Products
Products
home
___FISHER
W30382X0032
Typical Specifications Parameter Specification Model DVC6200fp (Assembly: W30382X0032) Communication Protocol Foundation Fieldbus H1 (31.25 kbit/s) with Fisher Proprietary (fp) interface Supply Air Pressure Dependent on the actuator; typically 20 to 150 psi (1.4 to 10.3 bar) Air Consumption Very low quiescent flow; consumption depends on output and stroking Enclosure Rating NEMA 4X (IP66/67) Ambient Temperature -40° to 185°F (-40° to 85°C) Travel Range Dependent on the specific actuator in the assembly. This is a critical parameter that must be confirmed by the detailed product specification sheet. Input Signal Foundation Fieldbus digital signal (via the network) Mounting Directly on linear or rotary actuators (Pre-assembled unit)

More details >> Request a Quote >>
___FISHER
W40159X0012
Typical Specifications Parameter Specification Model DVC2000 (Assembly: W40159X0012) Signal 4-20 mA analog with HART® 5/7 protocol Supply Air Pressure 20 to 150 psi (1.4 to 10.3 bar) - Dependent on actuator capability Air Consumption Low quiescent flow; < 0.2 SCFM (5.7 NLPM) Enclosure Rating NEMA 4X (IP66) Ambient Temperature -40° to 185°F (-40° to 85°C) Travel Range Dependent on the specific actuator in the assembly. Must be confirmed by datasheet. Input Signal 4-20 mA DC, with HART communication Mounting Directly on linear or rotary actuators (Pre-assembled unit)

More details >> Request a Quote >>
___FISHER
TYPE107
Typical Specifications Parameter/Condition Specification Model Type 107 (Size 1 and Size 2 are the most common) Orifice Size Size 1: 1/4 inch (6.4 mm) Size 2: 3/8 inch (9.5 mm) Inlet Supply Pressure Up to 250 psig (17.2 bar) Outlet Pressure Range 5 to 150 psig (0.3 to 10.3 bar) [Adjustable by spring] Maximum Flow Coefficient (Cv) Size 1: ~ 1.0 Size 2: ~ 2.5 Body Material Aluminum (Standard), Ductile Iron (Optional) Connection Sizes 1/4" NPT (Size 1) / 3/8" NPT (Size 2) and 1/2" NPT (for some versions) Temperature Limits Standard Buna-N Elastomer: -20° to 200°F (-29° to 93°C) Optional Viton Elastomer: -20° to 300°F (-29° to 149°C) Approvals Typically meets API 6D requirements.

More details >> Request a Quote >>
___FISHER
W30381X0022
Typical Specifications Parameter Specification Model DVC6200fp (Assembly: W30381X0022) Communication Protocol Foundation Fieldbus H1 (31.25 kbit/s) with Fisher Proprietary (fp) interface Supply Air Pressure Dependent on the actuator; typically 20 to 150 psi (1.4 to 10.3 bar) Air Consumption Very low quiescent flow; consumption depends on output and stroking Enclosure Rating NEMA 4X (IP66/67) Ambient Temperature -40° to 185°F (-40° to 85°C) Travel Range Dependent on the specific actuator in the assembly. This must be confirmed by the detailed datasheet. Input Signal Foundation Fieldbus digital signal (via the network) Mounting Directly on linear or rotary actuators (Pre-assembled unit)

More details >> Request a Quote >>
___FISHER
W30398X0012
Typical Specifications Parameter Specification Model DVC6200 (Assembly: W30398X0012) Signal 4-20 mA analog with HART® protocol (Standard) Supply Air Pressure Typically 20 to 150 psi (1.4 to 10.3 bar) Air Consumption Low quiescent consumption; depends on output volume and stroking speed Enclosure Rating NEMA 4X (IP66/67 equivalent) Ambient Temperature -40° to 185°F (-40° to 85°C) Travel Range Varies with actuator; typically up to 100 mm (linear) or 90° (rotary) Mounting Directly on linear or rotary actuators (Part of a pre-assembled unit in this model) Communication HART® 5/7/ FDT/ DTM (via AMS Device Manager or other compatible systems)

