Key Specifications:
• Sensitivity: 8.0 mV/µm (±5%)
• Measurement Range: 0-2.0mm (2000µm)
• Frequency Response: DC to 10kHz
• Temp Range: -40°C to +200°C (peak 250°C)
Extreme-Environment Design:
✓ 11mm heavy-duty probe
✓ M14×1.5 threaded mounting
✓ 6MPa pressure rating
✓ 25g vibration resistance
✓ Optional IP68 protection
Measurement Performance:
Target material: AISI 4140 steel
Linear range: 0.6-1.4mm
Accuracy: ±1% FS
System Integration:
• Compatible with EPRO MMS6000 systems
• High-temp mineral-insulated cable
• ATEX/IECEx options available
Typical Applications:
Gas turbine hot section monitoring
Nuclear plant rotating equipment
Ultra-high-pressure steam turbines