Technical Parameters
Category Parameter Specification / Description
General Model L2
Type Ball Float Level Controller
Mechanical Float Material Copper (Standard for water), Stainless Steel, or other materials for corrosive liquids.
Lever Arm Length Standard lengths available to suit various tank depths.
Mounting Typically mounts on the side or top of a tank.
Performance Level Control Range Adjustable within the limits of the lever arm length.
Differential The difference between pump start and stop levels is adjustable.
Electrical (if applicable) Switch Rating For electric models: Common ratings are 1/2 HP to 3 HP at 120/240/480 VAC.
Enclosure Weatherproof (NEMA 4) or Explosion-Proof (NEMA 7) enclosures available.
Pneumatic (if applicable) Supply Pressure Typically 20-100 psig (1.4-6.9 bar).
Pilot Valve Output On/Off air signal to operate a pneumatic pump motor starter or other device.
Environment Liquid Specific Gravity Typically designed for S.G. > 0.7.
Temperature Limits Standard materials suitable for most water and wastewater temperatures.
Technical Parameters
Category Parameter Specification / Description
General Model 667-30i
Type Pilot-Operated, Indicating Actuator Pressure Regulator
Input & Output Input Signal 3 to 15 psi (0.2 to 1.0 bar)
Supply Pressure Up to 150 psig (10.3 bar)
Output Pressure 0 to Supply Pressure
Performance Accuracy ±1% of span (including linearity, hysteresis, and repeatability)
Air Consumption Steady State: ~0.15 SCFM (4.2 NLPM)
During Stroking: ~2.0 SCFM (56.6 NLPM)
Capacity (Cv) Approximately 0.7, providing high flow for fast actuator response.
Environmental Ambient Temperature -40°F to 180°F (-40°C to 82°C)
Enclosure Rating Type 3, 3R, 4, 4X, 12 (NEMA); Weatherproof and corrosion-resistant.
Material Aluminum with corrosion-resistant coating.
Physical Pressure Gauge Included (1.5" dial, 0-150 psi range) - this is the "indicating" feature.
Pipe Connections 1/4" NPT for Supply, Input, and Output ports.
Weight Approximately 5 lbs (2.3 kg)
Technical Parameters
Category Parameter Specification / Description
General Part Number 24490-1
Description Trim Kit (Cage, Plug, Seat Ring)
Components Included Parts Cage, Control Plug, Seat Ring.
Typical Specifications Valve Size This specific kit is commonly used for 1.5 inch (NPS 1-1/2") ET valves. This must be verified.
Pressure Class Likely for ANSI Class 150 or 300 valve bodies.
Flow Characteristic Defined by the cage port design (e.g., Equal Percentage, Linear, Quick Opening). The exact characteristic is part of the -1 suffix designation.
Trim Level Likely Standard Trim. This kit may also represent a specific "soft" seat version for tight shut-off.
Materials Cage & Plug Material Typically Stainless Steel (e.g., 316 SS).
Seat Material Could be metal (Stainless Steel) or a soft seat (e.g., PTFE) for enhanced shut-off (Class VI).
Technical Parameters
Category Parameter Specification / Description
General Part Number 24000-333
Description Vee-Ball Segment
Design V-Port Angle 60 Degrees (Included Angle)
Port Type Standard Port
Function Provides a near equal percentage flow characteristic for precise control.
Typical Application Valve Sizes This specific part is commonly used in 3-inch (NPS 3) Vee-Ball valves.
Service General throttling control for liquids, gases, and slurries. Good shearing action for fibrous materials.
Technical Parameters
Category Parameter Specification / Description
General Model 627-348
Type Pilot-Operated Backpressure/Relief Regulator
Pressure & Capacity Body Pressure Rating (ANSI) Typically ANSI Class 300, 600, or higher.
Max. Inlet Pressure (P1) Up to 1440 psig (99 bar) or higher, depending on body class.
Setpoint Pressure Range Defined by the pilot spring. The "-348" code specifies a particular range, which could be in the hundreds of psig.
Flow Capacity (Cv) Very High. Specific Cv depends on main valve size (e.g., 2", 3", 4", 6"). Can range from ~100 to over 1000.
Construction & Materials Body Materials Carbon Steel (Standard), Stainless Steel, Other Alloys.
Trim Materials Stainless Steel.
Pilot Valve 627 Pilot (Relief Pilot) - senses upstream pressure.
Connections & Environment Inlet/Outlet Connections Flanged (RF, RTJ) per ANSI standards.
Vent Connection Flanged or threaded.
Ambient Temperature Standard: -20°F to 150°F (-29°C to 66°C).
Technical Parameters
Category Parameter Specification / Description
General Model 627-328
Type Pilot-Operated Backpressure/Relief Regulator
Pressure & Capacity Body Pressure Rating (ANSI) Typically ANSI Class 300, 600, or higher.
Max. Inlet Pressure (P1) Up to 1440 psig (99 bar) or higher, depending on body class.
