EATON
NZMH2-A100
Parameter Specification Manufacturer / Series Eaton, NZM Series Model Number NZMH2-A100 Product Type Miniature Circuit Breaker (MCB) Pole Configuration 2-Pole Rated Current (In) 100 A Trip Curve Characteristic H Characteristic (8-12 x In) Rated Operational Voltage (Ue) 230/400V AC Rated Insulation Voltage (Ui) 500V AC Rated Frequency 50/60 Hz Breaking Capacity (Icu) 10 kA at 230/400V AC (IEC 60898) / 25 kA at 400V AC (IEC 60947-2) * Standards Compliance IEC 60898-1, IEC 60947-2 Mounting Fixed Mounting (on DIN Rail TH35-7.5) Electrical Life 6,000 cycles Mechanical Life 20,000 cycles Ambient Temperature -25°C to +70°C (Derating above 40°C) Torque Specification Typically 2.0 - 2.5 N·m

More details >> Request a Quote >>
EATON
NZMH1-A100-AS
Parameter Specification Manufacturer / Series Eaton, NZM Series Model Number NZMH1-A100-AS Product Type Miniature Circuit Breaker (MCB) Pole Configuration 1-Pole Rated Current (In) 100 A Trip Curve Characteristic H Characteristic (High Inrush) Rated Operational Voltage (Ue) 230/400V AC Rated Insulation Voltage (Ui) 500V AC Rated Frequency 50/60 Hz Breaking Capacity (Icu) 10 kA at 230/400V AC (IEC 60898) / 25 kA at 400V AC (IEC 60947-2) * Standards Compliance IEC 60898-1, IEC 60947-2 Mounting Fixed Mounting (on DIN Rail TH35-7.5) Electrical Life 6,000 cycles Mechanical Life 20,000 cycles Ambient Temperature -25°C to +70°C (Derating above 40°C) Torque Specification Typically 2.0 - 2.5 N·m

More details >> Request a Quote >>
EATON
E2JM3250F
Parameter Specification / Decoding Manufacturer / Series Eaton, E2J Series Model Number E2JM3250F Product Type Multi-Function Timer Relay Mounting Style Panel-Mount (for DIN Rail) Supply Voltage Wide Range (e.g., 24-240V AC/DC) - Must verify from datasheet Time Range Up to 50 Seconds (selectable via dial) - Must verify from datasheet Timing Functions Multiple (e.g., On-Delay, Off-Delay, Interval, Flash) - Specific function defined by "F" Output Contacts DPDT (2 Form C) - Electromechanical Relay Contact Rating Typically 5A-10A at 250V AC - Must verify from datasheet Setting Method Analog Rotary Dial (Potentiometer) Indicator Power-On and Output-ON LEDs Standards CE, cULus (UL 508)

More details >> Request a Quote >>
EATON
HMCP400X5
Parameter Specification Manufacturer / Series Eaton, HMC Series Model Number HMCP400X5 Product Type Molded Case Circuit Breaker - Motor Circuit Protector (MCP) Pole Configuration 3-Pole (Standard for three-phase motor protection) Frame Size 400A Frame Rated Current 400 Amps (Frame Rating) Voltage Rating 600V AC Interrupting Rating 100 kA at 480V AC (Typical for this series - verify from datasheet) Trip Unit Type Instantaneous Magnetic Trip Only (MCP function) Trip Setting Factory-adjusted magnetic trip setting - "X5" defines the specific setting range Mounting Bolt-On (Lug Connection) Standards Compliance UL 489, CSA C22.2, IEC 60947-2

More details >> Request a Quote >>
EATON
HMCP250W5C
Parameter Specification Manufacturer / Series Eaton, HMC Series Model Number HMCP250W5C Product Type Molded Case Circuit Breaker - Motor Circuit Protector (MCP) Pole Configuration 3-Pole (Standard for motor protection) Frame Size 250A Frame Rated Current 250 Amps (Frame Rating) Voltage Rating 600V AC Interrupting Rating High, typically 65 kA or 100 kA at 480V AC (Must verify from datasheet) Trip Unit Type Instantaneous Magnetic Trip Only (MCP function) Trip Setting Factory-adjusted, typically adjustable over a range (e.g., 5x to 13x of the MCP setting) - "W5C" defines this specific setting. Mounting Bolt-On (Lug Connection) Standards Compliance UL 489, CSA C22.2

