The Yokogawa ANB10D-415/CU2N is an Intrinsic Safety Barrier, a critical component for ensuring safety in hazardous (potentially explosive) areas. It is designed for DIN rail mounting inside the safe area control panel.
Its primary function is to limit the energy (voltage and current) that can be transmitted from the safe-area control system (e.g., DCS, PLC) into a hazardous area where instruments like transmitters, solenoid valves, or switches are located. This prevents the electrical signals from providing a source of ignition for flammable gases, vapors, or dusts, thus ensuring intrinsic safety (IS).

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Specifications
Parameter Category Specification for ANB10D-415/CU2N
Model Number ANB10D-415/CU2N
Product Type Intrinsic Safety Barrier (Dual Channel)
Mounting Standard 35mm DIN rail mounting.
Number of Channels 2 (Dual Channel). The D in the model number often denotes a dual-channel barrier.
Approved Safety Standard FM / cULus (U.S. and Canada) for Class I, Division 2 hazardous areas. The CU2N suffix strongly indicates this certification. It may also comply with IECEx and ATEX standards.
Hazardous Area Rating The connected field device is approved for use in:**
• Class I, Division 1, Groups A, B, C, D
• Class II, Division 1, Groups E, F, G
• Class III, Division 1
[Note: The barrier itself is mounted in the safe area]
Safe Area Parameters • Supply Voltage (Ui): 250V AC/DC max (from the control system side)
• Supply Current (Ii): Typically limited by the barrier's design.
Hazardous Area Parameters • Maximum Output Voltage (Uo): ~15 V DC (estimated based on 415 code)
• Maximum Output Current (Io): ~150 mA (estimated based on 415 code)
• Maximum Output Power (Po): ~1.5 W (estimated based on 415 code)
• Maximum External Capacitance (Co): < 1.0 µF
• Maximum External Inductance (Lo): < 10 mH
These parameters define the maximum allowed capacitance and inductance for the field device and its wiring.
Field Device Compatibility Designed to protect 2-wire 4-20mA transmitters (e.g., pressure, temperature, flow) or digital input (DI) devices like mechanical switches, proximity switches, or solenoid valves.
Construction • Type: Passive Barrier. Uses a combination of current-limiting resistors and voltage-limiting Zener diodes to provide protection. Requires a dedicated, isolated earth ground for the grounding bar for proper operation.
• Terminals: Screw terminals for easy wiring.
Operating Temperature -40°C to +85°C (-40°F to +185°F)
Certifications cULus Listed (UL 913), likely also ATEX and IECEx certified. The CE mark is also present.
Key Features and Applications
Hazardous Area Protection: The core function is to prevent ignition in hazardous areas by limiting energy, enabling the safe use of electrical instruments.

Dual-Channel Design: Saves space in the control panel by providing protection for two field devices with a single module.

Passive Design: Highly reliable as it contains no active electronic components that can fail.

System Compatibility: Works seamlessly with Yokogawa control systems (like CENTUM VP) and other manufacturers' PLCs/DCS.

Global Certifications: Meets international safety standards, allowing for use in projects worldwide.

Primary Applications:

Used in Oil & Gas platforms, refineries, and pipelines.

Chemical and Pharmaceutical plants.

Paint and Coating manufacturing facilities.

Grain Silos and any other location where combustible materials are present.