Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZM1-4-XFIU (This is a base model; full code specifies voltage)
Product Line NZM (Accessory for)
Device Type Combination Accessory (Shunt Trip/UVR + Auxiliary + Alarm)
Compatible Breaker Frame NZM1, 4-Pole
Mounting Mounts directly onto the compatible 4-pole NZM1 breaker
Full Ordering Code Example NZM1-4-XFIU230AC (This would specify a 230V AC operating voltage for the shunt trip/UVR coil). The voltage must be specified.
Components Included • 1x Shunt Trip/Under-Voltage Release (XF)
• 1x Auxiliary Contact (I): Specific configuration (e.g., 1 NO + 1 NC)
• 1x Alarm Contact (U): 1 NO (on fault trip only)
Shunt Trip/UVR Voltage Available for common AC voltages (e.g., 230V, 400V AC). Must be specified in full order code.
Auxiliary & Alarm Contact Rating Suitable for control circuits. Typical rating: e.g., 3A @ 230V AC (AC-15). Must be verified from datasheet.
Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.
Technical Specifications
Parameter Specification / Typical Value (To be Verified)
Manufacturer / Brand Eaton
Model Number JGS310032G
Product Line Power Xpert Gateway 3000
Primary Function Data Gateway / Protocol Converter
Supported Protocols (Slave Side) Likely Modbus RTU, BACnet MS/TP, DeviceNet (to connect to field devices)
Supported Protocols (Master Side) Likely Modbus TCP/IP, BACnet/IP, SNMP, Web Services (to connect to central systems)
Number of Connected Devices Capable of connecting to dozens or hundreds of IEDs.
Hardware Interfaces Typically includes Ethernet port(s), and multiple serial ports (RS-232/RS-485).
Power Supply Typically 24V DC or 100-240V AC. Must be verified.
Enclosure Designed for DIN-rail mounting inside a control panel.
Standards Compliance Relevant for industrial communication and electrical equipment.
Technical Specifications
Parameter Specification / Typical Value (To be Verified)
Manufacturer / Brand Eaton
Model Number JGS3160AAG
Product Line Power Xpert Gateway 3000
Primary Function Data Gateway / Protocol Converter
Supported Protocols (Slave Side) Likely Modbus RTU, BACnet MS/TP, DeviceNet, etc. (to connect to field devices)
Supported Protocols (Master Side) Likely Modbus TCP/IP, BACnet/IP, SNMP, Web Services (to connect to central systems)
Hardware Interfaces Specific combination defined by "60AAG" (e.g., Dual Ethernet, multiple RS-485 ports).
Power Supply Typically 24V DC or 100-240V AC. Must be verified.
Enclosure DIN-rail mountable.
Configuration Via web interface or dedicated software tool.
Standards Compliance Relevant for industrial communication and electrical equipment.
Technical Specifications
Parameter Specification / Typical Value (To be Verified)
Manufacturer / Brand Eaton
Model Number 3VF3212-1MW41-0AA0
Product Line 3VF Control and Auxiliary Contactors
Rated Operational Current (Ie) e.g., 10 A (for each contact, at a specific voltage like 230V AC)
Contact Configuration 4 Change-Over (CO) contacts (Typically 4 NO + 4 NC)
Rated Operational Voltage (Ue) For the contacts: Up to 690 V AC
Control Coil Voltage DC Voltage (The exact value, e.g., 24V DC or 110V DC, is encoded in "1MW41" and must be confirmed via datasheet).
Coil Type Latching / Bistable (Requires a pulse to switch state)
Mechanical Life Typically millions of cycles
Electrical Life Typically hundreds of thousands of cycles (depends on load)
Mounting DIN Rail Mount (35mm)
Standards Compliance IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number LT3400AAV
Product Line xComfort (Home & Building Automation)
Device Type System Controller / Gateway
Power Supply 230 V AC (Typical for "AAV" suffix)
System Communication Wireless (e.g., 2.4 GHz) with other xComfort devices
Network Connectivity Integrated Ethernet port for connection to a local area network (LAN) and the internet.
User Interface Configuration and control via web browser (web server) and/or mobile app.
