Products
Products
home
UD1BG3-045N-1KC-2TA-N

The Yokogawa UD1BG3-045N-1KC-2TA-N is a complete, high-performance laser displacement sensor system from Yokogawa's UD Series. It is designed for non-contact, precise distance and position measurement in industrial automation applications, offering an excellent balance of performance, range, and value.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
(Technical Parameters)
Parameter Category Specification Details
Model UD1BG3-045N-1KC-2TA-N (Complete System)
Measurement Principle Triangular Reflection Method
Laser Type Red semiconductor laser (Visible beam)
Laser Wavelength 655 nm (Red)
Measurement Range 45 ±15 mm (Total range of 30mm, from 30mm to 60mm from the sensor head)
Standing Distance 45 mm (Recommended working distance to target)
Spot Diameter Approximately 0.4 × 0.8 mm (at a 45mm standing distance)
Linear Output Range ±15 mm (around the 45mm standing distance)
Repeatability 10 µm
Linearity ±0.1% of F.S. (Full Scale = 30mm range)
Light-Receiving Element PSD (Position Sensitive Detector)
Sampling Rate 2 kHz
Outputs Analog Output: 4-20 mA
Switch Output: 2-point NPN open collector output
Power Supply 12 to 24 VDC (±10%), ripple P-P: 10% max.
Current Consumption 80 mA max. (excluding analog output current)
Connection Method -2TA Option: Pre-wired cable (2m for head-to-amplifier, 2m for amplifier power/control)
Amplifier Unit -1KC: Separate, compact amplifier
Housing Material PPS (Sensor Head), Aluminum Die-cast (Amplifier Unit)
Ingress Protection (IP Rating) IP67 (Sensor Head) / IP66 (Amplifier Unit)
Ambient Operating Temperature -10 to +55 °C (Sensor Head & Amplifier, with no freezing or condensation)
Ambient Operating Humidity 35 to 85% RH
Vibration Resistance 10 to 55 Hz, Double amplitude 1.5 mm, X, Y, Z directions for 2 hours each
Shock Resistance 500 m/s² (approx. 50G), X, Y, Z directions 3 times each
Weight Sensor Head: Approx. 70 g / Amplifier: Approx. 200 g