Parameter Description / Value Notes Product Line Eaton EEA-PAM Pro-FX Amplifier Module Series Model / Function 581 Specific model within the Pro-FX series, defining its core functionality and I/O. Command Input Type D This letter typically defines the standard input type. "D" often denotes a default or standard analog input configuration (e.g., ±10 VDC). The exact meaning should be verified in the manual. Option Code 32 This suffix defines specific factory options, such as the type of fieldbus communication (e.g., CANopen, J1939, PROFIBUS-DP) or other special features. "32" often indicates a specific fieldbus protocol. General Performance Data Supply Voltage Typically 24 VDC (10 - 30 VDC range) Standard for industrial controls. Output Current Typically up to 3.0 A (PWM) Sufficient to drive most proportional solenoid coils. Command Inputs Typically ±10 VDC, 0-20 mA, 4-20 mA Selectable via software. Communication Interface Defined by -32 suffix (e.g., CANopen) Allows for parameter setting, diagnostics, and closed-loop control via a network. IP Rating IP20 (for cabinet mounting) Designed to be installed inside a protective control cabinet. Ambient Temperature Range 0°C to +55°C (+32°F to +131°F) Standard industrial temperature range. Mounting DIN rail mount (35mm)