More details >> Request a Quote >>
___FISHER
HSR-CDHBLYN
Technical Parameters Category Parameter Specification / Description Actuator Model/Series HSR Type Double-Acting Rack-and-Pinion Air Connection Likely 1/2" NPT or 3/4" NPT Spring Range Not Applicable (Double-acting has no fail-safe spring) Mounting Style According to ISO 5211 or specific Fisher design for gate valves Valve Valve Type Slab-Disk (Through-Conduit) Gate Valve Valve Size Varies (e.g., 2", 3", 4", 6" - specified when ordering) Pressure Class Varies (e.g., ANSI 600, 900, 1500, 2500) End Connection Flanged (RF or RTJ) or Buttweld (specified when ordering) Positioner & Control Positioner Model FIELDVUE DVC6200 Series or similar Communication Protocol FOUNDATION Fieldbus H1 Supply Pressure Typical: 20 - 100 psi (1.4 - 6.9 bar) Diagnostics Full suite of digital diagnostics (travel, pressure, etc.) Performance & Environment Operating Temperature Standard: -20°F to +180°F (-29°C to +82°C) Extended ranges available Explosive Atmosphere Certification Explosion-Proof (e.g., ATEX, IECEx, or cFMus for Class I, Division 1, Groups B, C, D) Enclosure Rating Typically IP66 / IP67 (Dust-tight and protected against water jets/immersion) Materials Aluminum actuator body, epoxy coating. Stainless steel internals. Valve trim materials per application.

More details >> Request a Quote >>
___FISHER
DVC6215
Technical Parameters Category Parameter Specification / Description General Model DVC6215 Description Digital Valve Controller (HART Protocol) Product Family FIELDVUE Input & Control Input Signal 4 to 20 mA DC, two-wire (sourcing) Supply Pressure Minimum: 2.5 psig (0.17 bar) above actuator requirement Maximum: See table below for supply pressure vs. enclosure material. Characterization Linear, Quick-Open, Equal Percentage, and custom user-configurable Performance Sensitivity 0.05% of span Linearity ±0.5% of span (default) Hysteresis Less than 0.2% of span Air Consumption Steady State: ~0.04 SCFM (1.1 NLPM) During Stroking: ~1.5 SCFM (42.5 NLPM) Pneumatic Output Output Capacity Supply Relay: Up to 100 SCFM (2832 NLPM) Exhaust Relay: Up to 40 SCFM (1133 NLPM) Environmental Ambient Temperature Standard: -40°F to 185°F (-40°C to 85°C) Extended: -40°F to 185°F (-40°C to 85°C) with specific seals. Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water jets/immersion. Material & Pressure Aluminum: Max 150 psig (10.3 bar) Stainless Steel: Max 365 psig (25.2 bar) Hazardous Area Certifications FM/CSA: Explosion-proof, Dust-ignition proof, Intrinsically Safe (Class I, II, III, Div. 1 & 2) ATEX/IECEx: Ex db, Ex tb, Ex ia [ia] (Zone 1 & 21) Physical Conduit Openings Two 1/2" NPT conduit openings Pneumatic Connections Supply & Output: 1/4" NPT Gauges: 1/8" NPT Weight Aluminum: Approx. 4.5 kg (10 lbs) Stainless Steel: Approx. 9.1 kg (20 lbs)

