Technical Parameters
Parameter Value Notes
Maximum Operating Pressure 350 bar 5,075 psi
Rated Flow Capacity 19 L/min 5 US gpm
Port Size NG06 CETOP 03 standard
Spool Configuration 3-position, 4-way Various center options
Solenoid Type Wet pin DC Standard construction
Manual Override Standard feature For emergency operation
Mounting ISO 4401 Standard interface
Fluid Compatibility Mineral-based hydraulic oil Petroleum-based fluids
Operating Temperature -20°C to +70°C -4°F to +158°F
Technical Parameters
Parameter Value Notes
Nominal Size 40 NG10 (CETOP 05) equivalent
Maximum Flow Rate 80 L/min 21 US gpm
Minimum Controlled Flow 1.5 L/min 0.4 US gpm
Maximum Operating Pressure 350 bar 5,075 psi
Control Signal 0-10V DC or 4-20mA Analog input with digital interface
Hysteresis < 1.5% Typical value
Linearity < 2% Typical value
Response Time < 30 ms To 90% of commanded value
Repeatability < 0.5% Typical value
Technical Parameters
Parameter Value Notes
Nominal Size 40 NG10 (CETOP 05) interface
Maximum Flow Rate 80 L/min 21 US gpm
Minimum Controlled Flow 1.5 L/min 0.4 US gpm
Maximum Operating Pressure 350 bar 5,075 psi
Control Signal 0-10V DC or 4-20mA Analog input with digital interface
Hysteresis < 1.5% Maximum value
Linearity < 2% Maximum deviation
Response Time < 30 ms 10-90% step response
Repeatability < 0.5% Typical value
Parameter Specification
Product Model XTOE1P6CGSS
Product Type Duplex Receptacle / Outlet
Grade Commercial Spec Grade
Current Rating 15 A
Voltage Rating 125 VAC
Poles & Wires 2-Pole, 3-Wire
Receptacle Configuration 5-15R (Two vertical slots and a round ground pin)
Tamper Resistance Yes (TR), complies with NEC requirements for safety.
Construction Material Stainless Steel body and faceplate
Color / Finish Stainless Steel (Brushed Satin look)
Wiring Type Side and Back Wire (Pressure Plate Clamp terminals for secure connections)
Mounting Standard Wall Mount
Compliant Standards UL Listed, cULus Listed, compliant with NEC and OSHA standards.
Special Features
Corrosion-resistant stainless steel construction.
Self-grounding (No separate ground wire needed to the mounting strap).
Parameter Specification
Product Model 13104RS5007
Product Line Cutler Hammer by Eaton
Product Type Emergency Stop Push Button Station
Button Type Mushroom Head, Emergency Stop (E-STOP)
Button Function Maintained Contact (latching); requires a twisting or pulling action to release after being pressed.
Button Diameter 50 mm (Large, highly visible and accessible)
Button Color Red
Contact Block Typically supplied as a N.O. (Normally Open) contact that opens when pressed (safety standard). Note: Configuration can vary; verifying the specific contact arrangement upon receipt is recommended.
Enclosure Rating NEMA 4X (Weatherproof, Watertight, Dusttight, Corrosion-Resistant)
Ingress Protection (IP) IP66 (Equivalent to NEMA 4X, protected against powerful water jets and dust.)
Enclosure Material Fiberglass Reinforced Polyester or similar robust, corrosion-resistant material.
Mounting Surface Mount
Operator Material Thermoplastic or Metal (designed for high impact and repeated use)
Applications Industrial machinery, manufacturing lines, processing plants, and any application requiring a highly visible and reliable emergency stop function.
Compliant Standards UL Listed, cULus Listed, conforms to relevant IEC and NEMA standards for safety devices.
