Products
Products
home
6.0P 47059

The Control Unit 6.0P (Order No. 47059) is a professional-grade control component from Schneider Electric's industrial automation portfolio. This unit is designed for precise system control and monitoring applications, typically used in conjunction with Schneider's motor starters or protection devices.

open

close

TEL:400-887-3214
Mail:jilineasyyi@outlook.com
Q Q:615739355
Parameters
Request a Quote
Return to List
Schneider Electric Control Unit 6.0P - Technical Specifications
General Parameters
Model Designation: Control Unit 6.0P

Manufacturer Part Number: 47059

Product Series: TeSys D / LR9 / LR2 (verify specific compatibility)

Type: Thermal-Magnetic Trip Unit

Mounting: DIN Rail (35mm)

Weight: Approximately 150g

Electrical Characteristics
Rated Current (Ie): 6A (adjustable range typically 4.5-6A)

Rated Voltage:

690V AC (50/60Hz)

250V DC

Breaking Capacity:

100kA at 415V AC (IEC/EN 60947-4-1)

10kA at 250V DC

Trip Class: Class 10 (motor protection)

Protection Features
Overload Protection: Adjustable via rotary dial

Short-Circuit Protection: Magnetic trip (fixed or adjustable)

Phase Loss Protection: Integrated

Ambient Compensation: Automatic

Mechanical Specifications
Terminal Capacity:

1-6mm² (AWG 18-10) for line/load connections

0.5-2.5mm² (AWG 24-14) for control wiring

Torque Specifications: 1.2Nm (10.6 lb-in)

Mechanical Life: 10,000 operations minimum

Environmental Ratings
Operating Temperature: -20°C to +60°C (-4°F to +140°F)

Storage Temperature: -40°C to +85°C (-40°F to +185°F)

Relative Humidity: 5% to 95% (non-condensing)

Altitude: Up to 2000m (6562 ft) without derating

Standards & Certifications
Safety Standards: IEC/EN 60947-4-1

UL Certification: File E103948

CE Marking: Compliant

RoHS: Directive 2011/65/EU compliant

Ordering Information
Base Unit: 47059 (Control Unit 6.0P)

Accessories:

Auxiliary contacts (e.g., LADN22)

Shunt releases (e.g., LA7DN20)

DIN rail end stops

Compatibility
Designed for use with:

TeSys D contactors (e.g., LC1D series)

LR9/LR2 thermal overload relays

Other Schneider motor starters (verify specific models)

Physical Dimensions
Height: 80mm (3.15in)

Width: 45mm (1.77in)

Depth: 73mm (2.87in)

For complete installation instructions and application guidelines, refer to:

TeSys D Control Components Catalog (DOCA0035EN)

IEC 60947-4-1 Standard Compliance Document