Technical Parameters
Parameter Specification
Model HNM3-3HU
Rated Current (Iₙ) 63 A (typical - confirm specific rating)
Number of Poles 3P (Three Pole)
Rated Voltage 400 V AC
Rated Frequency 50/60 Hz
Breaking Capacity 10 kA (at 230/400 V AC)
Tripping Characteristic C Curve (Medium starting current)
Electrical Life 6,000 operations
Mechanical Life 20,000 operations
Mounting DIN Rail (35mm)
Terminal Type Screw Clamp
Wire Range 16 mm² - 25 mm²
Standards & Approvals IEC 60898-1, CE
Technical Parameters
Parameter Specification
Model N2-200
Rated Current (Iₙ) 200 A
Number of Poles 2P (Two Pole)
Rated Voltage (Uₑ) 600 V AC
Rated Frequency 50/60 Hz
Breaking Capacity 35 kA (at 480 V AC)
Trip Unit Type Thermal-magnetic
Rated Insulation Voltage (Uᵢ) 690 V
Rated Impulse Voltage (Uᵢₘₚ) 6 kV
Electrical Life 5,000 operations
Mechanical Life 10,000 operations
Mounting Fixed Type
Terminal Type Screw Clamp
Wire Range 3/0 AWG - 250 kcmil
Standards & Approvals UL 489, IEC 60947-2, CSA 22.2
Technical Parameters
Parameter Specification
Model NZMH2-A200-NA
Rated Current (Iₙ) 200 A
Number of Poles 2P (Two Pole)
Rated Voltage (Uₑ) 600 V AC
Rated Frequency 50/60 Hz
Breaking Capacity (Iᶜᵂ) 35 kA (at 480 V AC)
Trip Unit Type Thermal-magnetic (TM)
Rated Insulation Voltage (Uᵢ) 690 V
Rated Impulse Voltage (Uᵢₘₚ) 6 kV
Electrical Life 5,000 operations
Mechanical Life 10,000 operations
Mounting Fixed Type
Terminal Type Screw Clamp
Wire Range 3/0 AWG - 250 kcmil
Standards & Approvals UL 489, IEC 60947-2, CSA 22.2
Technical Parameters
Parameter Specification
Model NZMS2-M125
Rated Current (Iₙ) 125 A
Number of Poles 2P (Two Pole)
Rated Voltage (Uₑ) 500 V AC
Rated Frequency 50/60 Hz
Breaking Capacity (Iᶜᵂ) 25 kA (at 400 V AC)
Trip Unit Type Thermal-magnetic
Rated Insulation Voltage (Uᵢ) 690 V
Electrical Life 5,000 operations
Mechanical Life 10,000 operations
Mounting Fixed Type
Terminal Type Screw Clamp
Wire Range 1/0 AWG - 250 kcmil
Standards & Approvals IEC 60947-2, CCC
Technical Parameters
Parameter Specification
Model NZMN2-A250-NA
Rated Current (Iₙ) 250 A
Number of Poles 2P (Two Pole)
Rated Voltage (Uₑ) 600 V AC
Rated Frequency 50/60 Hz
Breaking Capacity (Iᶜᵂ) 65 kA (at 480 V AC)
Trip Unit Type Thermal-magnetic (TM)
Rated Insulation Voltage (Uᵢ) 690 V
Rated Impulse Voltage (Uᵢₘₚ) 6 kV
Electrical Life 5,000 operations
Mechanical Life 10,000 operations
Mounting Fixed Type
Terminal Type Screw Clamp
Wire Range 250 kcmil - 4/0 AWG
Standards & Approvals UL 489, IEC 60947-2, CSA 22.2
Technical Parameters
Parameter Specification
Model STN0.1(400/230)
Product Type Multi-function Electronic Time Relay
Supply Voltage 24-240 V AC/DC (wide range)
Special Voltage Rating 400/230 V AC (as specified)
Timing Range 0.1s - 300h (multiple sub-ranges)
