Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-C10/3
Fuse Class & Rating Class CC
Rated Current: 10 A
Rated Voltage: 600V AC
Number of Poles / Quantity 3 pieces (Typically supplied as a 3-pole set for a 3-phase application)
Type Fast-Acting (Non-Time-Delay)
Rated Voltage 600V AC / 300V DC
Rated Breaking Capacity (Interrupting Rating) 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4, IEC 60269-1 (Optional)
Electrical Characteristics Current-Limiting: Yes
Melting I²t (10A): Approximately 1.5 A²s (Refer to official datasheet for precise values)
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting / Fuse Holder Requires a compatible Class CC fuse holder or fuse block (e.g., Eaton FHCC100, KRP-C-100SP)
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, P1 Series (Domae)
Model Number P1-25/EA/SVB
Rated Current (In) 25 A
Number of Poles 2-Pole (1P + N)
Rated Operational Voltage (Ue) 230V AC (Single-Phase + Neutral)
Rated Insulation Voltage (Ui) 400V AC
Breaking Capacity (Icn) 25 kA (25,000 A) at 230/400V AC
Tripping Characteristic Type A (Instantaneous trip: 2-3 x In)
Mechanical Life 20,000 operations
Electrical Life 10,000 operations
Mounting Standard 35mm DIN Rail (EN 60715)
Auxiliary Indication EA - Standard ON/OFF flag indicator
Terminal Type SVB - Shrouded Terminal Barrier (Finger Protection) for enhanced safety. Suitable for solid and stranded conductors.
Standards Compliance IEC/EN 60898-1
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, NZM Series
Model Number NZMN3-AE630
Rated Current (In) 630 A (This is the frame size. The adjustable electronic trip unit can be set to a specific value up to 630A).
Rated Ultimate Breaking Capacity (Icu) Typically 50 kA / 65 kA at 415V AC (Please confirm with the specific datasheet for your voltage and certification).
Number of Poles 3-Pole
Rated Operational Voltage (Ue) Up to 690V AC
Trip Unit Type AE - Advanced Electronic Trip Unit with LCD Display
Protection Functions L - Long-time Delay (Overload)
S - Short-time Delay (Short-Circuit)
I - Instantaneous (Short-Circuit)
G - Ground-Fault (Earth Leakage)
Adjustable Settings All protection functions (L, S, I, G) are fully adjustable for current and time delay, allowing for precise selective coordination.
Standard Compliance IEC/EN 60947-2
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, DILM Series
Model Number DILM25-01C
Rated Operational Current (Ie) 25 A at AC-3, 400V
Rated Thermal Current (Ith) 25 A
Poles (Main Circuit) 3 (Normally Open)
Auxiliary Contacts 1 NO (Normally Open) - Fixed
Rated Operational Voltage (Ue) Up to 690V AC
Control Coil Voltage "C" denotes a standard DC voltage range. The specific voltage must be ordered (e.g., 24V DC, 110V DC).
Utilization Categories AC-3: Squirrel cage motors: Starting, switching off during running (~ 1.5 million operations)
AC-1: Non-inductive or slightly inductive loads (~ 10 million operations)
Motor Rating (at 400V AC) 15 kW / 20 HP
Short-Circuit Protection Must be coordinated with fuses or circuit breakers.
Mechanical Life ~ 15 million operations
Electrical Life (AC-3) ~ 1.5 million operations
Mounting Standard 35mm DIN Rail (EN 60715) or screw mounting
Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14
Terminal Type Cage Clamp / Screw Clamp
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-D25/3-NA
Fuse Class & Rating Class D
Rated Current: 25 A
Rated Voltage: 600V AC / 300V DC
Number of Poles / Quantity 3 pieces (Typically supplied as a 3-pole set for a 3-phase application)
Type Time-Delay (Dual-Element)
Rated Voltage 600V AC / 300V DC
Interrupting Rating 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-10 (Class D), CSA C22.2 No. 248.10
Electrical Characteristics Current-Limiting: Yes
Time-Delay: Can typically withstand 500% of rated current for up to 10 seconds, allowing motor inrush currents to pass without nuisance opening.
Physical Dimensions Body: 1-1/4" x 2-1/4" (31.8mm diameter x 57.2mm length) - Edison Base (screws into a standard fuse holder)
Indicator / Feature NA - Indicates a non-indicating version. There is no visual indicator to show if the fuse has blown.
