The Yokogawa ANB10D-425 is a single-point, insertion-type thermal mass flow meter designed for monitoring compressed air and other gas flows in pipes. It is a fundamental model in Yokogawa's ANB Series, providing a cost-effective solution for applications where high accuracy at very low flows or a multi-point average is not the primary requirement.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Specifications & Parameters
Category Specification Details
Model Code ANB10D-425
Product Line Yokogawa ANB Series Insertion Thermal Mass Flow Meter
Type Insertion-type, Single-Point Thermal Mass Flow Sensor
Principle Thermal Dispersion (Constant Temperature Difference)
Number of Sensors 2 sensors (1 velocity, 1 temperature) on a single point.
Primary Application Compressed Air and Gas Flow Measurement
Output Signal This is a sensor only. It requires a separate transmitter (e.g., Yokogawa YTA Series) to provide a 4-20 mA output, communication, and power.
Process Connection Typically 1/2" NPT male thread. (Must be confirmed with installation manual).
Flow Tube Length 425 mm (This is the insertion length, determining the suitable pipe diameter).
Accuracy Varies with the paired transmitter, but typical system accuracy is around ±2% of Reading ±0.05% of F.S.
Velocity Range Low minimum velocity, typically from 0.3 NM/s up to 50 NM/s.
Pipe Size Range The 425 mm length is suitable for a specific range of pipe diameters (e.g., commonly for 4-inch / 100 mm pipes). The exact suitable pipe size must be confirmed from selection charts.
Fluid Temperature Standard: -40°C to 200°C (-40°F to 392°F)
Ambient Temperature -40°C to 85°C (-40°F to 185°F)
Sensor Material Stainless Steel
Wetted Materials Stainless Steel