Parameter Specification
Product Series NZM3
Brand Eaton
Product Type Vacuum Contactor
Number of Main Poles 3 Poles (3P)
Rated Operational Voltage (Ue) Typically 7.2 kV or 12 kV (This is a key parameter that must be confirmed from the nameplate).
Rated Frequency 50/60 Hz
Rated Normal Current (Ie) Varies by model, common ratings are 200A, 400A, 600A (e.g., NZM3-400). Must be confirmed.
Rated Making/Breaking Capacity Defined for specific duties (e.g., AC-3 for motors). High breaking capacity due to vacuum technology.
Control Coil Voltage Likely 110V DC (as suggested by "VR" in the model code). Other voltages like 24V DC or 220V DC are possible. Must be confirmed.
Operating Mechanism Electromagnetic, spring-operated for fast and consistent opening and closing.
Dielectric Strength High, suitable for medium-voltage systems.
Auxiliary Contacts Multiple normally open (NO) and normally closed (NC) contacts for control and signaling interlocking.
Mounting Fixed mounting on a panel or in a switchgear compartment.
Standards IEC 60470, IEC 60694, ANSI/IEEE C37.04
Parameter Specification
Product Series EMT6
Brand Eaton / Moeller
Product Type Motor Protection Circuit Breaker (MPCB)
Number of Poles 3-Pole (3P)
Rated Operational Voltage (Ue) Up to 690V AC
Rated Current (In) The "KDB" code specifies the current rating. This is likely in the range of 0.1A to 25A (e.g., 0.16A, 0.25A, 0.4A, ... 25A). The exact value must be confirmed from the nameplate or datasheet.
Rated Breaking Capacity (Icu/Ics) Typically 50kA / 100kA at 400V AC according to IEC 60947-2.
Trip Class Class 10 (Standard for motor protection, trips within 10 seconds at 7.2 x Ir).
Utilization Category AC-3 (For squirrel-cage motor starting and switching off during running).
Motor Power Rating (at 400V) Varies with the current setting (e.g., from ~0.06kW to ~15 kW).
Adjustment The overload current setting (Ir) is typically adjustable within a range (e.g., 0.1-0.16A, 1-1.6A, etc.).
Auxiliary Contacts Can be fitted with auxiliary contact blocks (e.g., 1 NO + 1 NC) for control and signaling.
Shunt Release / Undervoltage Release Can be fitted with these accessories for remote tripping or loss-of-voltage protection.
Mounting DIN Rail Mounting (35mm)
Standards IEC/EN 60947-1, IEC/EN 60947-2
Parameter Specification
Product Series EMR6
Brand Eaton
Product Type Electronic Motor Protection Relay
Main Circuit Voltage Up to 690V AC
Motor Current Sensing Via external Current Transformers (CTs). The rating depends on the CTs used (e.g., for a 500A motor, 500:5A CTs would be used).
Control Supply Voltage (D) 24-48V DC (Standard for "D" designation) or 100-240V AC/DC (depending on variant). Must be confirmed with datasheet.
Protection Functions - Overload (Thermal replica)
- Short-Circuit (Instantaneous)
- Phase Unbalance / Loss
- Locked Rotor / Jam
- Undercurrent / Load Loss
- Earth Fault (Ground Fault)
- Tachometer Overspeed/Underspeed (if equipped with speed sensing)
Control Functions - Start/Stop Control
- Two-Wire / Three-Wire Control
- Auto-Restart
- Communication Capabilities
Output Relays Typically 2 or 3 changeover relays for Fault, Warning, and General Control.
Communication Common options: Modbus RTU, Profibus DP, or DeviceNet (highly dependent on the exact variant).
Display & Interface LCD or LED display for setpoints, actual values, and fault messages.
Mounting DIN Rail Mounting (35mm)
Standards IEC/EN 60947-4-1, IEC/EN 60947-5-1
Parameter Specification
Product Series DIL M7
Brand Eaton / Moeller
Product Type Contactor
Number of Main Poles 3 Poles (3P)
Rated Thermal Current (Ith) 1.5 A (at 55°C)
Rated Operational Power at AC-3 (400V) 0.75 kW / 1 HP
Rated Operational Voltage (Ue) Up to 690 V AC
Control Coil Voltage 110 V DC
Utilization Categories AC-1: Non-inductive loads
AC-3: Squirrel-cage motors (Starting, switching off during running)
AC-4: Squirrel-cage motors (Starting, plugging, inching)
Mechanical Life 10 - 30 million operations
Electrical Life (AC-3) 1.3 - 2 million operations
Auxiliary Contacts Typically 1 NO (Normally Open) + 1 NC (Normally Closed) as standard (as indicated by the "C" suffix).
Mounting DIN Rail Mounting (35mm) or Screw Mounting
Standards IEC/EN 60947-4-1, VDE 0660, etc.
Parameter Specification
Product Series DIL M12
Brand Eaton / Moeller
Product Type Contactor
Number of Main Poles 3 Poles (3P)
Rated Thermal Current (Ith) ~32 A to ~40 A (Estimated for size "-01". Must be confirmed.)
Rated Operational Power at AC-3 (400V) ~15 kW to ~18.5 kW (Estimate based on a ~32A rating)
Rated Operational Voltage (Ue) Up to 690 V / 1000 V AC
Control Coil Voltage 110 V DC
Utilization Categories AC-1: Non-inductive loads
AC-3: Squirrel-cage motors (Starting, switching off during running)
AC-4: Squirrel-cage motors (Starting, plugging, inching)
Mechanical Life 10 - 20 million operations
Electrical Life (AC-3) 1 - 3 million operations
Auxiliary Contacts Typically includes 1 Normally Open (NO) + 1 Normally Closed (NC) auxiliary contact as standard (as suggested by the "C" suffix). Expandable with additional contact blocks.