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-C6/3-NA
Fuse Class & Rating Class CC
Rated Current: 6 A
Rated Voltage: 600V AC
Number of Poles / Quantity 3 pieces (Typically supplied as a 3-pole set for a 3-phase application)
Type Fast-Acting (Non-Time-Delay)
Rated Voltage 600V AC / 300V DC
Rated Breaking Capacity (Interrupting Rating) 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4
Electrical Characteristics Current-Limiting: Yes
Melting I²t (6A): Very low, providing excellent component protection.
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting / Fuse Holder Requires a compatible Class CC fuse holder or fuse block (e.g., Eaton FHCC100, KRP-C-100SP)
Indicator / Feature NA - Indicates a non-indicating version. There is no visual indicator to show if the fuse has blown.
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-C13/2-RT
Fuse Class & Rating Class CC
Rated Current: 13 A
Rated Voltage: 600V AC
Number of Poles / Quantity 2 pieces (Typically supplied as a 2-pole set)
Type Fast-Acting (Non-Time-Delay)
Rated Voltage 600V AC / 300V DC
Rated Breaking Capacity (Interrupting Rating) 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4
Electrical Characteristics Current-Limiting: Yes
Melting I²t (13A): Very low, providing excellent component protection.
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting / Fuse Holder Requires a compatible Class CC fuse holder or fuse block (e.g., Eaton FHCC100, KRP-C-100SP)
Indicator / Feature RT - Rectangular Target (Visual Blown Indicator). A indicator pops out to provide a clear visual signal that the fuse has blown.
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-C2/3-RT
Fuse Class & Rating Class CC
Rated Current: 2 A
Rated Voltage: 600V AC
Number of Poles / Quantity 3 pieces (Typically supplied as a 3-pole set for a 3-phase application)
Type Fast-Acting (Non-Time-Delay)
Rated Voltage 600V AC / 300V DC
Rated Breaking Capacity (Interrupting Rating) 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4
Electrical Characteristics Current-Limiting: Yes, extremely effective due to the low current rating.
Melting I²t (2A): Exceptionally low, providing the highest level of component protection.
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting / Fuse Holder Requires a compatible Class CC fuse holder or fuse block (e.g., Eaton FHCC100, KRP-C-100SP)
Indicator / Feature RT - Rectangular Target (Visual Blown Indicator). An indicator pops out to provide a clear visual signal that the fuse has blown.
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-C25/2-RT
Fuse Class & Rating Class CC
Rated Current: 25 A
Rated Voltage: 600V AC
Number of Poles / Quantity 2 pieces (Typically supplied as a 2-pole set)
Type Fast-Acting (Non-Time-Delay)
Rated Voltage 600V AC / 300V DC
Rated Breaking Capacity (Interrupting Rating) 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4
Electrical Characteristics Current-Limiting: Yes
Melting I²t (25A): Low, providing good component protection.
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting / Fuse Holder Requires a compatible Class CC fuse holder or fuse block (e.g., Eaton FHCC100, KRP-C-100SP)
Indicator / Feature RT - Rectangular Target (Visual Blown Indicator). An indicator pops out to provide a clear visual signal that the fuse has blown.
Technical Parameters
Parameter Category Description / Value
Brand & Series Eaton, FAZ Series (Bussmann)
Model Number FAZ-C3/3-NA-AS
Fuse Class & Rating Class CC
Rated Current: 3 A
Rated Voltage: 600V AC
Number of Poles / Quantity 3 pieces (Typically supplied as a 3-pole set for a 3-phase application)
Type Time-Delay (Anti-Surge)
Rated Voltage 600V AC / 300V DC
Rated Breaking Capacity (Interrupting Rating) 200 kA AC (200,000 Amps) at 600V AC
Approvals / Standards UL 248-4 (Class CC), CSA C22.2 No. 248.4
Electrical Characteristics Current-Limiting: Yes
Time-Delay: Can withstand temporary overloads (e.g., 200% of rating) for a short duration.
Physical Dimensions Body: 13/32" x 1-1/2" (10.3mm diameter x 38.1mm length)
Mounting / Fuse Holder Requires a compatible Class CC fuse holder or fuse block (e.g., Eaton FHCC100, KRP-C-100SP)
Indicator / Feature NA - Non-Indicating. No visual indicator.
AS - Anti-Surge (Time-Delay characteristic).