Products
Products
home
___FISHER
DVC6200SIS
Parameter Specification Model DVC6200 SIS Product Line Fisher FIELDVUE® Type Digital Valve Controller / Positioner Certification SIL 2 capable per IEC 61508/61511 (hardware fault tolerance 0 with SFF > 90%). SIL 3 capable for specific architectures (e.g., HFT 1). Certified by exida. Input Signal 4-20 mA with HART® 7 protocol; Digital (via FOUNDATION™ fieldbus H1 or PROFIBUS® PA available as options) Supply Pressure Up to 150 psi (10.3 bar) for single-acting; Up to 125 psi (8.6 bar) for double-acting Air Delivery Capacity High Capacity: Up to 110 scfm (187 Nm³/h) Standard Capacity: Up to 32 scfm (54 Nm³/h) Output Action Single-acting (for spring-return actuators) or Double-acting Fail-safe Action De-energize to trip. Upon loss of power or signal, it exhausts air from the actuator to drive the valve to its safe state. Pilot Valve Type Piezoelectric, low power consumption Operating Temperature Standard: -40° to 185°F (-40° to 85°C) Extended: -60° to 185°F (-51° to 85°C) with optional heater Enclosure Rating NEMA 4X, Type 4, IP66/67 Communication HART 7 (via 4-20 mA signal), Local Magnetic Communicator, and/or FIELDVUE DVC6200 SIS Setup Software Diagnostics Built-in Partial Stroke Test (PST), travel, pressure, and step response data collection, performance alerts. Materials Aluminum enclosure with epoxy paint; Stainless steel internal parts and fittings. Safety Manual Available and required for proper use in SIS loops.

More details >> Request a Quote >>
___FISHER
47B9380X022
Technical Parameters Parameter Value / Description Fisher Model Number 47B9380X022 Type Pilot-Operated Pressure Regulator (Pilot) Primary Function Acts as a control pilot for a main valve or as a standalone regulator. Pilot Supply Source Typically tapped from upstream pressure or an external gas supply. Body Material Aluminum Trim Materials Standard corrosion-resistant materials (e.g., stainless steel & elastomers). Pressure Rating Typically 1440 psig (100 bar) or similar high pressure. Outlet Pressure Range (P2) Determined by the internal spring. The "X022" suffix likely specifies a particular range. Common 47B series ranges: 5-250 psig, 20-500 psig, etc. Must be confirmed from order records. Inlet Pressure (P1) Up to the pressure rating (e.g., 1440 psig). Connections Typically 1/4" or 1/2" NPT Female Diaphragm Material Typically Nylon-coated fabric or Viton (FKM).

More details >> Request a Quote >>
___FISHER
DVC6030
Technical Parameters Parameter Value / Description Fisher Model Number DVC6030 Product Line FIELDVUE Type Digital Valve Controller (Positioner) Action Single-Acting Input Signal 4-20 mA DC, with HART protocol digital communication Supply Pressure Up to 150 psig (10.3 bar) Output Pressure Up to supply pressure Air Consumption Typically < 0.15 SCFM (0.25 Nm³/hr) at steady state Accuracy Better than ±0.5% of span Dead Band Better than 0.05% of span Travel Range Configurable, typically supports 0.2 to 4.0 inches (5 to 100 mm) Ambient Temperature -40°F to +185°F (-40°C to +85°C) Enclosure Rating NEMA 4X (IP66) Communication HART 5/6/7 Mounting Linear (via mounting kit); can be adapted for some rotary valves

More details >> Request a Quote >>
___FISHER
167DA-85
Technical Parameters Parameter Value / Description for 167DA-85 Fisher Model Number 167DA-85 Type Direct-Operated Pressure Reducing Regulator Orifice Size / Connection 1/2 inch Female NPT - This is the key identifier for the -85 suffix. Body Material Diecast Zinc Trim Materials Typically includes EPDM gaskets, Neoprene diaphragm, and reinforced elastomer valve head. Max Inlet Pressure (P1) 400 psig (28 bar) Outlet Pressure Range (P2) 5 to 125 psig (0.3 to 8.6 bar) - This is the most common spring range for this model. Temperature Range -20°F to +150°F (-29°C to +66°C) Flow Coefficient (Cv) Approximately 3.0 (varies with specific pressure drop)

