Products
Products
home
___FISHER
FISHER™ 67C
Key Parameters Category Parameter Description / Typical Values Actuator Type Type Pneumatic Spring-Return Piston Actuator (Single-Acting). Action Fail-Closed (Air-to-Open) or Fail-Open (Air-to-Close). Performance Air Supply Pressure Standard operating range: 40 to 120 psig (2.8 to 8.3 bar). Output Torque Varies with air supply pressure and specific model. Provides high torque for its size. Spring Ranges Multiple spring ranges are available to provide the required fail-safe torque. Environmental Operating Temperature Standard: -4°F to +180°F (-20°C to +82°C). High-temperature options available. Materials Housing & Piston Aluminum with corrosion-resistant coating. Spring Coated steel. Accessories Positioner Mounting Designed for direct mounting of Fisher rotary positioners (e.g., DVC6000, 1061). Other Accessories Limit switches, solenoid valves, pressure regulators, etc.

More details >> Request a Quote >>
___FISHER
FISHER™ 64
Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) 125 psig (8.6 bar). Outlet Pressure (P2) Range Adjustable via spring selection. Common ranges span from 3.5" w.c. to 20 psig (approx. 0.87 kPa to 1.4 bar). Capacity Flow Coefficient (Cv) Low to moderate Cv, suitable for its intended applications. Size & Connections Pipe Size Typically 1/2 inch to 1-1/4 inch. End Connections Threaded (NPT). Materials Body Material Aluminum. Internal Components Stainless Steel, Synthetic Rubber Diaphragm. Safety Features Overpressure Protection (OPP) Integral Internal Relief Valve is a common optional feature. Environment Operating Temperature Standard for gas service (e.g., -20°F to 150°F / -29°C to 66°C).

More details >> Request a Quote >>
___FISHER
FISHER™ BAUMANN™ 24000CVF
Key Parameters Category Parameter Description / Typical Values Valve Body & Size Valve Body Style Top-guided, balanced trim, cage-style globe valve. Size Range 1/2 inch (DN15) to 2 inches (DN50). End Connections Flanged (ANSI Class 150 & 300). Pressure & Temperature Pressure Rating ANSI Class 150 and 300. Temperature Range Standard: -20°F to +450°F (-29°C to +232°C). Flow Characteristics Flow Characteristics Linear, Equal Percentage, Modified Percentage (via interchangeable cage). Flow Coefficient (Cv) A range of Cv values available based on trim size. Leakage Class Leakage Class ANSI/FCI 70-2 Class IV (standard metal seat). Class VI available with soft seats. Materials Body Materials Carbon Steel (WCB), Stainless Steel (CF8M/316). Trim Materials Stainless Steel (standard). Actuator Actuator Type Typically paired with a compact Fisher Baumann 1051/1052 pneumatic actuator or other spring-diaphragm actuators.

More details >> Request a Quote >>
___FISHER
FISHER™ BAUMANN™ 24000SVF
Key Parameters Category Parameter Description / Typical Values Valve Body & Size Valve Body Style Single-ported, top-guided globe valve. Size Range 1/2 inch (DN15) to 2 inches (DN50). End Connections Flanged (ANSI Class 150 & 300). Pressure & Temperature Pressure Rating ANSI Class 150 and 300. Temperature Range Standard: -20°F to +450°F (-29°C to +232°C). Flow Characteristics Flow Characteristics Linear or Equal Percentage (via plug design). Flow Coefficient (Cv) A range of Cv values available based on trim size. Leakage Class Leakage Class ANSI/FCI 70-2 Class IV (standard metal seat). Class VI available with soft seats. Materials Body Materials Carbon Steel (WCB), Stainless Steel (CF8/304, CF8M/316). Trim Materials Stainless Steel (standard). Actuator Actuator Type Typically paired with a compact Fisher Baumann 1051/1052 pneumatic actuator or other spring-diaphragm actuators.

More details >> Request a Quote >>
___FISHER
FISHER™ TYPE EZR
Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) 125 psig (8.6 bar). Outlet Pressure (P2) Range Adjustable via spring selection. Common ranges span from 3.5" w.c. to 20 psig (approx. 0.87 kPa to 1.4 bar). Capacity Flow Coefficient (Cv) Low to moderate Cv, suitable for its intended applications. Size & Connections Pipe Size Typically 1/2 inch to 1-1/4 inch. End Connections Threaded (NPT). Materials Body Material Aluminum. Internal Components Stainless Steel, Synthetic Rubber Diaphragm. Safety Features Overpressure Protection (OPP) Integral Internal Relief Valve is a common optional feature. Environment Operating Temperature Standard for gas service (e.g., -20°F to 150°F / -29°C to 66°C).

