CC-U/STDR 1SVR040010R0000

The ABB CC-U/STDR 1SVR040010R0000 is a universal resistance monitoring relay from the ABB CR-U series. This specialized electronic relay is designed to monitor the resistance value of an external circuit or sensor by applying a small, safe DC measuring current. It functions as a precision ohmmeter with adjustable setpoints. When the measured resistance exceeds or falls below the user-defined thresholds, the relay activates its output contacts. It is commonly used for continuous monitoring of continuity, insulation resistance (to a limited extent), or the value of resistive sensors, making it ideal for applications like liquid level detection with conductivity probes, moisture detection, ground integrity monitoring, and supervision of heating elements.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Technical Specifications / Parameters Parameter Specification Manufacturer Order Code 1SVR040010R0000 Catalogue Type CC-U/STDR Brand / Series ABB CR-U Series (Universal Monitoring Relays) Device Type Universal Resistance Monitoring Relay Monitoring Function Monitors the ohmic resistance (R) of a two-wire loop connected to its input terminals. Measurement Principle Applies a constant DC measuring current and measures the resulting voltage drop to calculate resistance. Resistance Measurement Range Typically from a few ohms (Ω) up to several megaohms (MΩ). Specific ranges (e.g., 0-10kΩ, 0-1MΩ) are selectable via front switches or DIPs. 必须核实具体型号范围。 Number of Setpoints Two independent adjustable setpoints (High and Low), typically via potentiometers. Setpoint Logic Configurable to trigger when resistance is above a high limit, below a low limit, or inside/outside a window defined by the two limits. Output Relay 1 Changeover (CO) Contact (SPDT: 1 NO + 1 NC) • Contact Rating: Typically 6A / 250V AC (resistive load). Power Supply (Auxiliary) 24...240V AC/DC (wide-range, for relay electronics). Measuring Voltage/Current Uses a low, safe DC voltage/current for measurement to avoid influencing the monitored system (e.g., < 10V DC). Status Indication LEDs for Power, Alarm/Trip, and sometimes Measurement Active. Hysteresis Adjustable or fixed, to prevent output chatter near the setpoint. Mounting DIN Rail Mounting (35mm). Module Width 22.5 mm (1 module width). Operating Temperature -25°C to +55°C. Front Protection Degree IP40. Standards & Approvals IEC/EN 60255, UL 508, CSA C22.2 No. 14, CE, cULus. Typical Applications • Conductivity-based liquid level detection in tanks (probe resistance changes when immersed). • Moisture or humidity detection (with resistive humidity sensors). • Monitoring of heating elements for open circuit (infinite resistance) or degradation. • Ground electrode or bonding strap continuity checking. • Simple insulation monitoring of low-voltage circuits (e.g., detecting coolant leakage into a motor winding).