PR122/D-M

The ABB PR122/D-M is a digital trip unit designed for ABB Emax and Emax2 series low-voltage air circuit breakers. The “D-M” version provides digital protection with advanced metering (M) functions. It offers comprehensive current and power measurements, event indication, and enhanced monitoring capabilities, making it ideal for applications requiring both protection and accurate energy monitoring. The unit features a clear LCD interface for settings, real-time data display, and diagnostics. When combined with optional communication modules, the PR122/D-M supports remote monitoring and integration into industrial automation or energy management systems.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Specifications Protection Functions (Protection levels depend on breaker configuration) Long-time protection (L) Adjustable overload protection with programmable pickup and delay. Short-time protection (S) Adjustable pickup and delay with I²t ON/OFF. Instantaneous protection (I) Adjustable magnetic trip for short-circuit protection. Neutral protection (N) (when neutral CT or module is installed) Note: PR122/D-M supports standard protection suite of PR122/D series; ground-fault “G” protection requires the respective version (not included in D-M). Metering & Measurement (M – Metering Function) Phase currents Neutral current (with module) Ground current indication Voltage values (with voltage module) Power & energy (kW, kWh, kVA, kVAR) Frequency Power factor Thermal capacity Trip history & events Display & Operation Large multifunction LCD display Local pushbuttons for settings and navigation LED indicators for status and alarms Adjustable Settings L – Long-time pickup & delay S – Short-time pickup & delay, I²t enabled/disabled I – Instantaneous pickup setting N – Neutral protection (optional) Supported Current Ratings Compatible with Emax/Emax2 breakers rated: 160 A – 6300 A, depending on frame size and CT rating. Accuracy Current measurement: typically ±1% Voltage & power measurement (with module): high accuracy per IEC standards Tripping characteristics compliant with IEC 60947-2 Communication (Optional) Supports ABB communication modules such as: Modbus Profibus DeviceNet Ethernet gateways (via expansion) Enables remote settings, monitoring, and event logs. Power Supply Self-powered via CTs Optional auxiliary power depending on configuration Compliance IEC 60947-1 IEC 60947-2 CE and international approvals (breaker-dependent)