Mounting Screw Mounting (Panel mounting)
Standards IEC/EN 60947-4-1, VDE 0660, etc.
Parameter Specification
Product Series DIL M15
Brand Eaton / Moeller
Product Type Contactor
Number of Main Poles 3 Poles (3P)
Rated Thermal Current (Ith) ~80 A to ~100 A (Estimated for size "-01". Must be confirmed.)
Rated Operational Power at AC-3 (400V) ~37 kW to ~55 kW (Estimate based on the current range)
Rated Operational Voltage (Ue) Up to 690 V / 1000 V AC
Control Coil Voltage 24 V DC
Utilization Categories AC-1: Non-inductive loads
AC-3: Squirrel-cage motors (Starting, switching off during running)
AC-4: Squirrel-cage motors (Starting, plugging, inching)
Mechanical Life Several million operations
Electrical Life (AC-3) Several hundred thousand operations
Auxiliary Contacts Typically includes auxiliary contacts (e.g., 1 NO + 1 NC as suggested by "LN"). Expandable with additional contact blocks.
Mounting Screw Mounting (Panel mounting)
Standards IEC/EN 60947-4-1, VDE 0660, etc.
Parameter Specification
Product Series DILM15
Brand Eaton
Product Type Contactor
Number of Main Poles 3 Poles (3P)
Rated Thermal Current (Ith) ~80 A to ~100 A (Estimated for size "-01". Must be confirmed.)
Rated Operational Power at AC-3 (400V) ~37 kW to ~55 kW (Estimate based on the current range)
Rated Operational Voltage (Ue) Up to 1000 V AC
Control Coil Voltage 24 V DC
Utilization Categories AC-1: Non-inductive loads
AC-3: Squirrel-cage motors (Starting, switching off during running)
AC-4: Squirrel-cage motors (Starting, plugging, inching)
Mechanical Life Several million operations
Electrical Life (AC-3) Several hundred thousand operations
Auxiliary Contacts Includes convertible auxiliary contacts (can be set as NO or NC). Expandable with additional contact blocks.
Mounting Screw Mounting (Panel mounting)
Standards IEC/EN 60947-4-1, UL 508, CSA C22.2
Parameter Specification
Product Series DILM15
Brand Eaton
Product Type Contactor
Number of Main Poles 3 Poles (3P)
Rated Thermal Current (Ith) ~110 A to ~125 A (Estimated for size "-10". Must be confirmed.)
Rated Operational Power at AC-3 (400V) ~55 kW to ~63 kW (Estimate based on a ~110A rating)
Rated Operational Voltage (Ue) Up to 1000 V AC
Control Coil Voltage 24 V DC
Utilization Categories AC-1: Non-inductive loads
AC-3: Squirrel-cage motors (Starting, switching off during running)
AC-4: Squirrel-cage motors (Starting, plugging, inching)
Mechanical Life Several million operations
Electrical Life (AC-3) Several hundred thousand operations
Auxiliary Contacts Includes convertible auxiliary contacts (can be set as NO or NC). Expandable with additional contact blocks.
Mounting Screw Mounting (Panel mounting)
Standards IEC/EN 60947-4-1, UL 508, CSA C22.2
Parameter Specification
Product Series DILM12
Brand Eaton
Product Type Contactor
Number of Main Poles 3 Poles (3P)
Rated Thermal Current (Ith) ~32 A to ~40 A (Estimated for size "-01". Must be confirmed.)
Rated Operational Power at AC-3 (400V) ~15 kW to ~18.5 kW (Estimate based on a ~32A rating)
Rated Operational Voltage (Ue) Up to 1000 V AC
Control Coil Voltage 24 V DC
Utilization Categories AC-1: Non-inductive loads
AC-3: Squirrel-cage motors (Starting, switching off during running)
AC-4: Squirrel-cage motors (Starting, plugging, inching)
Mechanical Life 10 - 20 million operations
Electrical Life (AC-3) 1 - 3 million operations
Electrical Life (AC-4) Several hundred thousand operations
Auxiliary Contacts Typically includes convertible auxiliary contacts (can be set as NO or NC). Expandable with additional contact blocks.
Mounting Screw Mounting (Panel mounting)
Standards IEC/EN 60947-4-1, UL 508, CSA C22.2
Parameter Specification
Product Series DILM12
Brand Eaton
Product Type Contactor
Number of Main Poles 3 Poles (3P)
Rated Thermal Current (Ith) ~32 A to ~100 A (This is an estimate. The actual value for the "-10" model must be verified.)
Rated Operational Power at AC-3 (400V) ~15 kW to ~55 kW (Depends on the exact current rating)
Rated Operational Voltage (Ue) Up to 1000 V AC
Control Coil Voltage 24 V DC
Utilization Categories AC-1: Non-inductive loads
AC-3: Squirrel-cage motors (Starting, switching off during running)
AC-4: Squirrel-cage motors (Starting, plugging, inching)
Mechanical Life 10 - 20 million operations
Electrical Life (AC-3) 1 - 3 million operations
Electrical Life (AC-4) Several hundred thousand operations
Auxiliary Contacts Typically includes convertible auxiliary contacts (can be set as NO or NC). Expandable with additional contact blocks.
Mounting Screw Mounting (Designed for panel mounting, may not be for DIN rail)
Standards IEC/EN 60947-4-1, UL 508, CSA C22.2