FISHER™ FIELDVUE™ DPC2K

Technical Parameters General Model: FIELDVUE DPC2K Digital Pressure Controller Type: Loop-Powered I/P, I/P with Boost Transducer Microprocessor: Integrated for digital control and communication. Input Signal Standard Analog Input: 4 to 20 mA DC Input Impedance: Typically 10 ohms at 20 mA Output Pressure Standard Ranges: 3 to 15 psig (0.2 to 1.0 bar) 3 to 27 psig (0.2 to 1.9 bar) 6 to 30 psig (0.4 to 2.1 bar) Maximum Supply Pressure: 150 psig (10.3 bar) Performance Accuracy: Typically better than ±0.5% of span. Linearity: Typically better than ±0.5% of span. Hysteresis: Typically less than 0.2% of span. Repeatability: Typically better than 0.2% of span. Sensitivity: Typically less than 0.1% of span. Air Consumption (Static): Typically less than 0.05 SCFM (0.08 Nm³/hr) at zero output flow. Air Supply Required Air Supply: Clean, dry, instrument-quality air, non-lubricated or lubricated. If lubricated, a lubricator must be maintained. Supply Pressure Range: Must be at least 5 psig (0.35 bar) above the required output pressure, up to the maximum of 150 psig (10.3 bar). Environmental Ambient Temperature Range: Operating: -40° to 185°F (-40° to 85°C) Storage: -60° to 185°F (-51° to 85°C) Relative Humidity: 0 to 100% (condensing). Enclosure Rating: NEMA Type 4X (Weatherproof and Corrosion-Resistant) when properly installed. Electrical Loop Power: Powered directly from the 4-20 mA signal loop. No separate power supply is required. HART® Communication: Supports HART protocol (FSK) for digital configuration, calibration, and diagnostics via the same two wires used for the 4-20 mA signal. Physical Mounting: Directly onto actuator mounting holes or via a bracket. Common mounting patterns include Fisher 1052 and 1066 styles. Materials: Housing is typically aluminum with a corrosion-resistant coating. Internal parts are stainless steel and anodized aluminum. Weight: Approximately 2.3 kg (5.0 lbs). Approvals Typically carries FM, FMC, ATEX, IECEx, and CSA approvals for use in hazardous (classified) locations. Specific approval codes depend on the model variant.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
The Fisher™ FIELDVUE™ DPC2K is a compact, loop-powered, microprocessor-based digital pressure controller. It is designed to receive a 4-20 mA analog input signal and precisely translate it into a proportional pneumatic output pressure. This makes it an ideal "I to P" (Current to Pressure) or "I to P with boost" converter for actuating pneumatic valves, dampers, and other final control elements.