FISHER L2
Technical Parameters Category Parameter Specification / Description General Model L2 Type Ball Float Level Controller Mechanical Float Material Copper (Standard for water), Stainless Steel, or other materials for corrosive liquids. Lever Arm Length Standard lengths available to suit various tank depths. Mounting Typically mounts on the side or top of a tank. Performance Level Control Range Adjustable within the limits of the lever arm length. Differential The difference between pump start and stop levels is adjustable. Electrical (if applicable) Switch Rating For electric models: Common ratings are 1/2 HP to 3 HP at 120/240/480 VAC. Enclosure Weatherproof (NEMA 4) or Explosion-Proof (NEMA 7) enclosures available. Pneumatic (if applicable) Supply Pressure Typically 20-100 psig (1.4-6.9 bar). Pilot Valve Output On/Off air signal to operate a pneumatic pump motor starter or other device. Environment Liquid Specific Gravity Typically designed for S.G. > 0.7. Temperature Limits Standard materials suitable for most water and wastewater temperatures.

More details >> Request a Quote >>
___FISHER
FISHER 667-30I
Technical Parameters Category Parameter Specification / Description General Model 667-30i Type Pilot-Operated, Indicating Actuator Pressure Regulator Input & Output Input Signal 3 to 15 psi (0.2 to 1.0 bar) Supply Pressure Up to 150 psig (10.3 bar) Output Pressure 0 to Supply Pressure Performance Accuracy ±1% of span (including linearity, hysteresis, and repeatability) Air Consumption Steady State: ~0.15 SCFM (4.2 NLPM) During Stroking: ~2.0 SCFM (56.6 NLPM) Capacity (Cv) Approximately 0.7, providing high flow for fast actuator response. Environmental Ambient Temperature -40°F to 180°F (-40°C to 82°C) Enclosure Rating Type 3, 3R, 4, 4X, 12 (NEMA); Weatherproof and corrosion-resistant. Material Aluminum with corrosion-resistant coating. Physical Pressure Gauge Included (1.5" dial, 0-150 psi range) - this is the "indicating" feature. Pipe Connections 1/4" NPT for Supply, Input, and Output ports. Weight Approximately 5 lbs (2.3 kg)

More details >> Request a Quote >>
___FISHER
24490-1
Technical Parameters Category Parameter Specification / Description General Part Number 24490-1 Description Trim Kit (Cage, Plug, Seat Ring) Components Included Parts Cage, Control Plug, Seat Ring. Typical Specifications Valve Size This specific kit is commonly used for 1.5 inch (NPS 1-1/2") ET valves. This must be verified. Pressure Class Likely for ANSI Class 150 or 300 valve bodies. Flow Characteristic Defined by the cage port design (e.g., Equal Percentage, Linear, Quick Opening). The exact characteristic is part of the -1 suffix designation. Trim Level Likely Standard Trim. This kit may also represent a specific "soft" seat version for tight shut-off. Materials Cage & Plug Material Typically Stainless Steel (e.g., 316 SS). Seat Material Could be metal (Stainless Steel) or a soft seat (e.g., PTFE) for enhanced shut-off (Class VI).

More details >> Request a Quote >>
___FISHER
24000-333
Technical Parameters Category Parameter Specification / Description General Part Number 24000-333 Description Vee-Ball Segment Design V-Port Angle 60 Degrees (Included Angle) Port Type Standard Port Function Provides a near equal percentage flow characteristic for precise control. Typical Application Valve Sizes This specific part is commonly used in 3-inch (NPS 3) Vee-Ball valves. Service General throttling control for liquids, gases, and slurries. Good shearing action for fibrous materials.

More details >> Request a Quote >>
___FISHER
FISHER 627-348
Technical Parameters Category Parameter Specification / Description General Model 627-348 Type Pilot-Operated Backpressure/Relief Regulator Pressure & Capacity Body Pressure Rating (ANSI) Typically ANSI Class 300, 600, or higher. Max. Inlet Pressure (P1) Up to 1440 psig (99 bar) or higher, depending on body class. Setpoint Pressure Range Defined by the pilot spring. The "-348" code specifies a particular range, which could be in the hundreds of psig. Flow Capacity (Cv) Very High. Specific Cv depends on main valve size (e.g., 2", 3", 4", 6"). Can range from ~100 to over 1000. Construction & Materials Body Materials Carbon Steel (Standard), Stainless Steel, Other Alloys. Trim Materials Stainless Steel. Pilot Valve 627 Pilot (Relief Pilot) - senses upstream pressure. Connections & Environment Inlet/Outlet Connections Flanged (RF, RTJ) per ANSI standards. Vent Connection Flanged or threaded. Ambient Temperature Standard: -20°F to 150°F (-29°C to 66°C).

