DILM9-01(24VDC)
Parameter Specification Product Series DILM9 Brand Eaton Product Type Contactor Number of Main Poles 3 Poles (3P) Rated Thermal Current (Ith) 1.5 A (at 55°C) Rated Operational Power at AC-3 (400V) 0.75 kW / 1 HP Rated Operational Voltage (Ue) Up to 690 V AC Control Coil Voltage 24 V DC Utilization Categories AC-1: Non-inductive loads AC-3: Squirrel-cage motors (Starting, switching off during running) AC-4: Squirrel-cage motors (Starting, plugging, inching) Mechanical Life 20 - 30 million operations Electrical Life (AC-3) 4 - 6 million operations Electrical Life (AC-4) Up to 1.5 million operations (This high AC-4 life is a key feature of the DILM9 series) Auxiliary Contacts 2 convertible contacts (can be set as NO or NC) as standard. Expandable with additional auxiliary contact blocks. Mounting DIN Rail Mounting (35mm) or Screw Mounting Standards IEC/EN 60947-4-1, UL 508, CSA C22.2

More details >> Request a Quote >>
EATON
DILM9-10(24VDC)
Parameter Specification Product Series DILM9 Brand Eaton Product Type Contactor Number of Main Poles 3 Poles (3P) Rated Thermal Current (Ith) 10 A (at 55°C) Rated Operational Power at AC-3 (400V) 4 kW / 5.5 HP Rated Operational Voltage (Ue) Up to 690 V AC Control Coil Voltage 24 V DC Utilization Categories AC-1: Non-inductive loads AC-3: Squirrel-cage motors (Starting, switching off during running) AC-4: Squirrel-cage motors (Starting, plugging, inching) - with very high electrical life Mechanical Life 20 - 30 million operations Electrical Life (AC-3) 4 - 6 million operations Electrical Life (AC-4) Up to 1.5 million operations (significantly higher than standard contactors) Auxiliary Contacts 2 convertible contacts (can be set as NO or NC) as standard. Expandable with additional auxiliary contact blocks. Mounting DIN Rail Mounting (35mm) or Screw Mounting Standards IEC/EN 60947-4-1, UL 508, CSA C22.2

More details >> Request a Quote >>
EATON
DILM7-01(24VDC)
Parameter Specification Product Series DILM7 Brand Eaton Product Type Contactor Number of Main Poles 3 Poles (3P) Rated Thermal Current (Ith) 1.5 A Rated Operational Power at AC-3 (400V) 0.75 kW / 1 HP Rated Operational Voltage (Ue) Up to 690 V AC Control Coil Voltage 24 V DC Utilization Categories AC-1: Non-inductive or slightly inductive loads AC-3: Squirrel-cage motors (Starting, switching off during running) AC-4: Squirrel-cage motors (Starting, plugging, inching) Mechanical Life 10 - 30 million operations Electrical Life (AC-3) 1.3 - 2 million operations Auxiliary Contacts Typically 1 NO (Normally Open) + 1 NC (Normally Closed) as standard (configurable options may exist) Mounting DIN Rail Mounting (35mm) or Screw Mounting Standards IEC/EN 60947-4-1, UL 508, CSA C22.2

More details >> Request a Quote >>
EATON
DILM7-10(24VDC)
Parameter Specification Product Series DILM7 Brand Eaton Product Type Contactor Number of Main Poles 3 Poles (3P) Rated Thermal Current (Ith) 10 A Rated Operational Power at AC-3 (400V) 4 kW / 5.5 HP Rated Operational Voltage (Ue) Up to 690 V AC Control Coil Voltage 24 V DC Utilization Categories AC-1: Non-inductive or slightly inductive loads AC-3: Squirrel-cage motors (Starting, switching off during running) AC-4: Squirrel-cage motors (Starting, plugging, inching) Mechanical Life 10 - 30 million operations Electrical Life (AC-3) 1.3 - 2 million operations Auxiliary Contacts Typically 1 NO (Normally Open) + 1 NC (Normally Closed) as standard (configurable options may exist) Mounting DIN Rail Mounting (35mm) or Screw Mounting Standards IEC/EN 60947-4-1, UL 508, CSA C22.2

More details >> Request a Quote >>
EATON
FAZ-XHIN11
Parameter Specification Product Series FAZ (Molded Case Circuit Breaker Trip Unit) Brand Eaton Product Type Electronic Trip Unit (ETU) / Trip Relay Rated Supply Voltage Powered by the current transformers within the breaker (Self-powered) Protection Functions Long-Time Delay (LSD) - Overload Short-Time Delay (STD) - Short-circuit Instantaneous (INST) - Severe short-circuit Ground Fault (GND) - Earth leakage protection Adjustability Fully Adjustable: - Long-Time Current (Ir): Adjustable percentage of the breaker's frame rating. - Long-Time Delay (tr): Adjustable. - Short-Time Current (Isd): Adjustable multiple of Ir. - Short-Time Delay (tsd): Adjustable. - Instantaneous Current (Ii): Adjustable multiple of Ir. - Ground-Fault Current (Ig): Adjustable. - Ground-Fault Delay (tg): Adjustable. Display Typically an LCD or LED display for status, current readings, and fault indications. Testing Built-in self-test and functional test capabilities. Communication None. The XHIN11 is a stand-alone trip unit. For communication (e.g., via Modbus, Profibus), a separate communication module (like Eaton's COM module) and a different ETU (e.g., with "C" in the name) would be required. Standards IEC 60947-2