Parameter Specification
Product Model 311574
Product Type Window-type, Fixed-mount Current Transformer (CT)
Rated Primary Current (Ipr) 400 A
Rated Secondary Current (Isr) 5 A
Frequency 50/60 Hz
Accuracy Class 0.5 or 1.0
Burden (Rated Output) e.g., 2.5 VA or 5 VA
Insulation / Voltage Rating e.g., 600 V to 1000 V
Window Diameter (Opening) e.g., 30 mm
Mounting Method Fixed mounting, typically with pre-drilled holes for bolts/screws.
Standards Compliance Complies with IEC 61869-1, IEC 60044-1, or equivalent ANSI/IEEE standards.
Applications
Electrical energy metering
Power monitoring systems
Motor load monitoring
Protective relaying
Material Typically a thermoset or thermoplastic insulated housing.
Parameter Specification Notes / Typical Value for this Series
Product Model NZM1/2-XCR-S/MODAN
Product Line NZM (Molded Case Circuit Breaker)
Rated Operational Voltage (Ue) Typically up to 690V AC
Rated Current (In) Depends on the Rating Plug. The frame size NZM1/2 supports a range (e.g., up to 63A or 125A). The actual current is set by a separate rating plug.
Rated Ultimate Breaking Capacity (Icu) Standard Breaking Capacity ("S") Specific kA value at a given voltage (e.g., 25kA @ 415V) must be verified from datasheet.
Trip Unit Type Electronic (XCR)
Protection Functions
L - Long-Time (Overload)
S - Short-Time (Short-Circuit)
I - Instantaneous
G - Ground Fault
All thresholds are adjustable.
Communication Capability Yes (Typically PROFIBUS-DP or Modbus) The "X" in XCR often denotes communication readiness. Requires a separate communication module.
Auxiliary Contacts Can be equipped Via add-on modules.
Mounting Fixed or Plug-in (as per MODAN kit) The "MODAN" kit facilitates specific mounting.
Standards Compliance IEC 60947-2, UL 489, etc.
Parameter Specification
Product Model FAZ-B63/3N
Product Line Eaton FAZ B-Series (Miniature Circuit Breaker)
Number of Poles 3 Poles + Neutral (3P+N)
Rated Current (In) 63 A
Tripping Characteristic B-Curve (Instantaneous tripping between 3 to 5 times rated current). Suitable for resistive and low inductive loads.
Rated Operational Voltage (Ue) 230/400 V AC
Rated Insulation Voltage (Ui) 500 V AC
Rated Impulse Withstanding Voltage (Uimp) 4 kV
Rated Breaking Capacity (Icn) Typically 10 kA at 230/400V AC according to IEC 60898-1. (Please confirm with local catalog as higher capacity versions may exist).
Standards IEC/EN 60898-1, IEC/EN 60947-2
Terminal Connection Suitable for cables up to 35 mm² (copper).
Mounting Standard DIN Rail (35 mm) mounting.
Mechanical Life Typically > 20,000 cycles
Electrical Life Typically > 10,000 cycles
Torque Screw Typically 3.0 N·m
Parameter Specification
Product Model LS-11DA
Product Type Heavy-Duty Limit Switch
Contact Arrangement 1 NO (Normally Open) + 1 NC (Normally Closed) - Single Circuit, Double Break
Contact Operation Maintained Contact
Switch Mechanism Slow Action (Snap-Action)
Rated Operational Current Typically 10 A @ 600 V AC / 0.5 A @ 600 V DC (Specific values depend on thermal and inductive load)
Electrical Life Typically 1 to 2 million operations (at rated load)
Mechanical Life Typically 10 million operations
Enclosure Rating NEMA 4, 4X, 6P, 13; IP67 (Dust-tight and protected against immersion)
Housing Material Typically Zinc Die Cast
Operating Head Various actuator types available (e.g., roller lever, plunger) - the "DA" suffix may specify a particular type.
Terminal Type Screw terminals
Conduit Opening Standard ½" NPT
Temperature Range Typically -20°C to +120°C (-4°F to +248°F)
Standards Compliance UL Listed, cULus Listed, CE