The ABB OFAFC000GG80 is a high-current, electronic overload relay from ABB's OFAF series, a core component of the System Pro M compact® motor management line. It is engineered to provide advanced thermal and electrical protection for medium-sized to large three-phase AC induction motors. The suffix "GG80" indicates a model with a maximum adjustable current setting of 80 Amperes, making it suitable for protecting motors with significantly higher power ratings than its lower-current counterparts.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List

Parameters Category Parameter Specification for OFAFC000GG80 General Type Electronic, Adjustable, 3-Phase Overload Relay Series OFAF Series (System Pro M compact®) Trip Class Class 10 (IEC/EN 60947-4-1) Maximum Setting Current (Iₓ) 80 A (Adjustable range, e.g., 22 - 80 A) Protection Functions Overload Protection Electronic I²t thermal model with ambient temp. compensation. Phase Loss Sensitivity Yes. Fast tripping on loss of phase (within seconds at FLC). Phase Unbalance Protection Yes. Protection against excessive current asymmetry. Locked Rotor Protection Inherent via fast trip on high starting current. Settings & Controls Current Setting Rotary dial, adjustable within specified range. Reset Mode Manual (push-button) or Automatic (selectable via slide switch). Test Function Integrated TEST button. Trip Indication Mechanical flag (red) and/or LED. Phase Loss Indication Separate LED indicator. Electrical Characteristics Rated Operational Voltage (Uₑ) Up to 690 V AC, 50/60 Hz (for main circuit isolation). Auxiliary Contact Voltage Typically ≤ 600 V AC/DC. Power Supply Self-powered via internal current sensors; no external supply needed. Auxiliary Contacts Trip Contact (95-96) 1 NC (Normally Closed) – Breaks contactor coil circuit. Alarm/Signal Contact (97-98) 1 NO (Normally Open) – Makes on trip for remote indication. Contact Rating AC-15: 6 A at 230 V; DC-13: 0.3 A at 230 V. Current Sensors & Burden Sensor Type Integrated Current Transformers (CTs). Continuous Withstand 1.2 x Iₓ (Max Setting) continuously. Mounting & Connection Mounting 35 mm top-hat DIN rail (EN 60715). Main Terminals (1/L1-3/L2-5/L3, 2/T1-4/T2-6/T3) Screw clamp. Accepts 16 - 50 mm² cable (typical for 80A). Auxiliary Terminals (A1/A2, 95-96, 97-98) Screw clamp. Accepts 0.5 - 2.5 mm² cable. Environmental Operating Temperature -25°C to +60°C (calibrated at +40°C) Storage Temperature -40°C to +70°C Altitude Up to 2000 m without derating Pollution Degree PD 2 Protection Degree IP20 Physical Dimensions (W×H×D) Approx. 70 x 130 x 110 mm (Varies; larger than lower-current models) Weight Approx. 0.5 - 0.7 kg Motor Reference (400V, 3~) Approx. Motor Power ~45 kW (60 HP) (Based on 80A FLC at 400V, cos φ ~0.85) Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14