ATV630D90N4

Variable Speed Drive, Altivar Process ATV600, ATV630, 90kW, 125hp, 380 to 480V, IP21, UL type 1
ATV630D90N4

open

close

TEL:400-887-3214
Mail:jilineasyyi@outlook.com
Q Q:615739355
Parameters
Request a Quote
Return to List
Main
Range of Product
Altivar Process ATV600
Product Specific Application
Process and utilities
Product or Component Type
Variable speed drive
Variant
Standard version
Device short name
ATV630
Mounting Mode
Wall mount
Communication Port Protocol
Ethernet
Modbus serial
Modbus TCP
[Us] rated supply voltage
380...480 V - 15...10 %
[Us] rated supply voltage
380...480 V
Relative symmetric mains voltage tolerance
10 %
Relative symmetric network frequency tolerance
5 %
nominal output current
173.0 A
IP degree of protection
IP21
Product destination
Asynchronous motors
Synchronous motors
EMC filter
Integrated 492.1 ft (150 m) IEC 61800-3 category C3
IP degree of protection
IP21IEC 61800-5-1
IP21IEC 60529
Degree of protection
UL type 1 UL 508C
type of cooling
Forced convection
Supply frequency
50...60 Hz - 5...5 %
Motor power kW
90 kW normal duty)
75 kW heavy duty)
Maximum Horse Power Rating
125 hp normal duty
100 hp heavy duty
Line current
156.2 A 380 V normal duty)
135.8 A 480 V normal duty)
134.3 A 380 V heavy duty)
118.1 A 480 V heavy duty)
Continuous output current
173 A 2.5 kHz normal duty
145 A 2.5 kHz heavy duty
Speed drive output frequency
0.1…500 Hz
Safety function
STO (safe torque off) SIL 3
Option card
Slot A communication module, Profibus DP V1
Slot A communication module, PROFINET
Slot A communication module, DeviceNet
Slot A communication module, Modbus TCP/EtherNet/IP
Slot A communication module, CANopen daisy chain RJ45
Slot A communication module, CANopen SUB-D 9
Slot A communication module, CANopen screw terminals
Slot A/slot B digital and analog I/O extension module
Slot A/slot B output relay extension module
Slot A communication module, Ethernet IP/Modbus TCP/MD-Link
communication module, BACnet MS/TP
communication module, Ethernet Powerlink
Complementary
Discrete input number
8
Discrete input type
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V)
Discrete input logic
16 preset speeds
Discrete output number
0
Discrete output type
Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number
3
Analogue input type
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits
AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Analogue output number
2
Analogue output type
Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 10 bits
Software-configurable current DQ-, DQ+ 30 V DC
Software-configurable current DQ-, DQ+ 100 mA
Relay output number
3
Relay output type
Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles
Maximum switching current
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current
Relay output R1, R2, R3 5 mA 24 V DC
Phase
3 phase
Physical interface
Ethernet
2-wire RS 485
Method of access
Slave Modbus TCP
Transmission Rate
10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frame
RTU
Output voltage
<= power supply voltage
Permissible temporary current boost
1.1 x In 60 s normal duty)
1.5 x In 60 s heavy duty)
Data format
8 bits, configurable odd, even or no parity
Type of polarization
No impedance
Frequency resolution
Display unit 0.1 Hz
Analog input 0.012/50 Hz
Electrical connection
Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 120 mm² AWG 4/0...250 kcmil
Motor screw terminal 120 mm² 250 kcmil
Connector type
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
RJ45 on the remote graphic terminal)Modbus serial
Exchange mode
Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses
1…247 Modbus serial
Supply
External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection
Local signalling
3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Input compatibility
DI1...DI6 discrete input level 1 PLC IEC 61131-2
DI5, DI6 discrete input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2
Discrete input logic
Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V
Sampling duration
2 ms +/- 0.5 ms DI1...DI4) - discrete input
5 ms +/- 1 ms DI5, DI6) - discrete input
5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
10 ms +/- 1 ms AO1) - analog output
Accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity error
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AO1, AO2 +/- 0.2 % analog output
Refresh time
Relay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolation
Between power and control terminals
Discrete and process manufacturing