More details >> Request a Quote >>
___FISHER
FISHER F8-67CFR
Technical Parameters Category Parameter Specification / Description General Model F8-67CFR Type Pilot-Operated, Pressure-Reducing Regulator with Digital Controller Product Line FIELDVUE Input & Control Input Signal 4 to 20 mA DC, two-wire (Standard HART protocol) Supply Pressure (Max) For F8 Body: 400 psig (27.6 bar) Setpoint Range 3 to 115 psig (0.2 to 7.9 bar) - Adjustable within supply pressure limits Performance Output Pressure Range 0 to 100 psig (0 to 6.9 bar) Supply Pressure Effect ±0.2 psig (±0.014 bar) for a 50 psig (3.4 bar) supply change Flow Capacity (Cv) Inlet: 0.7 Outlet: 0.4 Accuracy ±0.5% of span (typical) Stability (Drift) Less than ±0.25% of span per month Environmental Ambient Temperature Standard Electronics: -20°F to 175°F (-29°C to 80°C) Enclosure Rating Type 4X, 6 (IP66/67); Dust-tight and protected against water. Material Body: Aluminum Trim: Stainless Steel Hazardous Area Certifications FM/CSA: Explosion-proof & Intrinsically Safe (Class I, Div. 1, Groups A, B, C, D) ATEX/IECEx: Ex db, Ex ia [ia] (Zone 1) Physical Pipe Connections 1/4" or 1/2" NPT (Internal) - Specific size is part of the model code Weight Approximately 4.1 kg (9 lbs)

More details >> Request a Quote >>
___FISHER
FISHER 167DA-13
Technical Parameters Category Parameter Specification / Description General Model 167DA-13 Type Direct-Acting Spring-Diaphragm Actuator Diaphragm Diameter 167 mm (7 inches) Performance Spring Range The "-13" is a key identifier. Exact pressure range (e.g., 3-15 psi, 0.2-1.0 bar, 6-30 psi) must be confirmed from the Fisher Spring Rate Table. This is the standard air signal pressure needed to stroke the actuator. Strokes Available Multiple standard strokes are available (e.g., 25 mm, 38 mm, 50 mm, etc.). The specific stroke is determined when ordered. Thrust Output Air Pressure (psi) Downward Thrust (lbs) Upward Thrust (Spring, lbs) 20 psi (1.4 bar) ~2,100 lbs ~1,600 lbs 30 psi (2.1 bar) ~2,900 lbs ~1,600 lbs Note: Thrust values are approximate and depend heavily on the specific spring range and stroke. Physical & Environmental Diaphragm Case Material Cast Iron or Ductile Iron with corrosion-resistant coating. Spring Material Music wire with protective coating. Yoke Material Cast Iron or Ductile Iron. Standard Temperature For springs: -20°F to 150°F (-29°C to 66°C). Higher temp springs available. Mounting Designed to mount to Fisher 585C series globe valve bodies and other compatible valves.

More details >> Request a Quote >>
___FISHER
FISHER 377
Technical Parameters。 Category Parameter Specification / Description General Model Series 377 Type Pilot-Operated Pressure Reducing Regulator Valve Style Balanced, Single-Port, Semi-Soft Seated Pressure Ratings Body Rating (ANSI) ANSI Class 150, 300, 400, 600, 900 (depending on body size and material) Max. Inlet Pressure (P1) Up to 1440 psig (100 bar) for certain sizes and classes. Outlet Pressure Range (P2) Adjustable via pilot spring. Wide range, from a few psig to over 1000 psig, depending on the pilot and spring. Flow & Sizing Flow Capacity (Cv) Ranges from approximately 30 to over 1000+ depending on the valve size (e.g., 1", 2", 3", 4", 6", 8"). End Connections Flanged (RF, RTJ) according to ANSI standards. Temperature & Materials Process Fluid Temp. Standard: -20°F to 150°F (-29°C to 66°C). Extended ranges with different seals/materials. Body Materials Carbon Steel (Standard), Ductile Iron, Stainless Steel. Trim Materials Stainless Steel Trim. Semi-Soft Seat (e.g., TFE, Nylon, Kel-F). Pilots & Options Standard Pilot 377 Pilot (Reducing Pilot) - senses downstream pressure. Common Options • Monitor Pilot: For overpressure protection. • SLM (Slow Opening) Pilot: For safe start-up. • Relief Pilots: To act as a backpressure regulator.

More details >> Request a Quote >>
1 2
··· ···