Technical Parameters Parameter Value Notes Displacement 180 cm³/rev 10.98 in³/rev Maximum Operating Pressure 420 bar 6,090 psi (continuous) Rated Pressure 350 bar 5,075 psi Peak Pressure 450 bar 6,525 psi (intermittent) Rated Speed 1800 rpm Recommended operating speed Maximum Speed 2200 rpm Absolute maximum Minimum Speed 500 rpm For proper lubrication Volumetric Efficiency ≥ 97% At rated conditions Overall Efficiency ≥ 92% At rated conditions Mechanical Efficiency ≥ 95% At rated conditions DF Control System Characteristics Electro-Hydraulic Proportional Control: Precise electronic displacement control Pressure Compensation: Automatic pressure regulation Flow Control: Proportional flow matching to system demand Load Sensing Compatibility: System pressure demand sensing Power Control: Horsepower limitation capability Multiple Control Modes: Programmable operating modes Physical Specifications Parameter Specification Electrical Control Specifications Parameter Specification Control Signal 0-10V DC or 4-20mA Supply Voltage 24V DC ±10% Current Consumption 2.0A maximum Response Time < 35 ms Hysteresis < 1.5% Linearity < 2% Protection Rating IP66 Shaft Type SAE Standard (19 mm) Mounting SAE 2-bolt type "D" Port Size SAE 1-1/2" (No. 16) Rotation Right-hand (clockwise) Weight Approx. 65 kg (143 lb) Length ~350 mm (13.8 in) Width ~280 mm (11.0 in)