Number PDC23G0250TAAS
Product Type Combination Motor Controller (Soft Starter + Protector)
Rated Current 250 Amps
Motor Power Rating Approximately 125 HP / 93 kW (at 460V AC) - Exact HP depends on voltage; verify from datasheet.
Voltage Rating Typically 200-575V AC, 3-Phase, 50/60 Hz
Short-Circuit Withstand High, typically 65 kA or 100 kA (Must verify from datasheet)
Control Method Digital, microprocessor-based solid-state soft starting
Key Features • Integrated Molded Case Switch (Disconnect)
• Solid-State Soft Start/Stop
• Advanced Motor Protection (Overload, Phase Loss, etc.)
• Diagnostic Capabilities
Communication Integrated communication capabilities (e.g., DeviceNet, Modbus) are typically standard.
Mounting Fixed Mounting
Standards Compliance UL 508, IEC 60947-4-2, CSA C22.2
Parameter Specification
Manufacturer / Series Eaton, NZM Series
Model Number NZMB1-A100-NA
Product Type Miniature Circuit Breaker (MCB)
Pole Configuration 1-Pole
Rated Current (In) 100 A
Trip Curve Characteristic B Characteristic (General Purpose)
Rated Operational Voltage (Ue) 230/400V AC
Rated Insulation Voltage (Ui) 500V AC
Rated Frequency 50/60 Hz
Breaking Capacity (Icu) 10 kA at 230/400V AC (IEC 60898) / 25 kA at 400V AC (IEC 60947-2) *
Standards Compliance IEC 60898-1, IEC 60947-2
Mounting Fixed Mounting (on DIN Rail TH35-7.5)
Electrical Life 6,000 cycles
Mechanical Life 20,000 cycles
Ambient Temperature -25°C to +70°C (Derating above 40°C)
Torque Specification Typically 2.0 - 2.5 N·m
Parameter Specification
Manufacturer / Series Eaton, NZM Series
Model Number NZM1-AF60-NA
Product Type Arc Fault Detection Device (AFDD)
Pole Configuration 1-Pole
Rated Current (In) 60 A
Rated Voltage 230V AC
Rated Frequency 50/60 Hz
Breaking Capacity (Icn) 10 kA (IEC 60898-1) / 25 kA (IEC 60947-2) *
Arc Detection Yes (Detects both series and parallel arc faults)
Standards Compliance IEC 62606 (General requirements for AFDDs), IEC 60898-1
Mounting Fixed Mounting (on DIN Rail TH35-7.5)
Additional Features Typically includes a test button and an indicator for arc fault tripping.