More details >> Request a Quote >>
EATON
HMCP250G5C
Parameter Specification Manufacturer / Series Eaton, HMC Series Model Number HMCP250G5C Product Type Molded Case Circuit Breaker - Motor Circuit Protector (MCP) Pole Configuration 3-Pole (Standard for motor protection) Frame Size 250A Frame Rated Current 250 Amps (Frame Rating) Voltage Rating 600V AC Interrupting Rating High, typically 65 kA or 100 kA at 480V AC (Must verify from datasheet) Trip Unit Type Instantaneous Magnetic Trip Only (MCP function) Trip Setting Factory-adjusted, typically adjustable over a range (e.g., 5x to 13x of the MCP setting) - "G5C" defines this specific setting. Mounting Bolt-On (Lug Connection) Standards Compliance UL 489, CSA C22.2

More details >> Request a Quote >>
EATON
HMCP250W5W
Parameter Specification Manufacturer / Series Eaton, HMC Series Model Number HMCP250W5W Product Type Molded Case Circuit Breaker - Motor Circuit Protector (MCP) Pole Configuration 3-Pole (Standard for motor protection) Frame Size 250A Frame Rated Current 250 Amps (Frame Rating) Voltage Rating 600V AC Interrupting Rating High, typically 65 kA or 100 kA at 480V AC (Must verify from datasheet) Trip Unit Type Instantaneous Magnetic Trip Only (MCP function) Trip Setting Factory-adjusted, typically adjustable over a range (e.g., 5x to 13x of the MCP setting) - "W5W" defines this specific setting. Mounting Bolt-On (Lug Connection) Standards Compliance UL 489, CSA C22.2

More details >> Request a Quote >>
EATON
LZMC2 160A
Parameter Specification Manufacturer / Series Eaton (Often part of the Moeller or IZM brand in some markets) Model Number LZMC2 160A (Full catalog number may include suffixes) Product Type Thermal Overload Relay Pole Configuration 2-Pole Rated Operational Current (Ith) 160 A Setting Current Range Adjustable, typically 100 - 160 A (The exact range must be verified from the datasheet) Trip Class Class 10 (Standard for general purpose motors) Ambient Compensation Yes (Standard feature) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 Mounting Snap-on attachment to a compatible contactor (e.g., Eaton DIL series) Auxiliary Contacts Typically 1 NO (Normally Open) + 1 NC (Normally Closed) Reset Mode Manual reset (Automatic reset may be available as an option) Ambient Temperature -25°C to +60°C (with compensation)

More details >> Request a Quote >>
EATON
NZMH1-A80
Parameter Specification Manufacturer / Series Eaton, NZM Series Model Number NZMH1-A80 Product Type Miniature Circuit Breaker (MCB) Pole Configuration 1-Pole Rated Current (In) 80 A Trip Curve Characteristic H Characteristic (High Inrush) Rated Operational Voltage (Ue) 230/400V AC Rated Insulation Voltage (Ui) 500V AC Rated Frequency 50/60 Hz Breaking Capacity (Icu) 10 kA at 230/400V AC (IEC 60898) / 25 kA at 400V AC (IEC 60947-2) * Standards Compliance IEC 60898-1, IEC 60947-2 Mounting Fixed Mounting (on DIN Rail TH35-7.5) Electrical Life 6,000 cycles Mechanical Life 20,000 cycles Ambient Temperature -25°C to +70°C (Derating above 40°C) Torque Specification Typically 2.0 - 2.5 N·m

More details >> Request a Quote >>
EATON
LZMC3-A320
Parameter Specification Manufacturer / Series Eaton (Often part of the Moeller or DIL product line) Model Number LZMC3-A320 Product Type Thermal Overload Relay Pole Configuration 3-Pole Rated Operational Current (Ith) 320 A Setting Current Range Adjustable, typically within a range such as 200 - 320 A (The exact range must be verified from the datasheet) Trip Class Class 10 (Standard for general purpose motors) Ambient Temperature Compensation Yes (Standard in most LZM relays) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 Mounting Snap-on attachment to a compatible contactor (e.g., Eaton DIL series) Auxiliary Contacts Typically at least 1 NO (Normally Open) and 1 NC (Normally Closed) Reset Mode Manual reset (Automatic reset may be available as an option) Ambient Temperature -25°C to +60°C