Setpoint Pressure Range Defined by the "-328" suffix. This code specifies a particular pilot spring that corresponds to a specific, narrow pressure range (e.g., 30-120 psig, 200-400 psig, etc.). *This is the primary difference from the 627-348.*
Flow Capacity (Cv) Very High. Specific Cv depends on the main valve size defined by "-328".
Construction & Materials Body Materials Carbon Steel (Standard), Stainless Steel, Other Alloys.
Trim Materials Stainless Steel.
Pilot Valve 627 Pilot (Relief Pilot) - senses upstream pressure.
Connections & Environment Inlet/Outlet Connections Flanged (RF, RTJ) per ANSI standards.
Vent Connection Flanged or threaded.
Ambient Temperature Standard: -20°F to 150°F (-29°C to 66°C).
Technical Parameters
Category Parameter Specification / Description
General Model 98L-48.MR95HT
Actuator Type Double-Acting Piston
Positioner MR95HT Multi-Spring, High-Thrust Positioner
Actuator Performance Piston Diameter The "48" likely indicates a 48 square inch effective piston area.
Stroke Length Long stroke, specific length defined by the "L" in 98L (e.g., 8 inches or more).
Thrust Output Extremely High. With a 48 in² piston at 100 psig air supply, theoretical thrust is 4,800 lbs. Actual thrust depends on friction and positioner capability.
Air Supply Pressure Typically up to 100-150 psig (6.9-10.3 bar) for the actuator.
Positioner (MR95HT) Input Signal 3 to 15 psi (0.2 to 1.0 bar) pneumatic
Supply Pressure Up to 150 psig (10.3 bar)
Output Capacity Very High. Designed to provide large volumes of air to quickly fill and exhaust the large piston chamber.
Characterization Linear, Equal Percentage, Quick Open (via characterized cams).
Environmental & Physical Ambient Temperature Standard: -20°F to 150°F (-29°C to 66°C)
Enclosure Rating Weatherproof and/or Explosion-Proof (depending on ordered configuration).
Materials Cast iron or ductile iron construction.
Technical Parameters
Category Parameter Specification / Description
General Model DVC6015
Type Digital Valve Controller (Single-Action)
Product Family FIELDVUE
Primary Protocol HART
Input & Output Input Signal 4 to 20 mA DC, two-wire
Supply Pressure Up to 150 psig (10.3 bar)
Output Action Single-Action (One output port for spring-return actuators)
Performance Linearity ±0.5% of span
Hysteresis Less than 0.4% of span
Air Consumption Steady State: ~0.04 SCFM (1.1 NLPM)
Environmental Ambient Temperature -40°F to 185°F (-40°C to 85°C)
Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water.
Hazardous Area Certifications FM/CSA: Explosion-proof, Intrinsically Safe (Class I, II, III, Div. 1 & 2)
ATEX/IECEx: Ex db, Ex tb, Ex ia [ia] (Zone 1 & 21)
Physical Conduit Openings Two 1/2" NPT
Pneumatic Connections Supply & Output: 1/4" NPT
Technical Parameters
Category Parameter Specification / Description
General Model DVC6200PD
Type Digital Valve Controller (Point-to-Point Digital)
Product Family FIELDVUE
Primary Protocol Foundation Fieldbus H1 or PROFIBUS PA (specified when ordered)
Input & Power Signal & Power Digital signal and device power are provided on the same two-wire loop.
Supply Voltage Typically 9-32 V DC (for Foundation Fieldbus)
Communication Speed 31.25 kbit/s (Foundation Fieldbus H1)
Performance Linearity ±0.5% of span
Hysteresis Less than 0.3% of span
Air Consumption Steady State: ~0.04 SCFM (1.1 NLPM)
Output Capacity Standard and High-Capacity (HC) output modules available.
Environmental Ambient Temperature -40°F to 185°F (-40°C to 85°C)
Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water.
Hazardous Area Certifications FM/CSA & ATEX/IECEx: Intrinsically Safe, Flameproof, and Non-incendive approvals for use in hazardous areas.
Physical Conduit Openings Two 1/2" NPT
Pneumatic Connections Supply & Output: 1/4" NPT
Technical Parameters
Category Parameter Specification / Description
General Model DVC6200HC
Type Digital Valve Controller (High Capacity)
Product Family FIELDVUE
Primary Protocol HART
Input & Output Input Signal 4 to 20 mA DC, two-wire
Supply Pressure Up to 150 psig (10.3 bar)
Performance (HC Output) Output Capacity Supply/Exhaust Flow: Up to 160 SCFM (4531 NLPM). This is the key specification, significantly higher than standard models (~40 SCFM).
Steady-State Air Consumption ~0.04 SCFM (1.1 NLPM)
Linearity ±0.5% of span
Hysteresis Less than 0.3% of span
Environmental Ambient Temperature -40°F to 185°F (-40°C to 85°C)
Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water.
Hazardous Area Certifications FM/CSA & ATEX/IECEx: Explosion-proof, Intrinsically Safe approvals for hazardous areas.
Physical Conduit Openings Two 1/2" NPT
Pneumatic Connections Supply & Output: Typically 1/2" NPT or 3/4" NPT to accommodate the high flow.