Functions - Centralized control and monitoring
- Logic creation (e.g., "if-then" scenarios)
- Scheduling (time-based control)
- Remote access via internet
- Integration with other systems (e.g., via API)
Mounting DIN Rail Mount (in an electrical distribution board)
Standards Compliance Relevant for radio equipment and electrical safety.
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZM2-XDV
Product Line NZM (Accessory for)
Device Type Fixed Division Plate / Barrier
Compatible Breaker Frame NZM2 (for fixed-mounted breakers)
Material Typically robust, insulating material (e.g., high-grade plastic) or metal with appropriate insulation.
Color Typically Orange (common for safety-related parts in Eaton equipment).
Standards Compliance Helps the overall assembly comply with IEC 61439-1/2 for low-voltage switchgear and controlgear assemblies.
Technical Specifications
Parameter Specification / Typical Value (To be Verified)
Manufacturer / Brand Eaton
Base Model Number NZM2/3-XA (Incomplete - requires suffix)
Product Line NZM (Accessory for)
Device Type Auxiliary Contact Block
Compatible Breaker Frame NZM2, NZM3
Mounting Mounts directly onto the compatible NZM breaker
Example Complete Model NZM2/3-XA11AC/DC (1 NO + 1 NC contacts, AC/DC voltage)
NZM2/3-XA48AC/DC (2 NO + 2 NC contacts, AC/DC voltage)
Contact Configuration Defined by suffix (e.g., "11" = 1NO+1NC, "48" = 2NO+2NC)
Rated Operational Voltage (Ue) Defined by suffix (e.g., "AC/DC", "24DC", "230AC")
Utilization Category AC-15 (for AC coils), DC-13 (for DC coils)
Rated Current Typically a few Amperes (e.g., 3A @ 230V AC) for control circuits.
Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZM2/3-XA24AC/DC
Product Line NZM (Accessory for)
Device Type Auxiliary Contact Block
Compatible Breaker Frame NZM2, NZM3
Mounting Mounts directly onto the compatible NZM breaker
Contact Configuration 1 Normally Open (NO) + 1 Normally Closed (NC)
Rated Operational Voltage (Ue) Suitable for AC and DC control circuits. The specific maximum voltage (e.g., 230V AC/220V DC) must be confirmed from the datasheet.
Rated Thermal Current (Ith) e.g., 10 A
Utilization Category AC-15: For switching AC electromagnetic loads (e.g., contactor coils). DC-13: For switching DC electromagnetic loads.
Rated Current at AC-15 e.g., 3 A @ 230V AC (Please verify from manual)
Rated Current at DC-13 e.g., 0.5 A @ 220V DC (Please verify from manual)
Electrical Life Typically hundreds of thousands of operations.
Mechanical Life Typically millions of operations.
Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZM2/3-XUHIV208-240AC
Product Line NZM (Accessory for)
Device Type Under-Voltage Release (UVR)
Compatible Breaker Frame NZM2, NZM3
Mounting Mounts directly onto the compatible NZM breaker
Rated Operational Voltage (Ue) 208-240 V AC
Trip Threshold Typically trips when voltage drops to 35% - 70% of its rated operating voltage.
Reset Voltage The breaker can typically be reset once the voltage is restored to above approx. 85% of the rated voltage.
Power Consumption Continuously consumes a small amount of power when energized.
Frequency 50/60 Hz
Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.
Technical Specifications
Parameter Specification / Typical Value
Manufacturer / Brand Eaton
Model Number NZM1-XUHIVL (This is a base model; full code likely specifies voltage)
Product Line NZM (Accessory for)
Device Type Under-Voltage Release (UVR)
Compatible Breaker Frame NZM1
Mounting Mounts directly onto the compatible NZM1 breaker
Full Ordering Code Example NZM1-XUHIVL24AC (This would specify a 24V AC operating voltage). The voltage must be specified.
Typical Operating Voltages Available for common AC voltages (e.g., 24V, 48V, 110V, 230V AC). The specific voltage is CRITICAL and is defined in the full order code.
Trip Threshold Typically trips when voltage drops to 35% - 70% of its rated operating voltage.
Reset Voltage The breaker can typically be reset once the voltage is restored to above approx. 85% of the rated voltage.
Power Consumption Continuously consumes a small amount of power when energized.
Standards Compliance As part of the breaker assembly, it helps comply with IEC 60947-2.