More details >> Request a Quote >>
EATON
NZMB2-M125
Parameter Specification Product Series NZMB2 Brand Eaton Product Type Miniature Circuit Breaker (MCB) Number of Poles 2 Poles (2P) Rated Current (In) 125 A Tripping Characteristic M Curve (Instantaneous trip current: 12 to 15 times In) Rated Operational Voltage (Ue) 230/400 V ~ Rated Insulation Voltage (Ui) 500 V ~ Rated Impulse Withstand Voltage (Uimp) 6 kV Rated Breaking Capacity (Icn) 25 kA (at 400V AC according to IEC 60947-2) Standards IEC 60947-2 Electrical Life 8,000 cycles Mechanical Life 20,000 cycles Terminal Type Stud Terminal (for large cable/bar connections) Mounting DIN Rail Mounting (35mm symmetrical rail according to EN 60715) Net Weight Approx. 1.4 kg (May vary)

More details >> Request a Quote >>
EATON
NZMB2-M160
Parameter Specification Product Series NZMB2 Brand Eaton Product Type Miniature Circuit Breaker (MCB) Number of Poles 2 Poles (2P) Rated Current (In) 160 A Tripping Characteristic M Curve (Instantaneous trip current: 12 to 15 times In) Rated Operational Voltage (Ue) 230/400 V ~ Rated Insulation Voltage (Ui) 500 V ~ Rated Impulse Withstand Voltage (Uimp) 6 kV Rated Breaking Capacity (Icn) 25 kA (at 400V AC according to IEC 60947-2) Standards IEC 60947-2 Electrical Life 8,000 cycles Mechanical Life 20,000 cycles Terminal Type Stud Terminal (for large cable/bar connections) Mounting DIN Rail Mounting (35mm symmetrical rail according to EN 60715) Net Weight Approx. 1.5 kg (May vary)

More details >> Request a Quote >>
EATON
NZMB2-A250
Parameter Specification Product Series NZMB2 Brand Eaton Product Type Miniature Circuit Breaker (MCB) Number of Poles 2 Poles (2P) Rated Current (In) 250 A Tripping Characteristic A Curve (Instantaneous trip current: 2 to 3 times In) Rated Operational Voltage (Ue) 230/400 V ~ Rated Insulation Voltage (Ui) 500 V ~ Rated Impulse Withstand Voltage (Uimp) 6 kV Rated Breaking Capacity (Icn) 25 kA (at 400V AC according to IEC 60947-2) Standards IEC 60947-2 Electrical Life 8,000 cycles Mechanical Life 20,000 cycles Terminal Type Stud Terminal (for large cable/bar connections) Mounting DIN Rail Mounting (35mm symmetrical rail according to EN 60715) Net Weight Approx. 1.8 kg (May vary)

More details >> Request a Quote >>
EATON
U-PKZ0(230V50HZ)
Parameter Specification Product Series PKZ Zero (Moeller) Brand Eaton Product Type Thermal Overload Relay Rated Operational Voltage (Ue) Up to 690 V AC (This rating fully encompasses and exceeds the 230V requirement) Application 3-phase AC Motor Protection Standards IEC/EN 60947-4-1, IEC/EN 60947-5-1 Protection Functions Overload, Phase Unbalance, Phase Loss Trip Class Class 10 (Standard for general-purpose motors) Ambient Temperature Compensation Yes, typically from -20°C to +60°C Reset Mode Manual (Standard) Mounting Snap-on mounting to Eaton XT/XT1 series contactors Auxiliary Contacts Typically 1 NO (97-98) + 1 NC (95-96)

More details >> Request a Quote >>
EATON
U-PKZ0(380V50HZ)
Parameter Specification Product Series PKZ Zero (Moeller) Brand Eaton Product Type Thermal Overload Relay Rated Operational Voltage (Ue) Up to 690 V AC (Fully rated for 380V/400V systems) Application 3-phase AC Motor Protection Standards IEC/EN 60947-4-1, IEC/EN 60947-5-1 Protection Functions Overload, Phase Unbalance, Phase Loss Trip Class Class 10 (Standard, trips within 10 seconds at 7.2 times the set current) Ambient Temperature Compensation Yes, from -20°C to +60°C Reset Mode Manual (Standard) Mounting Snap-on mounting to Eaton XT/XT1 series contactors Auxiliary Contacts Typically 1 NO (97-98) + 1 NC (95-96)

More details >> Request a Quote >>