Products
Products
home
9200-00075

Key Features:

Dual-channel design for simultaneous monitoring of two measurement points

Supports multiple sensor types (eddy current probes, velocity sensors, and accelerometers)

Wide measurement range (0-500µm vibration, 0-50mm/s velocity)

Advanced signal processing with 10kHz sampling rate

Configurable alarm setpoints with delay timers

Multiple output options (4-20mA, ±10V, RS-485/Modbus)

Technical Specifications:

Compliant with API 670 and ISO 7919 standards

IP66/IP67 rated enclosure for harsh environments

Wide operating temperature range (-30°C to +70°C)

24VDC or 100-240VAC power supply options

ATEX/IECEx certified versions available

Typical Applications:

Turbines and compressors in power generation

Critical pumps and motors in oil & gas

Rotating machinery in chemical plants

Predictive maintenance systems

Benefits:

Enhanced machinery protection

Reduced downtime through early fault detection

Flexible integration with control systems

Reliable operation in extreme conditions

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
General Specifications
Model Number: 9200-00075

Type: Dual-channel vibration monitor

Compliance: API 670, ISO 7919 standards

Certifications: ATEX, IECEx (hazardous area versions available)

Input Specifications
Sensor Compatibility:

Eddy current probes (8mm/11mm)

Velocity sensors (4-20mA)

Accelerometers (optional)

Channels: 2 independent monitoring channels

Measurement Ranges:

Vibration: 0-500 µm peak-to-peak (adjustable)

Velocity: 0-50 mm/s RMS

Acceleration: 0-20 g peak

Signal Processing
Frequency Response:

Vibration: 0.5 Hz to 10 kHz

Position: DC to 10 kHz

Sampling Rate: 10 kHz per channel

Filtering: Configurable high-pass/low-pass

Outputs & Communication
Analog Outputs:

4-20 mA (isolated)

±10 VDC

Digital Interfaces:

RS-485 (Modbus RTU)

PROFIBUS-DP (optional)

Relay Outputs:

4 programmable relays

Contact rating: 250VAC/5A

Alarm Functions
Setpoints: Adjustable Warning/Danger levels

Alarm Delay: 0.1-10 seconds configurable

Power Supply
Voltage: 24 VDC ±10% or 100-240 VAC

Consumption: ≤6 W

Environmental Specifications
Operating Temperature: -30°C to +70°C

Enclosure Rating: IP66/IP67

Humidity: 0-95% non-condensing

Mechanical Specifications
Mounting: DIN rail or panel mount

Dimensions: 150 x 100 x 60 mm (typical)

Weight: Approx. 800g

Typical Applications
Turbine and compressor monitoring

Pump and motor protection

Predictive maintenance systems

Integration with DCS/PLC controls