Technical Specifications Parameter Specification Notes / Interpretation Manufacturer / Series Eaton DG4V D03 / NG6 interface Model Number DG4V-3-33C-M-U-BX5-60 Valve Type Directional Control Valve Number of Ways / Positions 4-Way, 3-Position Spring Offset + Solenoid Centered + Detented Porting Size D03 (NG6) ISO 4401 standard Port Thread 7/16"-20 UNF Common for D03 size Actuation Type Solenoid Operated, Spring Offset from one side, Detented from the other Complex actuation. Solenoid Type Dual Solenoids Both are single solenoids. Spool Configuration -33C-: Spring Offset, Solenoid Center, Detented Pos1 (Spring): P→B & A→T Pos2 (Solenoid A): Defined by 'C' Pos3 (Solenoid B): Detented, flow path is typically P→A & B→T Center Position (when Solenoid A is energized) C: Likely a Tandem or Float type center The "C" often indicates P is connected to T in the center position, but the exact configuration of A and B ports must be verified. Spool Type -60: Critical Center with Bypass Provides the main spool functionality with internal leakage paths to reduce shock. Electrical Connection -BX5-: Sealed, flying lead cable with a 5-pin connector This is different from the standard DIN connector, providing a direct cable connection. Voltage Typically 12 VDC Defined by the coil ordered with the -BX5- connector. Maximum Operating Pressure 350 bar (5,000 psi) Maximum Flow Rate ~ 19 L/min (5 US gpm) Dependent on pressure drop. Fluid Type Mineral-based hydraulic oils, synthetics