AX205-30-11-80 220V 1SFL501074R8011

The ABB AX205‑30‑11‑80 is a three‑pole AC magnetic contactor designed for robust industrial and commercial use in three‑phase power switching and motor control applications. It features three main normally open contacts and built‑in auxiliary contacts (1 NO + 1 NC) for control and signaling. The device is intended for control circuits with a coil voltage around 220–230 V AC (50 Hz) or 230–240 V AC (60 Hz) and can handle heavy switching loads up to systems rated around 690 V AC or above, making it suitable for motor starters, power distribution switching, and general industrial control panels.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Key Technical Parameters General & Electrical Ratings Product / Model: ABB AX205‑30‑11‑80 Contactor Part Number: 1SFL501074R8011 Type: Three‑pole AC magnetic contactor Main Contacts: 3 normally open (3 NO) Auxiliary Contacts: 1 normally open + 1 normally closed (1 NO + 1 NC) Control/Coil Voltage: 220–230 V AC (50 Hz) or 230–240 V AC (60 Hz) Rated Insulation Voltage (Ui): ~690 V AC Rated Operational Voltage (Main Circuit): ~1000 V AC capacity (design) Current & Power Capabilities Conventional Free‑Air Thermal Current (Ith): ~250 A at 40 °C free air Rated Operational Current AC‑1 (Ie): ~275 A at 690 V AC (40 °C) ~250 A at 690 V AC (55 °C) ~180 A at 690 V AC (70 °C) Rated Operational Current AC‑3 (Ie): ~205 A at 220–240 V AC (55 °C) ~205 A at 380–400 V AC (55 °C) ~185 A at 440 V AC (55 °C) ~170 A at 500–690 V AC (55 °C) Rated Operational Power (AC‑3): ~59 kW at 220–240 V AC ~110 kW at 380–400 V AC ~90 kW at 440 V AC ~110 kW at 500 V AC ~132 kW at 690 V AC Switching Capacity & Durability Rated Making Capacity (AC‑3): ~10 × Ie Rated Breaking Capacity (AC‑3): ~8 × Ie Maximum Electrical Switching Frequency: ~300 cycles/hour Maximum Mechanical Switching Frequency: ~3600 cycles/hour Mechanical Durability: ~5 million operations Short‑Time Withstand Currents Short‑time withstand (cold state): ~1200 A for 10 s ~600 A for 1 min ~280 A for 15 min ~1800 A for 1 s ~800 A for 30 s Physical & Environmental Mounting & Connections: Front terminal bars for main circuit; screw terminals for control Degree of Protection: IP20 to terminals Ambient Operating Temperature: –40 °C to +70 °C (varies with installation and coil/load) Typical Dimensions: ~111.5 mm (W) × ~162.3 mm (D) × ~196 mm (H) Weight: ~3.2 kg Typical Applications Motor starters and reversing circuits for three‑phase motors Switching and control of three‑phase power circuits in industrial panels Isolation and by‑pass switching in automation systems General power distribution and control functions