Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZMN2-A200
Number of Poles 2-Pole
Rated Current 200 A (Frame Size)
Rated Operational Voltage (Ue) Up to 480V AC
Rated Insulation Voltage (Ui) 690V AC
Rated Ultimate Breaking Capacity (Icu) Typically 25 kA / 35 kA at 480V AC (Confirm with specific datasheet)
Trip Unit Type Type A - Adjustable Electronic Trip Unit
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
Standards Compliance IEC 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, EMT6 Series
Model Number EMT6-K
Power Supply Voltage 24-240V AC/DC (Wide range, auto-sensing)
Output Relay DPDT (2 CO) - 2 Changeover contacts
Contact Rating: Typically 8A @ 250V AC
Timing Ranges Multiple ranges selectable (e.g., from 0.05 seconds up to 100 hours)
Functions Specific set of timing functions selectable (e.g., On-delay, Off-delay, Interval, Flasher, etc. - defined by the "K" variant)
Accuracy ±0.5% of set time ± 20 ms (typical for digital timers)
Mounting DIN Rail (35mm)
Display / Indication LED Status Indicators (Power, Output state)
Standards Compliance IEC/EN 61812-1, UL 508, CSA C22.2 No. 14
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, M22 Series
Model Number M22-R10K
Sensor Type Inductive Proximity Sensor
Housing Material Typically Nickel-plated brass or Stainless Steel
Thread Size M22 x 1.5
Connection Type Pre-wired cable (Specific length varies)
Integrated Resistor 10 kΩ
Sensing Distance 5 mm (Standard for M22 inductive sensors)
Output Type Analog or Special Configuration
Supply Voltage 10-30V DC
Current Consumption Typically ≤ 15 mA
Switching Frequency Typically ≤ 500 Hz
Hysteresis Typically ≤ 10% of sensing distance
Protection Degree IP67
Ambient Temperature -25°C to +70°C
Standards Compliance IEC 60947-5-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, P3 Series
Model Number P3-63-63/EA/SVB
Rated Current (In) 63 A
Number of Poles 3-Pole
Tripping Characteristic Type C (Instantaneous trip: 5-10 x In)
Rated Operational Voltage (Ue) 400/415V AC (Three-Phase)
Rated Insulation Voltage (Ui) 500V AC
Breaking Capacity (Icn) Typically 10 kA / 15 kA (Please confirm with specific catalog)
Auxiliary Function EA - Alarm Switch (Signals trip condition via a separate contact)
Terminal Type SVB - Shrouded Terminal Barrier (Finger Protection)
Mounting Standard 35mm DIN Rail (EN 60715)
Standards Compliance IEC/EN 60898-1
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, SVB Series
Model Number SVB-SW-T0
Accessory Type Shrouded Terminal Barrier
Function Finger Protection / Touch Protection
Compatibility Designed for specific Eaton switch disconnectors (exact compatible models to be verified)
Protection Degree Provides IP20 protection when properly installed
Material Thermoplastic (Typically UL94 V-0 rated for flame retardancy)
Color Typically Orange or safety color for high visibility
Mounting Snap-on installation to compatible Eaton devices
Standards Compliance IEC/EN 60529 (IP Code), relevant parts of IEC/EN 60947 series
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, T0 Series
Model Number T0-4-15682/I1/SVB-SW
Rated Operational Current (Ie) 63 A (at AC-22/AC-23)
Number of Poles 4-Pole (3 phases + neutral)
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 750V AC
Rated Impulse Withstand Voltage (Uimp) 8 kV
Utilization Categories AC-22 (Switching mixed resistive and inductive loads)
AC-23 (Switching motor loads)
Auxiliary Contacts I1 - Specific auxiliary contact configuration (e.g., 1 NO + 1 NC)
Terminal Type SVB-SW - Shrouded Terminal Barrier for switch disconnectors
Operation Type Rotary Handle Operation
Mechanical Life ~ 20,000 operations
Electrical Life ~ 5,000 operations (at rated current)
Mounting DIN Rail (35mm)
Standards Compliance IEC/EN 60947-3
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, T5B Series
Model Number T5B-3-8401
Rated Operational Current (Ie) 125 A (at AC-23)
Number of Poles 3-Pole
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 750V AC
Rated Impulse Withstand Voltage (Uimp) 8 kV
Utilization Categories AC-22 (Switching mixed resistive and inductive loads)
AC-23 (Switching motor loads)
Breaking Capacity Typically 30 kA (at 400V AC)
Operation Type Rotary Handle Operation
Mechanical Life ~ 10,000 operations
Electrical Life ~ 1,500 operations (at rated current)
Mounting Panel Mount
Standards Compliance IEC/EN 60947-3
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, P1 Series (Domae)
Model Number P1-32/I2/SVB
Rated Current (In) 32 A
Number of Poles 1-Pole
Rated Operational Voltage (Ue) 230V AC (Single-Phase)
Rated Insulation Voltage (Ui) 400V AC
Breaking Capacity (Icn) Typically 6 kA / 10 kA (Please confirm with specific catalog)
Tripping Characteristic Type C (Instantaneous trip: 5-10 x In)
Auxiliary Contact I2 - Auxiliary Contact Configuration (e.g., 1 NO or 1 NC contact for remote signaling)
Terminal Type SVB - Shrouded Terminal Barrier (Finger Protection)
Mounting Standard 35mm DIN Rail (EN 60715)
Standards Compliance IEC/EN 60898-1
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, P1 Series (Domae)
Model Number P1-32/2/SVB
Rated Current (In) 32 A
Number of Poles 2-Pole (1P + N)
Rated Operational Voltage (Ue) 230V AC (Single-Phase + Neutral)
Rated Insulation Voltage (Ui) 400V AC
Breaking Capacity (Icn) Typically 6 kA / 10 kA (Please confirm with specific catalog)
Tripping Characteristic Type C (Instantaneous trip: 5-10 x In)
Terminal Type SVB - Shrouded Terminal Barrier (Finger Protection)
Mounting Standard 35mm DIN Rail (EN 60715)
Standards Compliance IEC/EN 60898-1
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, T0 Series
Model Number T0-4-8223/E
Rated Operational Current (Ie) 32 A (at AC-22/AC-23, typical for this code)
Number of Poles 4-Pole (3 phases + neutral)
Rated Operational Voltage (Ue) 690V AC
Rated Insulation Voltage (Ui) 750V AC
Rated Impulse Withstand Voltage (Uimp) 8 kV
Utilization Categories AC-22 (Switching mixed resistive and inductive loads)
AC-23 (Switching motor loads)
Auxiliary Contacts E - Specific auxiliary contact configuration (e.g., 1 NO contact)
Operation Type Rotary Handle Operation
Mechanical Life ~ 20,000 operations
Electrical Life ~ 5,000 operations (at rated current)
Mounting DIN Rail (35mm)
Standards Compliance IEC/EN 60947-3