MS116-1.6

The ABB MS116-1.6 is a bimetallic, direct-heated, fixed-setting thermal overload relay designed to protect three-phase AC motors from damage caused by sustained overloads and phase loss (under certain conditions). It is a robust, traditional electromechanical protective device. The "1.6" indicates its maximum adjustable current setting range, which is 1.6 Amperes. It is installed in series with the motor power circuit and operates by sensing the heat generated by the motor current passing through its internal bimetal strips. When an overload condition persists long enough to cause excessive heating, the relay trips, opening its normally closed (NC) auxiliary contact to interrupt the control circuit and de-energize the motor contactor.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Specifications / Parameters Parameter Specification Manufacturer Type Code MS116-1.6 Brand / Series ABB MS (Motor Starter) Series - Thermal Overload Relay (TOL) Device Type Thermal Overload Relay (Direct Heating, Bi-metallic) Protection Functions • Sustained Overload Protection (Inverse Time Characteristic) • Single-Phase (Phase Loss) Protection (through inherent design imbalance) • Motor Locked Rotor Protection Rated Operational Current (Ie) The device's operational range. For MS116-1.6, the setting range is 1.0 to 1.6 A. Setting Current (Ir) Adjustable via a dial within the specified range (1.0 - 1.6 A). This should be set to the motor's full-load current (FLC) as stated on its nameplate. Ambient Temperature Compensation Yes (Built-in). The bimetal system compensates for variations in the surrounding air temperature, ensuring accurate protection. Trip Class Typically Class 10 (Standard trip time at 7.2 x Ir is about 10 seconds). This is suitable for standard motor starting. Control Contacts • 1 Normally Closed (NC) Contact (95-96): Used to break the contactor coil circuit upon trip. • 1 Normally Open (NO) Contact (97-98): Can be used for a trip indication/alarm circuit. Contact Ratings Typically: • NC (95-96): 6A / 230V AC (AC-15) • NO (97-98): 6A / 230V AC (AC-15) Mounting Direct Snap-on mounting onto compatible ABB contactors (e.g., A-series) or onto a separate mounting base. Reset Mode Manual reset (push-button) after a trip and cool-down period. Automatic reset versions are available as separate variants. Standards Compliance IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 14. Application Protection of small three-phase motors with full-load currents between 1.0 and 1.6 Amperes.