More details >> Request a Quote >>
___FISHER
1V659905092
Technical Parameters Parameter Value / Description Fisher Model Number 1V659905092 Type Pilot-Operated Pressure Reducing Regulator Valve Size (Pipe Size) 4 inch (4") Orifice Size Correlated to valve size (e.g., 4 inch) End Connections Flanged (Typically RF or RTJ) Pressure Rating (ANSI Class) Class 300 Body Material Carbon Steel (e.g., WCB) Trim Material Standard Trim (Typically 304 Stainless Steel) Diaphragm Material Typically Nitrile (Buna-N) for standard service. Max Inlet Pressure (P1) Up to 720 psig (50 bar) approximately (based on Class 300 rating). Outlet Pressure Range (P2) Determined by the spring range. Common examples: 20-125 psig, 50-250 psig, or other ranges. Must be confirmed from order records. Temperature Range Standard: -20°F to +150°F (-29°C to +66°C) with standard elastomers.

More details >> Request a Quote >>
___FISHER
1V659805292
Technical Parameters Parameter Value / Description Fisher Model Number 1V711606242 Type Pilot-Operated Pressure Reducing Regulator Valve Size (Port Size) 2 inch (2") - Note: This is the port size, not necessarily the pipe size. Orifice Size Typically 2 inch (Depending on trim) End Connections Flanged (RF or RTJ are common) Pressure Rating (ANSI Class) Class 300 (or as specified) Body Material Carbon Steel (e.g., WCB) Trim Material Standard Trim (e.g., 304 Stainless Steel) Main Diaphragm Material Typically Nitrile (Buna-N) for standard service. Max Inlet Pressure (P1) Varies with body rating, e.g., up to 750 psig (51.7 bar) for Class 300. Outlet Pressure Range (P2) Depends on the installed spring range. Example Ranges: 3 to 9 psig, 8 to 30 psig, 20 to 60 psig, etc. Temperature Range Standard: -20°F to +150°F (-29°C to +66°C) with standard elastomers.

More details >> Request a Quote >>
___FISHER
1V711606242
Technical Parameters Parameter Value / Description Fisher Model Number 1V711606242 Type Pilot-Operated Pressure Reducing Regulator Valve Size (Port Size) 2 inch (2") Orifice Size Typically 2 inch (Depending on trim) End Connections Flanged (RF or RTJ are common) Pressure Rating (ANSI Class) Class 300 (or as specified) Body Material Carbon Steel (e.g., WCB) Trim Material Standard Trim (e.g., 304 Stainless Steel) Main Diaphragm Material Typically Nitrile (Buna-N) or other elastomers for standard service. Pilot Diaphragm Material Typically Nitrile (Buna-N) Max Inlet Pressure (P1) Varies with body rating, e.g., up to 750 psig (51.7 bar) for Class 300. Outlet Pressure Range (P2) Depends on the specific spring range installed. Example Spring Ranges: 3 to 9 psig, 8 to 30 psig, 20 to 60 psig, etc. Temperature Range Standard: -20°F to +150°F (-29°C to +66°C) with standard elastomers. Higher temperatures with special materials. Pilot Connection Size 1/2 inch NPT Leakage Class Class IV (Metal-to-metal seat) or Class VI (Soft seat) depending on trim.

More details >> Request a Quote >>
___FISHER
2E800002202
Key Specifications / Parameters Part Number: 2E800002202 Product Type: Diaphragm (actuator component) Compatible Actuator Series: Fisher Type 667 Actuator Size Fitment: Size 30 Material: Nitrile elastomer (NBR) Approximate Diameter: ~30 inches for the diaphragm (as listed for size 30) Application: Replacement diaphragm for size 30 pneumatic actuator in valve systems Status: Discontinued/Legacy part (as indicated in some listings)

More details >> Request a Quote >>
___FISHER
2E669902202
Key Specifications / Parameters Part Number: 2E 669902202 Product Type: Actuator diaphragm Material: Nitrile elastomer (NBR) Compatible Actuator Model: Fisher Type 667, size range 34/40 Diameter: ~13.125 inches (13‑1/8″) Mounting Hole Count: 16 holes around the periphery Weight: ~0.65 lbs (as listed) Status: Discontinued by manufacturer (legacy spare part)

More details >> Request a Quote >>
___FISHER
2E859802202
Key Specifications / Parameters Part Number: 2E859802202 Product Type: Actuator diaphragm Compatible Actuator Series: Fisher Type 667 Actuator Size Fitment: Size 60 Material: Nitrile elastomer (NBR) Diameter Approximate: 18 5/8 inches (~473 mm) Mounting Hole Count: 24 holes around the periphery (for Size 60) Application: Replacement part for industrial process control valve actuators where a properly functioning diaphragm is required for accurate valve actuation and response.

More details >> Request a Quote >>