Model Code B-FXSUN-XROHS P0915FU Input Signal Type: Frequency / Tachometer Waveform: Sine Wave or Square Wave Amplitude Range: 200 mV RMS to 60 V RMS (typical) Frequency Range: 0.5 Hz to 12,000 Hz (12 kHz) Output Signal Type: 4-20 mA DC, 2-wire Load: Maximum 600 Ω (at 24V DC supply) Characteristic: Linear with input frequency. Power Supply Voltage Range: 20-30 V DC Power Consumption: Typically < 5 W Isolation Rating: 1500 V AC (between Input, Output, and Power Supply) Accuracy Typical: ±0.1% of span Response Time Configurable: Typically adjustable from 50 ms to 5.0 seconds. Safety Certifications Intrinsic Safety: Certified for Class I, Division 1, Groups A, B, C, D; Zone 0 by agencies such as FM, CSA, ATEX, and IECEx. Environmental Compliance RoHS: Compliant with the Restriction of Hazardous Substances directive. Operating Temperature -20°C to +70°C Mounting Standard 35 mm DIN Rail