Technical Parameters Parameter Value / Description Notes Nominal Size 16 --- Maximum Operating Pressure (P, A, B ports) 350 bar (5,075 psi) --- Maximum Operating Pressure (T port) 210 bar (3,045 psi) --- Maximum System Flow Up to 120 L/min (32 US gpm) per inlet section Dependent on pump and system design Recommended Maximum Flow per Section 60 - 80 L/min (16 - 21 US gpm) For optimal performance Control Signal Proportional, typically 24V DC PWM Requires a compatible electronic controller Solenoid Resistance ~ 5 - 20 Ohms (varies with model and coil) Check specific datasheet Pressure Compensation Optional (Standard or Load-Independent) A key feature for consistent speed under varying loads Hysteresis < 3% Indicates high repeatability and control accuracy Internal Pilot Supply Standard (from inlet module) --- External Pilot Supply Optional For special operating conditions Port Size Typically SAE 12 (3/4") for work ports May vary