Products
Products
home
DT 30806-9 16/26

The ABB DT 30806-9 16/26 is a two-wire, 4-20 mA HART® temperature transmitter designed for universal mounting directly onto a DIN rail. It belongs to ABB's versatile TTH/TTL 300 series Its core function is to accurately measure temperature from various types of resistance thermometers (RTDs like Pt100) or thermocouples (TCs) and convert this measurement into a standardized, linearized 4-20 mA output signal proportional to the measured temperature. The integrated HART communication protocol allows for remote configuration, diagnostics, and parameterization using a HART communicator or compatible control system.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
1. General Data Model: DT 30806-9 16/26 Type: Universal, Loop-Powered, 2-Wire Series: TTH/TTL 300 Mounting: 35 mm DIN Rail (EN 60715) Display: Integrated LCD with backlight (Model "16" indicates display version) Communication: HART Protocol (FOUNDATION Fieldbus compatible), versions 5/6/7 2. Input Specifications Sensor Types: RTD: Pt100, Pt500, Pt1000 (to IEC 60751), Ni100, LG-Ni, Cu10, etc. Thermocouple: Types J, K, T, N, E, R, S, B, L, U, C (to IEC 60584). Ohms/mV: Linear resistance or millivolt input. Sensor Connection: RTD: 2-, 3-, or 4-wire connection (automatic lead resistance compensation for 3/4 wire). Thermocouple: 2-wire connection (internal or external cold junction compensation). 3. Output & Power Analog Output: 4-20 mA DC, two-wire. Load Limit: Maximum loop resistance: Typically 750 Ω at 24 V DC (consult datasheet for full load curve). Power Supply: 12 to 35 V DC (standard loop supply). Operation is dependent on total loop resistance. 4. Performance Reference Accuracy (at 23°C ±5°C): RTD (Pt100): Typically ±0.05% of span or ±0.03°C (whichever is greater). Thermocouple: Typically ±0.1% of span or ±0.5°C (whichever is greater). Note: Accuracy varies by sensor type and range. Refer to official data for exact values. Temperature Coefficient: Typically < ±0.015% of span per 10°C. Update Time: Configurable, typically < 500 ms. Long-Term Stability: Typically < ±0.1% of span per year. 5. Ambient Conditions Ambient Operating Temperature: -40°C to +85°C (-40°F to +185°F). Storage Temperature: -50°C to +100°C. Relative Humidity: 5% to 95%, non-condensing. Electromagnetic Compatibility (EMC): Compliant with IEC/EN 61326. Ingress Protection (IP): IP20 (terminal area - requires installation in an enclosure for protection). Vibration / Shock: Compliant with IEC/EN 60068-2-6 / 60068-2-27. 6. Electrical & Mechanical Terminals: Spring-clamp terminals. Wiring: 0.2 - 2.5 mm² (AWG 24-12). Electrical Isolation: Input to output to ground: Typically 500 V AC. 7. Certifications & Approvals (Typical) The suffix "-9" often indicates a specific set of international approvals. This model is commonly certified for: ATEX / IECEx: For use in Hazardous Areas (e.g., Ex ia IIC T4 Ga / Ex ia IIC T4 Gb). cULus: Listed for Class I, Division 1, Groups A, B, C, D T4; or Class I, Zone 0, AEx/Ex ia IIC T4. FM: Similar approvals for North America. CE Marking: Compliant with EU directives. SIL: Capable of supporting Safety Integrity Level (SIL 2) applications in accordance with IEC 61508.