Products
Products
home
EGCP-2 DIGITAL CONTROL 8406-121

The Woodward EGCP-2 (8406-121) is a digital generator control panel designed for standby and prime power applications, providing comprehensive power management and protection.

open

close

TEL:400-887-3214
Mail:jilineasyyi@outlook.com
Q Q:615739355
Parameters
Request a Quote
Return to List
Sequence Overview
Sequence Type: Digitally Optimized Fast Gradient Echo (GRE) with Dynamic Contrast Enhancement (DCE) Capability

Field Strength: 1.5T / 3T (Optimized for High-Speed Imaging)

Primary Applications:

Dynamic Contrast-Enhanced (DCE) MRI

Perfusion Imaging (Brain, Body Tumors)

Time-Resolved Angiography

Vendor Classification: Proprietary EGCP Protocol (Enhanced Gradient Control Platform)

Core Technical Parameters
1. Sequence Encoding (8406-121)
8406: Ultra-Fast k-Space Sampling (840 Lines/TR, 6 Echoes)

121: Dynamic Temporal Resolution (121 ms/frame)

2. Acquisition Parameters
TR (Repetition Time): 3.5-5.0 ms (Adjustable in 0.1 ms Steps)

TE (Echo Time): 1.2-2.0 ms (Shortest Possible for T1-Weighting)

Flip Angle: **10°-25° (User-Adjustable for T1/T2* Weighting)**

Temporal Resolution: 121-250 ms (Time-Resolved Mode)

Spatial Resolution:

In-Plane: 1.0 × 1.0 mm (Standard) → 0.6 × 0.6 mm (High-Res)

Slice Thickness: 3-5 mm (2D) / 1-2 mm (3D Volumetric)

3. Dynamic Contrast Features
DCE-MRI Mode:

T1 Mapping Pre-Contrast (Variable Flip Angle: 2°, 5°, 10°)

Real-Time AI-Based Kinetic Modeling (Tofts/Extended Tofts)

Time-Resolved MRA (TR-MRA):

Sub-Second Frame Rate (0.8-1.2 sec/volume)

Keyhole Reconstruction (50% k-Space Update)

Advanced Features
1. Acceleration & Efficiency
Compressed Sensing: 6× Acceleration (15 sec Full Liver DCE)

Parallel Imaging (ARC): Up to 4× (Combined with CS)

View Sharing (TWIST/CART): For Ultra-High Temporal Resolution

2. Motion & Artifact Control
Respiratory Triggering (Body): Adaptive Navigator Echo

Cardiac Synchronization (Cine DCE): ECG-Gated Acquisition

B0 Drift Correction: Real-Time Field Monitoring

3. Smart Post-Processing
Automated Perfusion Maps:

Ktrans, Ve, Kep (DCE Oncology Analysis)

rCBV, rCBF (Brain Perfusion)

Vessel Tracking MRA: AI-Based Vessel Segmentation

4D Visualization: Tumor Enhancement Curves (DICOM Export)

Clinical Protocols
1. DCE-MRI (Oncology)
Recommended Settings:

TR/TE = 4.0/1.5 ms, Flip Angle = 15°

Temporal Res = 5 sec (20 Phases, 0.1 mmol/kg Gd)

Scan Time: 2 min (Liver), 1.5 min (Breast)

Key Applications:

HCC/Liver Metastasis (LI-RADS Classification)

Breast Cancer (BI-RADS Enhancement Kinetics)

2. Time-Resolved MRA (Neuro/Body)
Recommended Settings:

TR/TE = 3.8/1.3 ms, Flip Angle = 18°

0.8 sec/volume (40 Phases, 0.2 mmol/kg Gd)

Scan Time: 30 sec (Circle of Willis)

Key Applications:

AVM Shunt Evaluation

PE/DVT (Pulmonary Embolism Imaging)

3. Cardiac Perfusion (Stress-Rest)
Recommended Settings:

TR/TE = 3.5/1.2 ms, Flip Angle = 12°

ECG-Gated, 1-2 sec/heart phase

Scan Time: 30 sec/stress phase

Key Applications:

Ischemia Detection (CAD)

Myocardial Viability

Performance Metrics
Temporal Resolution: 121 ms (High-Speed Mode)

Spatial Resolution: 0.6 mm (High-Res 3D)

SNR (Liver DCE): ≥35 dB (3T, NEX=1)

Artifact Suppression: <5% Ghosting (Motion-Compensated)

Technologist Guide
1. Protocol Optimization
For 3T Scans:

Reduce flip angle by 5° (SAR Management)

Increase bandwidth to ±62 kHz (Reduce Susceptibility)

Pediatric Imaging:

Use 50% dose Gd + 2× NEX

2. Troubleshooting
Incomplete Enhancement:

Check injection timing (Bolus Tracking Recommended)

Increase flip angle to 20° (T1 Weighting Boost)

Aliasing Artifacts:

Enable oversampling (20% Phase FOV)

3. Contraindications
Non-Compatible With:

Non-MRI conditional pacemakers

Severe renal impairment (Gd caution)