Products
Products
home
BSM90C-375CAX

AF460‑30‑11 is a 3‑pole AC contactor from ABB’s AF series, intended for motor control, power‑circuit switching, motor starters, isolation, bypass and distribution applications.It features 3 main contacts (normally open — 3NO) and includes one auxiliary contact set (1 NO + 1 NC) for control or signaling circuits.The coil control voltage supports a wide range (e.g. 100–250 V AC or DC, depending on version), allowing reliable operation under varying control‑voltage conditions and supporting energy‑efficient panel design.Its robust design with built‑in surge suppression and the “AF technology” ensures stable operation even under unstable networks. The block‑type design allows expansion with add‑on auxiliary contact blocks and other accessories.It is suitable for heavy‑duty industrial use: switching power circuits and controlling three‑phase motors, up to high voltage/current ratings.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Specifications Parameter Value / Description Model / Part Number AF460‑30‑11 (1SFL597001R7011) Poles (Main Contacts) 3 poles, 3 NO (normally open) Auxiliary Contacts 1 NO + 1 NC Coil (Control) Voltage (Uc) 100–250 V AC 50/60 Hz or 100–250 V DC (depending coil version) Rated Insulation / Maximum Rated Voltage Up to 1000 V IEC (600 V UL) Conventional Free‑air Thermal Current (Ith) 700 A (open contactor, ambient 40 °C) Rated Operational Current AC‑1 (Ie) 700 A @ 1000 V, 40 °C 600 A @ 1000 V / 55 °C 600 A @ 1000 V / 60 °C 480 A @ 1000 V / 70 °C (equivalently at 690 V: 700 A → 600 A → 480 A depending on temperature) Rated Operational Current AC‑3 (Ie) 460 A @ 415–500 V (55 °C) 400 A @ 690 V (55 °C) 200 A @ 1000 V (55 °C) 460 A @ 380/400 V or 220–240 V (55 °C) Rated Operational Power (AC‑3, Pe) 250 kW @ 415–440 V 315 kW @ 500 V 355 kW @ 690 V 280 kW @ 1000 V 250 kW @ 380/400 V 132 kW @ 220–240 V Making / Breaking Capacity (AC‑3) Making: 10 × Ie Breaking: 8 × Ie Short‑time Withstand Current (Icw) (cold start, free air, 40 °C) 1 s → 4600 A 10 s → 4400 A 30 s → 3100 A 1 min → 2500 A Connection Type (Main Circuit) Bar-type main contacts (supports rigid copper or aluminium cables/bars) Auxiliary & Coil Terminal Wiring Capacity Aux circuit: flexible cables with ferrules 2×0.75–2.5 mm², or solid/stranded 1–4 mm² Main circuit: rigid Cu 240 mm² or Al 2×240 mm² bar Ambient Operating Temperature With thermal overload relay: –25 °C … +50 °C Without overload relay: –40 °C … +70 °C Storage: –40 °C … +70 °C Maximum Operating Altitude Up to 3000 m Certifications / Use Cases UL/CSA general‑use rating: 650 A @ 600 V AC; suitable for motor starters, power switching, bypass/distribution, heavy‑duty switching