More details >> Request a Quote >>
___FISHER
FISHER 627-328
Technical Parameters Category Parameter Specification / Description General Model 627-328 Type Pilot-Operated Backpressure/Relief Regulator Pressure & Capacity Body Pressure Rating (ANSI) Typically ANSI Class 300, 600, or higher. Max. Inlet Pressure (P1) Up to 1440 psig (99 bar) or higher, depending on body class. Setpoint Pressure Range Defined by the "-328" suffix. This code specifies a particular pilot spring that corresponds to a specific, narrow pressure range (e.g., 30-120 psig, 200-400 psig, etc.). *This is the primary difference from the 627-348.* Flow Capacity (Cv) Very High. Specific Cv depends on the main valve size defined by "-328". Construction & Materials Body Materials Carbon Steel (Standard), Stainless Steel, Other Alloys. Trim Materials Stainless Steel. Pilot Valve 627 Pilot (Relief Pilot) - senses upstream pressure. Connections & Environment Inlet/Outlet Connections Flanged (RF, RTJ) per ANSI standards. Vent Connection Flanged or threaded. Ambient Temperature Standard: -20°F to 150°F (-29°C to 66°C).

More details >> Request a Quote >>
___FISHER
FISHER 98L-48.MR95HT
Technical Parameters Category Parameter Specification / Description General Model 98L-48.MR95HT Actuator Type Double-Acting Piston Positioner MR95HT Multi-Spring, High-Thrust Positioner Actuator Performance Piston Diameter The "48" likely indicates a 48 square inch effective piston area. Stroke Length Long stroke, specific length defined by the "L" in 98L (e.g., 8 inches or more). Thrust Output Extremely High. With a 48 in² piston at 100 psig air supply, theoretical thrust is 4,800 lbs. Actual thrust depends on friction and positioner capability. Air Supply Pressure Typically up to 100-150 psig (6.9-10.3 bar) for the actuator. Positioner (MR95HT) Input Signal 3 to 15 psi (0.2 to 1.0 bar) pneumatic Supply Pressure Up to 150 psig (10.3 bar) Output Capacity Very High. Designed to provide large volumes of air to quickly fill and exhaust the large piston chamber. Characterization Linear, Equal Percentage, Quick Open (via characterized cams). Environmental & Physical Ambient Temperature Standard: -20°F to 150°F (-29°C to 66°C) Enclosure Rating Weatherproof and/or Explosion-Proof (depending on ordered configuration). Materials Cast iron or ductile iron construction.

More details >> Request a Quote >>
___FISHER
FISHER DVC6015
Technical Parameters Category Parameter Specification / Description General Model DVC6015 Type Digital Valve Controller (Single-Action) Product Family FIELDVUE Primary Protocol HART Input & Output Input Signal 4 to 20 mA DC, two-wire Supply Pressure Up to 150 psig (10.3 bar) Output Action Single-Action (One output port for spring-return actuators) Performance Linearity ±0.5% of span Hysteresis Less than 0.4% of span Air Consumption Steady State: ~0.04 SCFM (1.1 NLPM) Environmental Ambient Temperature -40°F to 185°F (-40°C to 85°C) Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water. Hazardous Area Certifications FM/CSA: Explosion-proof, Intrinsically Safe (Class I, II, III, Div. 1 & 2) ATEX/IECEx: Ex db, Ex tb, Ex ia [ia] (Zone 1 & 21) Physical Conduit Openings Two 1/2" NPT Pneumatic Connections Supply & Output: 1/4" NPT

More details >> Request a Quote >>
___FISHER
FISHER DVC6200PD
Technical Parameters Category Parameter Specification / Description General Model DVC6200PD Type Digital Valve Controller (Point-to-Point Digital) Product Family FIELDVUE Primary Protocol Foundation Fieldbus H1 or PROFIBUS PA (specified when ordered) Input & Power Signal & Power Digital signal and device power are provided on the same two-wire loop. Supply Voltage Typically 9-32 V DC (for Foundation Fieldbus) Communication Speed 31.25 kbit/s (Foundation Fieldbus H1) Performance Linearity ±0.5% of span Hysteresis Less than 0.3% of span Air Consumption Steady State: ~0.04 SCFM (1.1 NLPM) Output Capacity Standard and High-Capacity (HC) output modules available. Environmental Ambient Temperature -40°F to 185°F (-40°C to 85°C) Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water. Hazardous Area Certifications FM/CSA & ATEX/IECEx: Intrinsically Safe, Flameproof, and Non-incendive approvals for use in hazardous areas. Physical Conduit Openings Two 1/2" NPT Pneumatic Connections Supply & Output: 1/4" NPT

More details >> Request a Quote >>
___FISHER
FISHER DVC6200HC
Technical Parameters Category Parameter Specification / Description General Model DVC6200HC Type Digital Valve Controller (High Capacity) Product Family FIELDVUE Primary Protocol HART Input & Output Input Signal 4 to 20 mA DC, two-wire Supply Pressure Up to 150 psig (10.3 bar) Performance (HC Output) Output Capacity Supply/Exhaust Flow: Up to 160 SCFM (4531 NLPM). This is the key specification, significantly higher than standard models (~40 SCFM). Steady-State Air Consumption ~0.04 SCFM (1.1 NLPM) Linearity ±0.5% of span Hysteresis Less than 0.3% of span Environmental Ambient Temperature -40°F to 185°F (-40°C to 85°C) Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water. Hazardous Area Certifications FM/CSA & ATEX/IECEx: Explosion-proof, Intrinsically Safe approvals for hazardous areas. Physical Conduit Openings Two 1/2" NPT Pneumatic Connections Supply & Output: Typically 1/2" NPT or 3/4" NPT to accommodate the high flow.