Accuracy ±0.5% of set value ± 20 ms
Output Type 1 changeover relay contact (SPDT)
Switching Capacity 8 A / 250 V AC (resistive)
Number of Functions 15+ timing functions
Repeat Accuracy ≤ 0.5% + 20 ms
Mounting DIN Rail (35mm)
Terminal Type Screw clamp
Operating Temperature -20°C to +60°C
Storage Temperature -40°C to +70°C
Protection Degree IP40 (front), IP20 (terminals)
Standards & Approvals IEC/EN 61812, UL 508, CSA, CE, cULus
Technical Parameters
Parameter Specification
Model BZMX2N-3-AX63-S08
Rated Current (Iₙ) 63 A
Frame Size 63 A
Number of Poles 3P (Three Pole)
Rated Voltage (Uₑ) 600 V AC
Rated Frequency 50/60 Hz
Breaking Capacity 35 kA (at 480 V AC)
Trip Unit Type Electronic (AX type)
Rated Insulation Voltage (Uᵢ) 690 V
Rated Impulse Voltage (Uᵢₘₚ) 6 kV
Protection Functions Long-time, Short-time, Instantaneous
Communication Protocol Optional communication modules
Mounting Fixed Type
Terminal Type Screw Clamp
Wire Range 8 AWG - 2 AWG
Standards & Approvals UL 489, IEC 60947-2, CSA 22.2
Technical Parameters
Parameter Specification
Model BZMX2N-3-AA160-S08
Rated Current (Iₙ) 160 A
Frame Size 160 A
Number of Poles 3P (Three Pole)
Rated Voltage (Uₑ) 600 V AC
Rated Frequency 50/60 Hz
Breaking Capacity 65 kA (at 480 V AC)
Trip Unit Type Electronic (AA type)
Rated Insulation Voltage (Uᵢ) 690 V
Rated Impulse Voltage (Uᵢₘₚ) 8 kV
Protection Functions Long-time, Short-time, Instantaneous, Ground Fault
Communication Protocol Modbus, Ethernet (depending on module)
Mounting Fixed Type
Terminal Type Screw Clamp
Wire Range 1/0 AWG - 250 kcmil
Standards & Approvals UL 489, IEC 60947-2, CSA 22.2
Technical Parameters
Parameter Specification
Model BZMX2N-3-AA250-S08
Rated Current (Iₙ) 250 A
Frame Size 250 A
Number of Poles 3P (Three Pole)
Rated Voltage (Uₑ) 600 V AC
Rated Frequency 50/60 Hz
Breaking Capacity 65 kA (at 480 V AC)
Trip Unit Type Electronic (AA type)
Rated Insulation Voltage (Uᵢ) 690 V
Rated Impulse Voltage (Uᵢₘₚ) 8 kV
Protection Functions Long-time, Short-time, Instantaneous, Ground Fault
Communication Protocol Modbus, Ethernet (depending on module)
Mounting Fixed Type
Terminal Type Screw Clamp
Wire Range 250 kcmil - 4/0 AWG
Standards & Approvals UL 489, IEC 60947-2, CSA 22.2
Technical Parameters
Parameter Specification
Model NZMH2-A160
Rated Current (Iₙ) 160 A
Number of Poles 2P (Two Pole)
Rated Voltage (Uₑ) 600 V AC
Rated Frequency 50/60 Hz
Breaking Capacity (Iᶜᵂ) 35 kA (at 480 V AC)
Trip Unit Type Thermal-magnetic (TM)
Rated Insulation Voltage (Uᵢ) 690 V
Rated Impulse Voltage (Uᵢₘₚ) 6 kV
Electrical Life 5,000 operations
Mechanical Life 10,000 operations
Mounting Panel Mount (Fixed Type)
Terminal Type Screw Clamp
Wire Range 1/0 AWG - 250 kcmil
Standards & Approvals UL 489, IEC 60947-2, CSA 22.2