Products
Products
home
MMS6220

Core Function:
Advanced dual-channel monitoring system for critical machinery protection, measuring:
✓ Vibration (velocity/displacement)
✓ Shaft position (via proximity probes)
✓ Rotational speed

Key Features:
• Dual Input Channels – Supports eddy current, velocity, and tachometer signals
• Measurement Ranges:

Vibration: 0-500 µm

Displacement: 0-2.0 mm

Speed: 0-20,000 RPM
• Protective Outputs:

2x 4-20mA analog signals

4x alarm relays (Danger/Warning)

RS-485/Modbus + optional Ethernet

Technical Specs:

Power: 24V DC or 100-240V AC

Operating Temp: -20°C to +70°C

Compliance: API 670, ISO 10816

Typical Applications:

Steam/gas turbine monitoring

Compressor protection systems

Critical pump vibration analysis

Configuration:
Intuitive setup via front panel or EPRO CMS 2000 software

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
General Description
The EPRO MMS6220 is a dual-channel monitoring module designed for vibration, displacement, and speed measurement in critical rotating machinery (turbines, compressors, pumps). It provides real-time monitoring, alarm triggering, and analog/digital outputs for seamless integration with control systems.

Key Parameters
Input Specifications
Channels: 2 independent monitoring channels

Compatible Sensors:

Eddy current probes (e.g., EPRO PR6422, PR6423)

Velocity/acceleration sensors

Tachometer signals (pulse input)

Input Signal Range:

Displacement (Proximity Probes): -2 to -20V DC

Vibration (Velocity): 0.5–20V peak

Speed: 5–15V pulse (magnetic pickup)

Measurement Capabilities
Vibration Monitoring:

Range: 0–500 µm pk-pk (adjustable)

Frequency Band: 10 Hz–1 kHz (ISO 10816 compliant)

Displacement Monitoring:

Range: 0–2.0 mm (configurable)

Accuracy: ±1% of full scale

Speed Monitoring:

Range: 0–20,000 RPM

Resolution: 1 RPM

Outputs & Alarms
Analog Outputs: 2 channels, 4–20 mA (isolated, configurable)

Relay Outputs: 4 programmable relays (SPDT, 250V AC/2A) for Danger/Warning alarms

Communication:

RS-485 (Modbus RTU)

Optional Ethernet or Profibus (depending on variant)

Power & Environmental
Power Supply: 24V DC (±10%) or 100–240V AC

Operating Temperature: -20°C to +70°C

Enclosure Rating: IP20 (panel-mounted)

Display & Interface
Front Panel: LCD with real-time values, bargraphs, and alarm status

Configuration: Keypad or software (EPRO CMS 2000 configuration tool)

Typical Applications
Turbine/compressor protection systems

Bearing health & shaft displacement monitoring

Integration with DCS/PLC systems

Compliance & Certifications
Standards: API 670, ISO 10816

Certifications: CE, ATEX (optional)