More details >> Request a Quote >>
___FISHER
FISHER™ P700
Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) Up to 1440 psig (100 bar). Outlet Pressure (P2) Range Configurable via pilot selection. Designed for high outlet pressures, often ranging from hundreds to over a thousand psig. Capacity Flow Coefficient (Cv) Extremely high Cv values. For example, a 6" P700 can have a Cv of over 1500. Accuracy & Droop Excellent, typically within ±1-2% of the set point due to the pilot-operated design. Size & Connections Pipe Size 2 inches (DN50) to 8 inches (DN200). End Connections Flanged (ANSI Class 600, 900, 1500). Materials Body Material Forged Steel (standard for high pressure). Trim Materials Stainless Steel. Pilot & Safety Pilot Types Reducing Pilot, Monitor Pilot, Dome-Loaded Pilot. Safety System Almost always installed upstream with a Fisher PSL or PSS Slam-Shut Valve for critical overpressure protection. Environment Operating Temperature Standard: -20°F to +150°F (-29°C to +66°C).

More details >> Request a Quote >>
___FISHER
FISHER™ TYPE P650
Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) Up to 400 psig (28 bar). Outlet Pressure (P2) Range Highly configurable via pilot selection. Common ranges from a few psig up to 250 psig. Capacity Flow Coefficient (Cv) High Cv values. For example, a 6" P650 can have a Cv of over 1000. Accuracy & Droop Excellent, typically within ±1-2% of the set point. Size & Connections Pipe Size 2 inches (DN50) to 12 inches (DN300). End Connections Flanged (ANSI Class 150 to 600). Materials Body Material Cast Iron or Ductile Iron. Trim Materials Stainless Steel. Pilot & Safety Pilot Types Reducing Pilot, Monitor Pilot, Dome-Loaded Pilot. Safety System Designed to be paired with external Slam-Shut Valves (PSL/PSS) for absolute overpressure protection. Environment Operating Temperature Standard: -20°F to +150°F (-29°C to +66°C).

More details >> Request a Quote >>
___FISHER
FISHER™ TYPE 63EG
Key Parameters Category Parameter Description / Typical Values Input & Control Control Signal 4-20 mA DC. Control Function Electronic setpoint for pressure reduction. Pressure Ratings Maximum Inlet Pressure (P1) 400 psig (28 bar). Outlet Pressure (P2) Range Determined by the internal pilot spring. Adjustable via the 4-20 mA signal across the spring's range. Capacity Flow Coefficient (Cv) High Cv values, similar to other regulators in its size class (e.g., a 2" size has a Cv of ~65). Size & Connections Pipe Size 3/4 inch to 4 inches. End Connections Threaded (NPT) or Flanged. Materials Body Material Cast Iron. Internals Stainless Steel. Electrical I/P Transducer Air Supply Requires a clean, dry instrument air supply (typically 20-100 psig).

More details >> Request a Quote >>
___FISHER
FISHER™ EZR
Key Parameters Category Parameter Description / Typical Values Pressure Ratings Maximum Inlet Pressure (P1) 125 psig (8.6 bar). Outlet Pressure (P2) Range Adjustable via spring selection. Common ranges span from 3.5" w.c. to 20 psig (approx. 0.87 kPa to 1.4 bar). Capacity Flow Coefficient (Cv) Low to moderate Cv, suitable for its intended applications. Size & Connections Pipe Size Typically 1/2 inch to 1-1/4 inch. End Connections Threaded (NPT). Materials Body Material Aluminum. Internal Components Stainless Steel, Synthetic Rubber Diaphragm. Safety Features Overpressure Protection (OPP) Integral Internal Relief Valve is a common optional feature. Environment Operating Temperature Standard for gas service (e.g., -20°F to 150°F / -29°C to 66°C).

More details >> Request a Quote >>
___FISHER
FISHER IC2
Key Parameters Category Parameter Description / Typical Values Compatibility Supported Protocols HART® (Highway Addressable Remote Transducer). Compatible Instruments Fisher FIELDVUE Digital Valve Controllers and other HART communication devices. Electrical Power Supply Loop-powered (draws power from the 4-20 mA loop of the connected HART instrument). Loop Requirements Requires a minimum loop voltage and resistance to operate (e.g., typically > 11 VDC and < 1100 Ω). Connectivity Computer Connection USB or Serial (RS-232) via appropriate cables. Field Connection Standard test lead connectors. Software Required Software Fisher FIELDVUE DVC Setup and Diagnostics Software or Emerson AMS Device Manager. Environment Operating Temperature Standard for field use (e.g., 32°F to 140°F / 0°C to 60°C).

More details >> Request a Quote >>