Parameter Specification Notes / Explanation Model Series CV1 Port Size 1/8" NPT "16" in the model number typically corresponds to 1/8" Number of Ports 5 (1-Pressure, 2-Exhaust, 2-Work ports A & B) Number of Positions 3 Actuation Type Solenoid Operated, Air Pilot Spool/Center Position Closed Center (All Ports Blocked) This is the "P" type in the model code Voltage Must be specified Common options: 12 VDC, 24 VDC, 120 VAC, 240 VAC Operating Pressure Range 30 - 120 psi (2 - 8 bar) Typical for pneumatic valves Maximum Flow (Cv factor) ~ 0.5 Response Time ~ 20 - 50 ms Duty Cycle 100% Continuous Mounting Style Sub-base / Manifold Mount ISO 5599-1 standard Seal Material Standard: Nitrile (Buna-N) Coil Connection Conduit or DIN Form A With LED indicator