Building - HVAC compressor centrifugal
Food and beverage processing other application
Mining mineral and metal fan
Mining mineral and metal pump
Oil and gas fan
Water and waste water other application
Building - HVAC screw compressor
Food and beverage processing pump
Food and beverage processing fan
Food and beverage processing atomization
Oil and gas electro submersible pump (ESP)
Oil and gas water injection pump
Oil and gas jet fuel pump
Oil and gas compressor for refinery
Water and waste water centrifuge pump
Water and waste water positive displacement pump
Water and waste water electro submersible pump (ESP)
Water and waste water screw pump
Water and waste water lobe compressor
Water and waste water screw compressor
Water and waste water compressor centrifugal
Water and waste water fan
Water and waste water conveyor
Water and waste water mixer
Power range
55…100 kW 380…440 V 3 phase
55…100 kW 480…500 V 3 phase
Enclosure mounting
Wall mounted
4 quadrant operation possible
False
Asynchronous motor control profile
Constant torque standard
Variable torque standard
Optimized torque mode
Synchronous motor control profile
Permanent magnet motor
Synchronous reluctance motor
Maximum output frequency
500 kHz
Acceleration and deceleration ramps
Linear adjustable separately from 0.01...9999 s
Motor slip compensation
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
Can be suppressed
Switching frequency
2.5...8 kHz with derating factor
2...8 kHz adjustable
Nominal switching frequency
2.5 kHz
Braking to standstill
By DC injection
Brake chopper integrated
False
Maximum Input Current per Phase
156.2 A
Maximum output voltage
480.0 V
Apparent power
112.9 kVA 480 V normal duty)
98.2 kVA 480 V heavy duty)
Maximum transient current
190.3 A 60 s normal duty)
217.5 A 60 s heavy duty)
Network Frequency
50-60 Hz
Prospective line Isc
50 kA
Base load current at high overload
145.0 A
Base load current at low overload
173.0 A
Power dissipation in W
Natural convection 196 W 380 V 2.5 kHz
Forced convection 1585 W 380 V 2.5 kHz
With safety function Safely Limited Speed (SLS)
False
With safety function Safe brake management (SBC/SBT)
False
With safety function Safe Operating Stop (SOS)
False
With safety function Safe Position (SP)
False
With safety function Safe programmable logic
False
With safety function Safe Speed Monitor (SSM)
False
With safety function Safe Stop 1 (SS1)
False
With sft fct Safe Stop 2 (SS2)
False
With safety function Safe torque off (STO)
True
With safety function Safely Limited Position (SLP)
False
With safety function Safe Direction (SDI)
False
Protection type
Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive
Quantity per Set
1
Width
11.4 in (290 mm)
Height
36.3 in (922 mm)
Depth
12.7 in (323 mm)
Net Weight
129.0 lb(US) (58.5 kg)
Environment
Insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
Noise level
62.4 dB 86/188/EEC
Pollution degree
2 IEC 61800-5-1
Vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn 11 ms IEC 60068-2-27
Relative humidity
5…95 % without condensation IEC 60068-2-3
Ambient air temperature for operation
5…122 °F (-15…50 °C) (without derating)
122…140 °F (50…60 °C) (with derating factor)
Operating altitude
<= 3280.84 ft (1000 m) without derating
1000...4800 m with current derating 1 % per 100 m
Operating position
Vertical +/- 10 degree
Product Certifications
ATEX INERIS
TÜV
DNV-GL
UL
ATEX zone 2/22
CSA
Marking
CE
Standards
UL 508C
IEC 61800-3
IEC 61800-3 environment 1 category C2
EN/IEC 61800-3 environment 2 category C3
IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
Maximum THDI
<48 % from 80...100 % of load IEC 61000-3-12
Electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3
Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)
10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)
1.5 mm at 2...13 Hz
Permitted relative humidity (during operation)
Class 3K5 according to EN 60721-3
Volume of cooling air
77932.2 Gal/hr(US) (295 m3/h)
Overvoltage category
III
Regulation loop
Adjustable PID regulator
Noise level
62.4 dB
pollution degree
2
Ambient air transport temperature
-40…158 °F (-40…70 °C)
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Ordering and shipping details
Category
US1CP4E22207
Discount Schedule
CP4E
GTIN
3606480701467
Returnability
Yes
Country of origin
IN
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
18.50 in (47.000 cm)
Package 1 Width
16.93 in (43.000 cm)
Package 1 Length
43.31 in (110.000 cm)
Package 1 Weight
145.505 lb(US) (66.000 kg)