Products
Products
home
EATON
NZMN1-A20
Technical Parameters Parameter Specification Product Series Eaton NZMN1 Product Type Molded Case Circuit Breaker (MCCB) Rated Operational Current (Ie) 20 A Number of Poles 3 Trip Unit Type Fixed Thermal-Magnetic Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 800 V AC Rated Frequency 50/60 Hz Short-Circuit Breaking Capacity (Icu) Typically 25 kA (at 400V AC per IEC 60947-2) Utilization Category A (for non-specific applications) Mounting Fixed Mounting (DIN Rail or panel) Terminal Type Screw clamp Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
NZMN1-A50
Technical Parameters Parameter Specification Product Series Eaton NZMN1 Product Type Molded Case Circuit Breaker (MCCB) Rated Operational Current (Ie) 50 A Number of Poles 3 Trip Unit Type Fixed Thermal-Magnetic Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 800 V AC Rated Frequency 50/60 Hz Short-Circuit Breaking Capacity (Icu) Typically 25 kA (at 400V AC per IEC 60947-2) Utilization Category A (for non-specific applications) Mounting Fixed Mounting (DIN Rail or panel) Terminal Type Screw clamp Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
NZMN-A80
Technical Parameters Parameter Specification Product Series Eaton NZMN Product Type Molded Case Circuit Breaker (MCCB) Rated Operational Current (Ie) 80 A Trip Unit Type Fixed Thermal-Magnetic Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 800 V AC Rated Frequency 50/60 Hz Short-Circuit Breaking Capacity (Icu) Typically 10-25 kA (depending on specific variant and voltage) Mounting Fixed Mounting (DIN Rail or panel) Terminal Type Screw clamp Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
NZMN1-A100
Technical Parameters Parameter Specification Product Series Eaton NZMN1 Product Type Molded Case Circuit Breaker (MCCB) Rated Operational Current (Ie) 100 A Number of Poles 3 Trip Unit Type Fixed Thermal-Magnetic Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 800 V AC Rated Frequency 50/60 Hz Short-Circuit Breaking Capacity (Icu) Typically 25 kA (at 400V AC per IEC 60947-2) Utilization Category A (for non-specific applications) Mounting Fixed Mounting (DIN Rail or panel) Terminal Type Screw clamp Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
NZM4-XR208-240C
Technical Parameters Parameter Specification Product Series Eaton NZM4 Product Type Electronic Trip Unit with Communication Rated Current (In) 208-240A (as indicated by model suffix) Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Frequency 50/60 Hz Protection Functions L (Long-time), S (Short-time), I (Instantaneous), G (Ground Fault) Communication Protocol Modbus RTU (via RS-485 interface) Measurement Capabilities Current, Voltage, Power, Energy, Power Factor, Frequency Display Integrated LCD display Setting Adjustment Programmable via front interface or communication network Mounting Integrated into compatible NZM4 circuit breaker frame Standards Compliance IEC 60947-2

More details >> Request a Quote >>
EATON
DILM820-XHB
Technical Parameters Parameter Specification Product Series Eaton DILM Product Type AC Power Contactor Rated Operational Current (Ie) 820 A Rated Thermal Current (Ith) 820 A Number of Poles 3 Auxiliary Contacts Typically 2 NO + 2 NC (configurable) Rated Operational Voltage (Ue) Up to 1000 V AC Control Coil Voltage Specific voltage indicated by XHB code variant Motor Load Rating (AC-3) 400 kW at 400V AC Electrical Life (AC-3) Up to 1 million operations Mechanical Life Up to 10 million operations Mounting Panel mounting or base plate mounting Terminal Type Screw clamp or busbar connection Standards Compliance IEC 60947-4-1, UL 508

More details >> Request a Quote >>
EATON
DILM820-XKB-S
Technical Parameters Parameter Specification Product Series Eaton DILM Product Type AC Power Contactor Rated Operational Current (Ie) 820 A Rated Thermal Current (Ith) 820 A Number of Poles 3 Rated Operational Voltage (Ue) Up to 1000 V AC Control Coil Voltage Specific voltage indicated by XKB code variant Motor Load Rating (AC-3) 400 kW at 400V AC Electrical Life (AC-3) Up to 1 million operations Mechanical Life Up to 10 million operations Mounting Panel mounting or base plate mounting Terminal Type Screw clamp or busbar connection Special Features Custom configuration as indicated by "-S" suffix Standards Compliance IEC 60947-4-1, UL 508

More details >> Request a Quote >>
EATON
DILM820-XMV
Technical Parameters Parameter Specification Product Series Eaton DILM Product Type AC Power Contactor Rated Operational Current (Ie) 820 A Rated Thermal Current (Ith) 820 A Number of Poles 3 Auxiliary Contacts Configurable (typically 2 NO + 2 NC) Rated Operational Voltage (Ue) Up to 1000 V AC Control Coil Voltage Various voltages available (specific voltage indicated by XMV code) Motor Load Rating (AC-3) 400 kW at 400V AC Electrical Life (AC-3) Up to 1 million operations Mechanical Life Up to 10 million operations Mounting Panel mounting or base plate mounting Terminal Type Screw clamp or busbar connection Standards Compliance IEC 60947-4-1, UL 508

More details >> Request a Quote >>
EATON
EIS-80/4
Technical Parameters Parameter Specification Product Series Eaton EIS Product Type Load Break Switch / Disconnector Rated Operational Current (Ie) 80 A Number of Poles 4 (3 phases + neutral) Rated Operational Voltage (Ue) 400 V AC Rated Insulation Voltage (Ui) 690 V AC Utilization Category AC-22A / AC-23A Mechanical Life ≥ 20,000 operations Electrical Life ≥ 5,000 operations at rated current Protection Degree IP20 (when properly installed in enclosure) Mounting DIN Rail (35 mm) Terminal Type Screw clamp Connection Capacity Suitable for rigid and flexible conductors Standards Compliance IEC 60947-3

More details >> Request a Quote >>
EATON
EIS-80/3
Technical Parameters Parameter Specification Product Series Eaton EIS Product Type Load Break Switch / Disconnector Rated Operational Current (Ie) 80 A Number of Poles 3 Rated Operational Voltage (Ue) 400 V AC Rated Insulation Voltage (Ui) 690 V AC Utilization Category AC-22A / AC-23A Mechanical Life ≥ 20,000 operations Electrical Life ≥ 5,000 operations at rated current Protection Degree IP20 (when properly installed in enclosure) Mounting DIN Rail (35 mm) Terminal Type Screw clamp Connection Capacity Suitable for rigid and flexible conductors Standards Compliance IEC 60947-3

More details >> Request a Quote >>
1 2
··· ···