Products
Products
home
PR9268/300-000

Key Specifications:
• Sensitivity: 8.0 mV/µm (±5%)
• Measurement Range: 0-2.0mm (2000µm)
• Frequency Response: DC to 10kHz
• Temp Range: -40°C to +200°C (peak 250°C)

Extreme-Environment Design:
✓ 11mm heavy-duty probe
✓ M14×1.5 threaded mounting
✓ 6MPa pressure rating
✓ 25g vibration resistance
✓ Optional IP68 protection

Measurement Performance:

Target material: AISI 4140 steel

Linear range: 0.6-1.4mm

Accuracy: ±1% FS

System Integration:
• Compatible with EPRO MMS6000 systems
• High-temp mineral-insulated cable
• ATEX/IECEx options available

Typical Applications:

Gas turbine hot section monitoring

Nuclear plant rotating equipment

Ultra-high-pressure steam turbines

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Key Parameters
Electrical Specifications
Sensitivity: 8.0 mV/µm (factory-calibrated, -000 suffix)

Measurement Range: 0 to 2.0 mm (2000 µm)

Output Signal: -2 to -20V DC (linear to gap distance)

Frequency Response: 0 to 10 kHz

Power Supply: -24V DC ±10%

Mechanical & Environmental
Probe Diameter: 11 mm

Thread Size: M14×1.5

Operating Temperature:

Sensor Head: -40°C to +200°C (short-term +250°C)

Cable/Connector: -40°C to +105°C

Vibration Resistance: 25g (50Hz)

Pressure Rating: 6 MPa (60 bar)

Protection Class: IP68 (optional)

Calibration & Target
Target Material: AISI 4140 steel (default calibration)

Linear Range: Middle 60% of full scale (~0.6–1.4mm for 2.0mm range)

Recommended Gap Voltage: -10V DC

Compatibility & Options
Cable: High-temperature mineral-insulated (5m standard)

Works With: EPRO MMS6000 monitoring systems

Compliance: API 670, ATEX/IECEx (optional)

Typical Applications
Gas turbine blade tip clearance

Steam turbine high-pressure section monitoring

Nuclear plant rotating equipment