RLY3-OSSD200

The SICK RLY3-OSSD200 is a compact and versatile safety relay module designed to process signals from safety devices with OSSDs (Output Signal Switching Devices). It acts as a critical interface between safety sensors (e.g., light curtains, safety switches, laser scanners) and machinery controls, ensuring safe shutdown of equipment when a hazard is detected. This module is engineered to meet rigorous safety standards and is ideal for applications requiring high reliability in industrial automation.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Key Features
Dual OSSD Input Channels:

Accepts two-channel OSSD inputs (typically PNP signals) from safety devices, providing cross-fault monitoring for enhanced safety integrity.

Detects faults such as short circuits, wire breaks, and device failures.

Safety Relay Outputs:

Provides 2 normally open (NO) safety relay contacts for controlling machinery power circuits.

Enforces safe torque off (STO) or emergency stop functionality by interrupting power to hazardous actuators.

Compact DIN Rail Design:

Space-saving form factor for easy integration into control panels.

DIN rail mountable (standard 35 mm rail).

Diagnostic Indicators:

LED status indicators for power (PWR), input status (IN1, IN2), and output status (OUT), facilitating quick troubleshooting and maintenance.

Compliance with Safety Standards:

Meets ISO 13849-1 PL e (Performance Level e) and IEC 61508 SIL 3 (Safety Integrity Level 3), ensuring compliance with global machinery safety directives.

Wide Operating Voltage Range:

Supports 24 V DC supply voltage (with a typical range of 20.4 V to 28.8 V DC), suitable for industrial environments.

Flexible Configuration:

Allows manual or automatic reset options based on application requirements.

Technical Specifications
Parameter Specification
Product Type Safety Relay Module
Input Channels 2 (OSSD, PNP type)
Output Type 2 NO safety relay contacts (3A @ 250 V AC)
Supply Voltage 24 V DC (±20%)
Safety Level ISO 13849-1 PL e, IEC 61508 SIL 3
Mounting DIN rail (35 mm)
Connection Screw terminals
Operating Temperature -25 °C to +55 °C
Protection Rating IP20 (for enclosure mounting)
Reset Mode Manual or automatic (selectable)
Typical Applications
Machine Guarding: Interfacing with safety light curtains (e.g., SICK deTec4) to halt machinery when access is detected.

Emergency Stop Systems: Processing signals from emergency stop buttons or rope pull switches.

Robotics Safety: Enabling safe operation of collaborative robots by monitoring safety sensor inputs.

Presses and Injection Molding Machines: Ensuring safe shutdown during maintenance or operator intervention.

Automated Production Lines: Providing safety control for conveyor systems and automated machinery.